Photogrammetric technique applied to anthropometric study of hands.

Abstract:

:Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-40 stereometric camera (for obtaining stereoscopic photographs) and the use of a Wild A7 stereorestitution instrument equipped with digital data acquisition accessories (for obtaining all dimensional information). Three-dimensional data at 21 specific points and for nine specific distances were obtained on each hand of ten persons. Test observations indicate, inter alia, a dimensional accuracy of the order of +/- 0.3 mm obtainable through the working system. Cartographic presentations made in support of the digital data are found to be of help. This also permits to obtain additional data as may be necessary at times. Photogrammetry has the advantage of reducing and maintaining to a minimum all sorts of manipulations necessary in such studies.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Ghosh SK,Poirier F

doi

10.1016/0021-9290(87)90039-x

subject

Has Abstract

pub_date

1987-01-01 00:00:00

pages

729-32

issue

7

eissn

0021-9290

issn

1873-2380

pii

0021-9290(87)90039-X

journal_volume

20

pub_type

杂志文章
  • Estimation of unmeasured ground reaction force data based on the oscillatory characteristics of the center of mass during human walking.

    abstract::To enhance the wearability of portable motion-monitoring devices, the size and number of sensors are minimized, but at the expense of quality and quantity of data collected. For example, owing to the size and weight of low-frequency force transducers, most currently available wearable gait measurement systems provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.046

    authors: Ryu HX,Park S

    更新日期:2018-04-11 00:00:00

  • Energy-conserving impact algorithm for the heel-strike phase of gait.

    abstract::Significant ground reaction forces exceeding body weight occur during the heel-strike phase of gait. The standard methods of analytical dynamics used to solve the impact problem do not accommodate well the heel-strike collision due to the persistent contact at the front foot and presence of contact at the back foot. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00006-3

    authors: Kaplan ML,Heegaard JH

    更新日期:2000-06-01 00:00:00

  • Statistical characterization of piezoelectric coefficient d23 in cow bone.

    abstract::In a newly developed, highly sensitive dilatometer we applied pulsatile electric fields to five dry bone samples cut from mid-tibial sections within a 90 degrees angle from the rear to front axis. Samples of five cows were studied. We measured the piezoelectric coefficient d23 establishing its mean and confidence inte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00021-4

    authors: Aschero G,Gizdulich P,Mango F

    更新日期:1999-06-01 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Effects of intervertebral disc lesion and multifidus muscle resection on the structure of the lumbar intervertebral discs and paraspinal musculature of the rat.

    abstract::The aim of this study was to investigate whether elimination of multifidus muscle in rats causes intervertebral disc (IVD) degeneration similar to that found after IVD lesion. Data were obtained from 36 male Wistar rats randomly assigned to one of three groups: (i) IVD lesion, in which the L4/L5 IVD was stabbed; (ii) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.004

    authors: Maas H,Noort W,Hodges PW,van Dieën J

    更新日期:2018-03-21 00:00:00

  • Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm.

    abstract::An experimental study was carried out on asymmetrical abdominal aortic aneurysm (AAA) to analyse the physiological flows involved. Velocity measurements were performed using particle image velocimetry. Resting and exercise flow rates were investigated in models with rigid and compliant walls to assess the parameters a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.017

    authors: Deplano V,Knapp Y,Bertrand E,Gaillard E

    更新日期:2007-01-01 00:00:00

  • Ultrasound strain mapping of Achilles tendon compressive strain patterns during dorsiflexion.

    abstract::Heel lifts are commonly prescribed to patients with Achilles tendinopathy, yet little is known about the effect on tendon compressive strain. The purposes of the current study were to (1) develop a valid and reliable ultrasound elastography technique and algorithm to measure compressive strain of human Achilles tendon...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.008

    authors: Chimenti RL,Flemister AS,Ketz J,Bucklin M,Buckley MR,Richards MS

    更新日期:2016-01-04 00:00:00

  • Force depression following muscle shortening in sub-maximal voluntary contractions of human adductor pollicis.

    abstract::Mechanical properties of skeletal muscles are often studied for controlled, electrically induced, maximal, or supra-maximal contractions. However, many mechanical properties, such as the force-length relationship and force enhancement following active muscle stretching, are quite different for maximal and sub-maximal,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.002

    authors: Rousanoglou EN,Oskouei AE,Herzog W

    更新日期:2007-01-01 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • Is a joint moment-based cost function associated with preferred cycling cadence?

    abstract::Eight experienced male cyclists (C), eight well-trained male runners (R), and eight less-trained male noncyclists (LT) were tested under multiple cadence and power output conditions to determine: (1) if the cadence at which lower extremity net joint moments are minimized (cost function cadence) was associated with pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00155-4

    authors: Marsh AP,Martin PE,Sanderson DJ

    更新日期:2000-02-01 00:00:00

  • In-vitro results of rapid maxillary expansion on adults compared with finite element simulations.

    abstract::This study was mainly performed to investigate the effects of high maxillary expansion forces on the skull with fresh and thiel-fixed human skulls. The maxillary suture was not weakened except in one experiment. This study compares the strain measured on the zygomatic process of the skull with the results of a finite ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.002

    authors: Boryor A,Hohmann A,Wunderlich A,Geiger M,Kilic F,Sander M,Sander C,Böckers T,Günter Sander F

