Straining of the intact and fractured proximal humerus under physiological-like loading.

Abstract:

:Surgical treatment of proximal humeral fractures remains challenging in elderly patients, primarily due to insufficient implant fixation. Both bone quality and physiological-like loading conditions are commonly overlooked during pre-clinical in vitro evaluation. However, this knowledge is necessary in order to improve surgical treatment of the proximal humerus and the mechanical behavior of implants, particularly in patients with complex fractures and weak bone stock. We hypothesize that the bone quality has a high influence on the bone straining, independent of the arm position. The goal of this study was to determine the straining of the intact and fractured proximal humerus under physiological-like loading conditions. Furthermore, the impact of augmentation on tissue straining was evaluated. Two representative humeri were selected for this study, one osteoporotic and one reference quality, and scanned using both QCT and DEXA (average DEXA value=0.26 and 0.49 g/cm2 respectively). Subcaptial defects were generated, then stabilized with a plate prior to mechanical stiffness testing. From the QCT data, finite element models were generated and the in vitro stiffness tests analytically simulated. Under physiological-like loading conditions, the straining of the bone and implant were analyzed for 0 degrees, 90 degrees forward flexion, and 90 degrees abduction. Maximal strain values were found for the intact and fractured bone at 90 degrees abduction. This study demonstrates that the straining in a fractured bone of poor quality leads to considerably higher bone strains (up to +30%) than in a more healthy bone. Augmentation of a central void under physiological-like loading with commercial cement led to mechanical failure at the bone-cement interface. New concepts for the surgical treatment of complex fractures of the proximal humerus should take bone distribution into account and thereby allow effective treatment of fractures in osteoporotic patients. The ultimate salvage procedure of augmentation has mechanical limitations as long as current cement materials are used in osteoporotic patients.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Maldonado ZM,Seebeck J,Heller MO,Brandt D,Hepp P,Lill H,Duda GN

doi

10.1016/s0021-9290(03)00212-4

keywords:

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

1865-73

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021929003002124

journal_volume

36

pub_type

杂志文章
  • The range of axial rotation of the glenohumeral joint.

    abstract::There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.007

    authors: Southgate DF,Hill AM,Alexander S,Wallace AL,Hansen UN,Bull AM

    更新日期:2009-06-19 00:00:00

  • A method to estimate the elastic properties of the extracellular matrix of articular cartilage.

    abstract::In this work we propose a method to estimate the elastic properties of the extracellular matrix of articular cartilage, once the elastic properties of the chondrocytes and the whole tissue are known. The influence of the elastic properties of the tissue and the cell concentration on the estimated elastic properties of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00280-x

    authors: Federico S,Herzog W,Wu JZ,La Rosa G

    更新日期:2004-03-01 00:00:00

  • Does weightlifting increase residual force enhancement?

    abstract::The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions du...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.017

    authors: Siebert T,Kurch D,Blickhan R,Stutzig N

    更新日期:2016-07-05 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Formation and travel of vortices in model ventricles: application to the design of skeletal muscle ventricles.

    abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00065-8

    authors: Shortland AP,Black RA,Jarvis JC,Henry FS,Iudicello F,Collins MW,Salmons S

    更新日期:1996-04-01 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Shear strength and toughness of trabecular bone are more sensitive to density than damage.

    abstract::Microdamage occurs in trabecular bone under normal loading, which impairs the mechanical properties. Architectural degradation associated with osteoporosis increases damage susceptibility, resulting in a cumulative negative effect on the mechanical properties. Treatments for osteoporosis could be targeted toward incre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.002

    authors: Garrison JG,Gargac JA,Niebur GL

    更新日期:2011-11-10 00:00:00

  • Biaxial mechanical testing of human sclera.

    abstract::The biomechanical environment of the optic nerve head (ONH), of interest in glaucoma, is strongly affected by the biomechanical properties of sclera. However, there is a paucity of information about the variation of scleral mechanical properties within eyes and between individuals. We thus used biaxial testing to meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.031

    authors: Eilaghi A,Flanagan JG,Tertinegg I,Simmons CA,Wayne Brodland G,Ross Ethier C

