Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

Abstract:

:None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Clément J,Raison M,Rouleau DM

doi

10.1016/j.jbiomech.2017.12.010

subject

Has Abstract

pub_date

2018-02-08 00:00:00

pages

58-64

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(17)30717-0

journal_volume

68

pub_type

杂志文章
  • An activatable molecular spring reduces muscle tearing during extreme stretching.

    abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.016

    authors: Leonard TR,Joumaa V,Herzog W

    更新日期:2010-11-16 00:00:00

  • In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament.

    abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109996

    authors: Connizzo BK,Naveh GRS

    更新日期:2020-10-09 00:00:00

  • Mechanical stretch inhibits mesenchymal stem cell adipogenic differentiation through TGFβ1/Smad2 signaling.

    abstract::Mesenchymal stem cells (MSCs) are the common precursors of several functionally disparate cell lineages. A plethora of chemical and physical stimuli contribute to lineage decisions and guidance, including mechanical stretch concomitant with physical movement. Here, we examined how stretch regulates MSC differentiation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.013

    authors: Li R,Liang L,Dou Y,Huang Z,Mo H,Wang Y,Yu B

    更新日期:2015-10-15 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Stress relaxation of human ankles is only minimally affected by knee and ankle angle.

    abstract::Comprehensive characterization of stress relaxation in musculotendinous structures is needed to create robust models of viscoelastic behavior. The commonly used quasi-linear viscoelastic (QLV) theory requires that the relaxation response be independent of tissue strain (length). This study aims to characterize stress ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.017

    authors: Tian M,Hoang PD,Gandevia SC,Bilston LE,Herbert RD

    更新日期:2010-03-22 00:00:00

  • Force depression following muscle shortening in sub-maximal voluntary contractions of human adductor pollicis.

    abstract::Mechanical properties of skeletal muscles are often studied for controlled, electrically induced, maximal, or supra-maximal contractions. However, many mechanical properties, such as the force-length relationship and force enhancement following active muscle stretching, are quite different for maximal and sub-maximal,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.002

    authors: Rousanoglou EN,Oskouei AE,Herzog W

    更新日期:2007-01-01 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Sensitivity of a Hill-based muscle model to perturbations in model parameters.

    abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.005

    authors: Scovil CY,Ronsky JL

    更新日期:2006-01-01 00:00:00

  • Comparison of biomechanical failure criteria for abdominal aortic aneurysm.

    abstract::Medical doctors consider a surgery option for the expanding abdominal aortic aneurysm (AAA) when its maximum diameter reaches 5.5cm. This simple geometrical criterion may possibly underestimate the risks of rupture of small aneurysms as well as overestimate the risks of rupture of large aneurysms. Biomechanical criter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.024

    authors: Volokh KY

    更新日期:2010-07-20 00:00:00

  • Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body.

    abstract::Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10 and 20-kg wide and ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2008.10.013

    authors: Faber GS,Kingma I,Bakker AJ,van Dieën JH

    更新日期:2009-01-05 00:00:00

  • Fatigue damage of human tendons.

    abstract::The study was designed to examine the effects of partial fatigue on specific mechanical parameters which characterise human tendons in vitro. Specimens prepared from 12 intact Extensor digitorum longus tendons of the foot were subjected to partial fatigue, equivalent to 25% of the median fatigue life, by a cyclic squa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00177-4

    authors: Schechtman H,Bader DL

    更新日期:2002-03-01 00:00:00

  • The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

    abstract::Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.034

    authors: Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

    更新日期:2015-06-01 00:00:00

  • The three-dimensional determination of internal loads in the lower extremity.

    abstract::A three-dimensional model of the lower limb containing 47 muscles was developed to study the differences between a two- and three-dimensional approach for determining internal loads, the role of the dynamic joint representation, and the behavior of different load-bearing criteria in walking and running. The problem of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00089-4

    authors: Glitsch U,Baumann W

    更新日期:1997-11-01 00:00:00

  • Nuclear mechanotransduction: response of the lamina to extracellular stress with implications in aging.

