The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

Abstract:

:Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial meniscus. However, this model did not provide information on the functional importance of these geometry characteristics. Therefore, in this study finite element simulations were performed to determine the influence of anatomically-based meniscal implant size and shape variations on knee cartilage contact pressures. Finite element simulations of the knee joint were performed for a total medial meniscectomy, an allograft, the average implant geometry, six implant sizes and ten shape variations. The geometries of the allograft and all implant variations were based on the meniscus SSM. Cartilage contact pressures and implant tensile strains were evaluated in full extension under 1200N of axial compression. The average implant induced cartilage peak pressures intermediate between the allograft and meniscectomy and also reduced the cartilage area subjected to pressures >5MPa compared to the meniscectomy. The smaller implant sizes resulted in lower cartilage peak pressures and compressive strains than the allograft, yet high implant tensile strains were observed. Shape modes 2, 3 and 6 affected the cartilage contact stresses but to a lesser extent than the size variations. Shape modes 4 and 5 did not result in changes of the cartilage stress levels. The present study indicates that cartilage contact mechanics are more sensitive to implant size than to implant shape. Down-sizing the implant resulted in more favorable contact mechanics, but caused excessive material strains. Further evaluations are necessary to balance cartilage contact pressures and material strains to ensure cartilage protection and longevity of the implant.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

doi

10.1016/j.jbiomech.2015.02.034

subject

Has Abstract

pub_date

2015-06-01 00:00:00

pages

1427-35

issue

8

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(15)00124-4

journal_volume

48

pub_type

杂志文章
  • Ex-vivo observation of calcification process in chick tibia slice: Augmented calcification along collagen fiber orientation in specimens subjected to static stretch.

    abstract::Bone formation through matrix synthesis and calcification in response to mechanical loading is an essential process of the maturation in immature animals, although how mechanical loading applied to the tissue increases the calcification and improves mechanical properties, and which directions the calcification progres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.024

    authors: Maeda E,Ichikawa K,Murase K,Nagayama K,Matsumoto T

    更新日期:2018-09-10 00:00:00

  • Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

    abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.043

    authors: Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

    更新日期:2016-08-16 00:00:00

  • A theoretical study of the influence of bone maturation rate on surface remodeling predictions: idealized models.

    abstract::The use of a finite element based computational method, RFEM3D, is described for the study of strain-induced bone remodeling. The purpose of the research is to find the potential influence on the predictions of surface bone remodeling when various models for the maturation of newly deposited bone are used. A parameter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90015-u

    authors: Hart RT

    更新日期:1990-01-01 00:00:00

  • Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties.

    abstract::High-resolution voxel-based finite element software, such as FEEBE developed at the NCBES, is widely used for studying trabecular bone at the micro-scale. A new approach to determine heterogeneous bone tissue material properties for computational models was proposed in this study. The specimen-specific range of tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.014

    authors: Harrison NM,McDonnell PF,O'Mahoney DC,Kennedy OD,O'Brien FJ,McHugh PE

    更新日期:2008-08-07 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal.

    abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.035

    authors: Cacciari LP,Pássaro AC,Amorim AC,Geuder M,Sacco ICN

    更新日期:2017-06-14 00:00:00

  • Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

    abstract::A truss structure was recently introduced as an interbody fusion cage. As a truss system, some of the connected elements may be in a state of compression and others in tension. This study aimed to quantify both the mean and variance of strut strains in such an implant when loaded in a simulated fusion condition with v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.051

    authors: Caffrey JP,Cory E,Wong VW,Masuda K,Chen AC,Hunt JP,Ganey TM,Sah RL

    更新日期:2016-12-08 00:00:00

  • The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

    abstract::Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.021

    authors: Defrate LE,van der Ven A,Boyer PJ,Gill TJ,Li G

    更新日期:2006-01-01 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • Straining of the intact and fractured proximal humerus under physiological-like loading.