    更新日期:2010-05-07 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion.

    abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00083-6

    authors: Prilutsky BI,Petrova LN,Raitsin LM

    更新日期:1996-04-01 00:00:00

  • Quantitative associations between osteocyte density and biomechanics, microcrack and microstructure in OVX rats vertebral trabeculae.

    abstract::Osteocytes actively regulate bone modeling and remodeling, direct skeletal mineralization, and regulate calcium/phosphate homeostasis and extracellular matrix metabolism; yet the specific role of osteocytes in maintaining bone structural integrity and strength is unknown. Studies have shown that the density of osteocy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.017

    authors: Ma YL,Dai RC,Sheng ZF,Jin Y,Zhang YH,Fang LN,Fan HJ,Liao EY

    更新日期:2008-01-01 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Sticky chain model for shear response of red blood cells.

    abstract::A sticky chain model has been proposed to describe the unfolding of spectrin network under applied mechanical loads. With the model, the response of a red blood cell (RBC) under static and cyclic shear loading has been predicted, which agrees qualitatively with relevant experimental results. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.028

    authors: Huang GY,Mai YW

    更新日期:2008-08-07 00:00:00

  • Does stretching velocity affect residual force enhancement?

    abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.033

    authors: Fukutani A,Leonard T,Herzog W

    更新日期:2019-05-24 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • Higher critical plaque wall stress in patients who died of coronary artery disease compared with those who died of other causes: a 3D FSI study based on ex vivo MRI of coronary plaques.

    abstract::Mechanical forces play an important role in the rupture of vulnerable plaques. This process is often associated with cardiovascular syndromes, such as heart attack and stroke. In this study, magnetic resonance imaging (MRI)-based models were used to investigate the association between plaque wall stress (PWS) and coro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.007

    authors: Huang X,Yang C,Zheng J,Bach R,Muccigrosso D,Woodard PK,Tang D

    更新日期:2014-01-22 00:00:00

  • Mass properties of the human mandible.

    abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00057-x

    authors: Zhang F,Peck CC,Hannam AG

    更新日期:2002-07-01 00:00:00

  • Compressive strain rate sensitivity of ballistic gelatin.

    abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.008

    authors: Kwon J,Subhash G

    更新日期:2010-02-10 00:00:00

  • A new method for the early diagnosis of brain edema/brain swelling. An experimental study in rabbits.

    abstract::The aim of the present work is to develop a non-destructive, non-invasive technique for the early diagnosis of an oncoming brain edema based on the variation of vibration characteristics of the head system (i.e. eigenfrequency spectrum and modal damping). Besides the theoretical model that supports the basic principle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.001

    authors: Kostopoulos V,Douzinas EE,Kypriades EM,Pappas YZ

    更新日期:2006-01-01 00:00:00

  • Using directional statistics to test hypotheses regarding rigid body attitude: Comparison to univariate and multivariate Cardan angle tests.

    abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109976

    authors: Pataky TC,Challis JH

    更新日期:2020-10-09 00:00:00

  • Regional load bearing of the feline acetabulum.

    abstract:OBJECTIVE:To test if the caudal acetabulum of the cat is unloaded at mid-stance as has been asserted. MATERIALS AND METHODS:A kinematic study of five healthy cats was performed to ascertain the mid-stance angle of the hip joint, and the orientation of the pelvis and femur. Femora and pelves from 10 feline cadavers wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.035

    authors: Beck AL,Pead MJ,Draper E

    更新日期:2005-03-01 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Comparison of the vulnerability risk for positive versus negative atheroma plaque morphology.

    abstract::As plaque develops in arteries two types of remodeling can occur; positive and negative remodeling. Positive remodeling is an outward compensatory remodeling in which the arterial wall grows outward in an attempt to maintain a constant lumen diameter, while negative remodeling is defined as a local shrinkage of vessel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.02.012

    authors: Cilla M,Peña E,Martínez MA,Kelly DJ

    更新日期:2013-04-26 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

    abstract::The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.10.031

    authors: Dong RG,Dong JH,Wu JZ,Rakheja S

    更新日期:2007-01-01 00:00:00

  • Orofacial and thumb-index finger ramp-and-hold isometric force dynamics in young neurotypical adults.

    abstract::The relation among several parameters of the ramp-and-hold isometric force contraction (peak force and dF/dtmax during the initial phase of force recruitment, and the proportion of hold-phase at target) was quantified for the right and left thumb-index finger pinch, and lower lip midline compression in 40 neurotypical...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.031

    authors: Barlow SM,Hozan M,Lee J,Greenwood J,Custead R,Wardyn B,Tippin K

    更新日期:2018-04-27 00:00:00

  • Evidence of isometric function of the flexor hallucis longus muscle in normal gait.

    abstract::Studying mechanics of the muscles spanning multiple joints provides insights into intersegmental dynamics and movement coordination. Multiarticular muscles are thought to function at "near-isometric" lengths to transfer mechanical energy between the adjacent body segments. Flexor hallucis longus (FHL) is a multiarticu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.040

    authors: Kirane YM,Michelson JD,Sharkey NA

    更新日期:2008-01-01 00:00:00