    abstract::Mechnotransduction, the phenomenon by which cells respond to applied force, is necessary for normal cell processes and is implicated in the pathology of several diseases including atherosclerosis. The exact mechanisms which govern how forces can affect gene expression have not been determined, but putative direct forc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.024

    authors: Philip JT,Dahl KN

    更新日期:2008-11-14 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • Higher critical plaque wall stress in patients who died of coronary artery disease compared with those who died of other causes: a 3D FSI study based on ex vivo MRI of coronary plaques.

    abstract::Mechanical forces play an important role in the rupture of vulnerable plaques. This process is often associated with cardiovascular syndromes, such as heart attack and stroke. In this study, magnetic resonance imaging (MRI)-based models were used to investigate the association between plaque wall stress (PWS) and coro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.007

    authors: Huang X,Yang C,Zheng J,Bach R,Muccigrosso D,Woodard PK,Tang D

    更新日期:2014-01-22 00:00:00

  • Stepping over an obstacle increases the motions and moments of the joints of the trailing limb in young adults.

    abstract::Tripping over obstacles is the most frequently mentioned causes of falls. Thus, this study was performed to test the hypotheses that when crossing obstacles, toe-obstacle clearance and the three-dimensional motions and moments at the hip, knee, and ankle of the trailing limb (limb crossing the obstacle last) increase ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00161-3

    authors: Chou LS,Draganich LF

    更新日期:1997-04-01 00:00:00

  • The force resulting from the action of mono- and biarticular muscles in a limb.

    abstract::Human and animal limbs can be modelled as a chain of segments connected at joints. For a static limb, the force exerted at the endpoint due to the force of a single muscle has been calculated. It turns out that there are marked differences in the action of mono- vs. biarticular muscles. Monoarticular muscles produce a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00056-2

    authors: Hof AL

    更新日期:2001-08-01 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • An analysis of the complete strain field within Flexercell membranes.

    abstract::The purpose of the current investigation was to use finite element analysis to quantify the complete strain field for the membranes of the Flexercell apparatus, a device extensively used to study the effects of mechanical loading on cultured cells. Four vacuum pressure simulations were run for the membrane for both th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.022

    authors: Vande Geest JP,Di Martino ES,Vorp DA

    更新日期:2004-12-01 00:00:00

  • Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

    abstract::The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00065-c

    authors: Cholewicki J,McGill SM,Norman RW

    更新日期:1995-03-01 00:00:00

  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • The influence of strain rate on adaptive bone remodelling.

    abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90092-6

    authors: O'Connor JA,Lanyon LE,MacFie H

    更新日期:1982-01-01 00:00:00

  • Sensitivity analysis of muscle properties and impact parameters on head injury risk in American football.

    abstract::Head injuries frequently occur in American football and other contact sports. Uncertainty on the effects of cervical muscle properties on head injury risk may be due to the limitations of previous observational studies. This simulation study employs a musculoskeletal model of the head and neck to investigate the effec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109411

    authors: Mortensen JD,Vasavada AN,Merryweather AS

    更新日期:2020-02-13 00:00:00

  • The transmission of translational seat vibration to the head--II. Horizontal seat vibration.

    abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90170-4

    authors: Paddan GS,Griffin MJ

    更新日期:1988-01-01 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study.

    abstract::Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.006

    authors: Completo A,Fonseca F,Simões JA

    更新日期:2008-01-01 00:00:00

  • Articular contact in a three-dimensional model of the knee.

    abstract::This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different mathematical conta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90019-j

    authors: Blankevoort L,Kuiper JH,Huiskes R,Grootenboer HJ

    更新日期:1991-01-01 00:00:00

  • Improving the clinical efficiency of T2(*) mapping of ligament integrity.

    abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.037

    authors: Biercevicz AM,Walsh EG,Murray MM,Akelman MR,Fleming BC

    更新日期:2014-07-18 00:00:00

  • Walking at the preferred stride frequency maximizes local dynamic stability of knee motion.

    abstract::Healthy humans display a preference for walking at a stride frequency dependent on the inertial properties of their legs. Walking at preferred stride frequency (PSF) is predicted to maximize local dynamic stability, whereby sensitivity to intrinsic perturbations arising from natural variability inherent in biological ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.012

    authors: Russell DM,Haworth JL

    更新日期:2014-01-03 00:00:00