    abstract::Surgical treatment of proximal humeral fractures remains challenging in elderly patients, primarily due to insufficient implant fixation. Both bone quality and physiological-like loading conditions are commonly overlooked during pre-clinical in vitro evaluation. However, this knowledge is necessary in order to improve...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00212-4

    authors: Maldonado ZM,Seebeck J,Heller MO,Brandt D,Hepp P,Lill H,Duda GN

    更新日期:2003-12-01 00:00:00

  • A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: Potential application to hypercompliant soft tissues.

    abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.019

    authors: Olberding JE,Francis Suh JK

    更新日期:2006-01-01 00:00:00

  • A holistic approach to study the temporal variability in gait.

    abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.008

    authors: Federolf P,Tecante K,Nigg B

    更新日期:2012-04-30 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • The nature of the stabilizing functions of skeletal muscles.

    abstract::The paper defines the term coordination interval (CI), suggesting that it should replace the term electromechanical delay (EMD), if this parameter is determined in vivo for a muscle functioning in a biomechanical system with considerable mobility, but not in a kinematic pair with one degree of rotational freedom (DOF)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90211-9

    authors: Kornecki S,Zschorlich V

    更新日期:1994-02-01 00:00:00

  • Adaptational responses in dynamic stability during disturbed walking in the elderly.

    abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.025

    authors: Bierbaum S,Peper A,Karamanidis K,Arampatzis A

    更新日期:2010-08-26 00:00:00

  • Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

    abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.013

    authors: Pantall A,Gregor RJ,Prilutsky BI

    更新日期:2012-05-11 00:00:00

  • Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions.

    abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.023

    authors: Chevalier Y,Matsuura M,Krüger S,Fleege C,Rickert M,Rauschmann M,Schilling C

    更新日期:2018-03-21 00:00:00

  • A mathematical model to investigate the effects of intravenous fluid administration and fluid loss.

    abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.002

    authors: Rosalina TT,Bouwman RA,van Sambeek MRHM,van de Vosse FN,Bovendeerd PHM

    更新日期:2019-05-09 00:00:00

  • Studies of human locomotion: past, present and future.

    abstract::The study of human locomotion and its applications are examined from a historical viewpoint. Several critical steps in the advancement of the discipline are considered in the context of addressing a particular need to answer fundamental questions regarding the process of human locomotion. In addition, changes in the m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(00)00061-0

    authors: Andriacchi TP,Alexander EJ

    更新日期:2000-10-01 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Cross-sectional structural parameters from densitometry.

    abstract::Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section alo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00220-2

    authors: Cleek TM,Whalen RT

    更新日期:2002-04-01 00:00:00

  • Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    abstract::Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and int...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.028

    authors: Boser QA,Valevicius AM,Lavoie EB,Chapman CS,Pilarski PM,Hebert JS,Vette AH

    更新日期:2018-04-27 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Isolated changes in femoral version do not alter intra-articular contact mechanics in cadaveric hips.

    abstract::Abnormal femoral version is a deformity in the angle between the femoral neck and the transcondylar axis of the knee. Both femoral anteversion and retroversion alter passive and active rotation of the hip and are associated with intra-articular or extra-articular impingement. However, little is known about the effect ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109891

    authors: Meyer AM,Thomas-Aitken HD,Brouillette MJ,Westermann RW,Goetz JE

    更新日期:2020-08-26 00:00:00

  • Biaxial anisotropy of dog carotid artery: estimation of circumferential elastic modulus.

    abstract::Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90011-4

    authors: Dobrin PB

    更新日期:1986-01-01 00:00:00

  • Three-dimensional osseo-ligamentous model of the thorax representing initiation of scoliosis by asymmetric growth.

    abstract::A biomechanical model of the human thorax was constructed to investigate how asymmetric growth of the thorax might initiate spinal lateral curvature and axial rotation as seen in scoliosis deformities. Geometric data specifying nodal points of the model were taken from stereo-radiographs of an adolescent subject. An i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90051-4

    authors: Stokes IA,Laible JP

    更新日期:1990-01-01 00:00:00

  • Tensile stress-strain characteristics of the human meniscal material.

    abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00081-e

    authors: Tissakht M,Ahmed AM

    更新日期:1995-04-01 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P