Abstract:
:Studying mechanics of the muscles spanning multiple joints provides insights into intersegmental dynamics and movement coordination. Multiarticular muscles are thought to function at "near-isometric" lengths to transfer mechanical energy between the adjacent body segments. Flexor hallucis longus (FHL) is a multiarticular flexor of the great toe; however, its potential isometric function has received little attention. We used a robotic loading apparatus to investigate FHL mechanics during simulated walking in cadaver feet, and hypothesized that physiological force transmission across the foot can occur with isometric FHL function. The extrinsic foot tendons, stripped of the muscle fibers, were connected to computer-controlled linear actuators. The FHL activity was controlled using force-feedback (FC) based upon electromyographic data from healthy subjects, and subsequently, isometric positional feedback (PC), maintaining the FHL myotendinous junction stationary during simulated walking. Tendon forces and excursions were recorded, as were the strains within the first metatarsal. Forces in the metatarsal and metatarsophalangeal joint were derived from these strains. The FHL tendon excursion under FC was 6.57+/-3.13mm. The forces generated in the FHL tendon, metatarsal and metatarsophalangeal joint with the FHL under isometric PC were not significantly different in pattern from FC. These observations provide evidence that physiological forces could be generated along the great toe with isometric FHL function. A length servo mechanism such as the stretch reflex could likely control the isometric FHL function during in vivo locomotion; this could have interesting implications regarding the conditions of impaired stretch reflex such as spastic paresis and peripheral neuropathies.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Kirane YM,Michelson JD,Sharkey NAdoi
10.1016/j.jbiomech.2008.03.040subject
Has Abstractpub_date
2008-01-01 00:00:00pages
1919-28issue
9eissn
0021-9290issn
1873-2380pii
S0021-9290(08)00166-8journal_volume
41pub_type
杂志文章abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00179-1
更新日期:1999-03-01 00:00:00
abstract::Increased practice difficulty during asymmetrical split-belt treadmill rehabilitation has been shown to improve gait outcomes during retention and transfer tests. However, research in this area has been limited by manual treadmill operation. In the case of variable practice, which requires stride-by-stride changes to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.11.017
更新日期:2016-01-04 00:00:00
abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.008
更新日期:2017-11-07 00:00:00
abstract::Poisson's ratio has not been experimentally measured earlier for meniscus in compression. It is however an important intrinsic material property needed in biomechanical analysis and computational models. In this study, equilibrium Poisson's ratio of bovine meniscus (n = 6) was determined experimentally by combining st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.001
更新日期:2018-08-22 00:00:00
abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.04.015
更新日期:2006-01-01 00:00:00
abstract::Bone fracture reduction and bone axial dynamization are important operations which effectiveness can be further enhanced by the use of a unilateral external fixator. By design, axial dynamization can be performed through reciprocating one of its translational joints. However, non-axial dynamization may occur after cor...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.05.002
更新日期:2009-08-25 00:00:00
abstract::Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect are...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.03.019
更新日期:2013-05-31 00:00:00
abstract::The motor module hypothesis in motor control proposes that the nervous system can simplify the problem of controlling a large number of muscles in human movement by grouping muscles into a smaller number of modules. Here, we tested one prediction of the modular organization hypothesis by examining whether there is pre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.006
更新日期:2016-03-21 00:00:00
abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.010
更新日期:2018-02-08 00:00:00
abstract::This paper presents a general method for simulating the movement of the lower extremity during human walking. It is based upon two separate algorithms: one for single support (an open kinematic chain), and the other for the double support phase (a closed-loop linkage). Central to each of these is the recursive Newton-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90250-3
更新日期:1988-01-01 00:00:00
abstract::A computational model of adaptive bone remodelling is formulated as an optimization problem of instantaneous changes in microstructure that minimize a functional describing the structure quality rate. Microstructure is locally described by a set of scalar geometric parameters. Macroscopic (continuum) elastic propertie...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.09.045
更新日期:2010-02-10 00:00:00
abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.024
更新日期:2018-03-01 00:00:00
abstract::Determination of contact areas in diarthrodial joints is necessary for understanding the state of stress within the articular cartilage layers and the supporting bony structures. The present study describes the use of a stereophotogrammetry (SPG) system [Huiskes et al., J. Biomechanics 18, 559-570 (1985) and Ateshian ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90038-8
更新日期:1994-01-01 00:00:00
abstract::Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.10.009
更新日期:2019-01-03 00:00:00
abstract::The contact nature of American football has made head acceleration exposure a concern. We aimed to quantify the head kinematics associated with direct helmet contact and inertial head loading events in collegiate-level American football. A cohort of collegiate-level players were equipped with instrumented mouthguards ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109969
更新日期:2020-09-18 00:00:00
abstract::Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90262-3
更新日期:1994-07-01 00:00:00
abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.009
更新日期:2014-08-22 00:00:00
abstract::The skeleton consists of a series of elements with a variety of functions. In locations where shape or protection are of prime importance the bone's architecture is achieved during growth under direct genetic control. In locations where resistance to repetitive loading is important only the general form of the bone wi...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/0021-9290(87)90026-1
更新日期:1987-01-01 00:00:00
abstract::This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90331-g
更新日期:1991-01-01 00:00:00
abstract::This numerical study assesses the influence of an oversized humeral hemiprosthesis with a larger medial offset on the mechanics of the shoulder with cuff tear arthropathy (CTA). Shoulder elevation in the scapular plane is performed, and a Seebauer Type IIa CTA is simulated: a massive rotator cuff tear, a proximal and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.11.021
更新日期:2013-02-22 00:00:00
abstract::The topographical distributions of the zonal properties of articular cartilage over the medial tibia from an experimental osteoarthritis (OA) model were evaluated as a function of external loading by microscopic Magnetic Resonance Imaging (µMRI). T2 relaxation times and cartilage thicknesses were measured at 17.6 µm r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.011
更新日期:2015-10-15 00:00:00
abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.10.017
更新日期:2014-01-03 00:00:00
abstract::Accurate knowledge of extraocular muscle (EOM) tension is important for the diagnosis of and surgical planning for strabismus, such as choosing which eye to operate or determining the amount of muscle displacement. Previous evaluations of passive EOM tension have relied extensively on the experience and skill of ophth...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109955
更新日期:2020-08-26 00:00:00
abstract::Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.019
更新日期:2010-03-03 00:00:00
abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00040-7
更新日期:1997-08-01 00:00:00
abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00145-2
更新日期:2001-12-01 00:00:00
abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90092-6
更新日期:1982-01-01 00:00:00
abstract::The aligned axonal fiber bundles in white matter make it suitable to be modeled as a transversely isotropic material. Recent experimental studies have shown that a minimal form, nearly incompressible transversely isotropic (MITI) material model, is capable of describing mechanical anisotropy of white matter. Here, we ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.03.025
更新日期:2017-05-24 00:00:00
abstract::A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00178-7
更新日期:2003-11-01 00:00:00
abstract::When balance is disturbed, location of the center of pressure (COP) contributes to a person's ability to recover from a perturbation. This study investigated COP control prior to first step lift-off (FSLO) during lateral perturbations in older non-fallers and fallers. 38 non-fallers and 16 fallers received lateral wai...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.012
更新日期:2015-04-13 00:00:00