    更新日期:2010-06-18 00:00:00

  • In-vitro results of rapid maxillary expansion on adults compared with finite element simulations.

    abstract::This study was mainly performed to investigate the effects of high maxillary expansion forces on the skull with fresh and thiel-fixed human skulls. The maxillary suture was not weakened except in one experiment. This study compares the strain measured on the zygomatic process of the skull with the results of a finite ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.002

    authors: Boryor A,Hohmann A,Wunderlich A,Geiger M,Kilic F,Sander M,Sander C,Böckers T,Günter Sander F

    更新日期:2010-05-07 00:00:00

  • Understanding muscle coordination of the human leg with dynamical simulations.

    abstract::Muscles coordinate multijoint motion by generating forces that cause reaction forces throughout the body. Thus, a muscle can redistribute existing segmental energy by accelerating some segments and decelerating others. In the process, a muscle may also produce or absorb energy, in which case its summed energetic effec...

    journal_title:Journal of biomechanics

    pub_type:

    doi:10.1016/s0021-9290(02)00046-5

    authors: Zajac FE

    更新日期:2002-08-01 00:00:00

  • Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty.

    abstract::Squeaking is reported for ceramic-on-ceramic hip arthroplasty, and risk factors leading to this phenomenon have been investigated empirically in the past, this way giving hints to when this phenomenon occurs. The aim of this study is to present an experimentally validated explanation for the dynamical mechanism underl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.025

    authors: Weiss C,Hothan A,Huber G,Morlock MM,Hoffmann NP

    更新日期:2012-01-10 00:00:00

  • Mechanical response of a simple finite element model of the intervertebral disc under complex loading.

    abstract::A simple axisymmetric finite element model of a human spine segment containing two adjacent vertebrae and the intervening intervertebral disc was constructed. The bodies and disc were modeled by three substructures; one to represent each of the vertebral bodies, the annulus fibrosus, and the nucleus pulposus. A semi-a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90128-3

    authors: Spilker RL,Daugirda DM,Schultz AB

    更新日期:1984-01-01 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • Quantitative assessment of trunk deformation during running.

    abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.019

    authors: Kudo S,Fujimoto M,Isaka T,Nagano A

    更新日期:2017-07-05 00:00:00

  • A sensitive data analysis approach for detecting changes in dynamic postural stability.

    abstract::Understanding the mechanisms of instability can aid in reducing fall risk. As a sensitive measure of fall risk, the distance between the center of pressure (COP) and center of mass (COM) is currently assessed through discrete points assumed to represent physiological important fall mechanisms. However, it is unclear i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109899

    authors: Moudy SC,Patterson RM,Bugnariu N

    更新日期:2020-07-17 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Separating brain motion into rigid body displacement and deformation under low-severity impacts.

    abstract::The relative motion of the brain with respect to the skull has been widely studied to investigate brain injury mechanisms under impacts, but the motion patterns are not yet thoroughly understood. This work analyzes brain motion patterns using the most recent and advanced experimental relative brain/skull motion data c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2006.06.018

    authors: Zou H,Schmiedeler JP,Hardy WN

    更新日期:2007-01-01 00:00:00

  • Confocal-based cell-specific finite element modeling extended to study variable cell shapes and intracellular structures: the example of the adipocyte.

    abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.012

    authors: Or-Tzadikario S,Gefen A

    更新日期:2011-02-03 00:00:00

  • The selection of a standard convention for analyzing gait data based on the analysis of relevant biomechanical factors.

    abstract::The gait cycle is usually analyzed using one of two conventions: heel contact initiates the cycle and stance is followed by swing phases or toe-off initiates the cycle and swing then stance phases are analyzed. The purpose of the study is to demonstrate that based on a consideration of relevant biomechanical measures,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90025-6

    authors: DeVita P

    更新日期:1994-04-01 00:00:00

  • Long-term implant fixation and stress-shielding in total hip replacement.

    abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.12.021

    authors: Sumner DR

    更新日期:2015-03-18 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • How muscle architecture and moment arms affect wrist flexion-extension moments.

    abstract::The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphic model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-exte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00015-8

    authors: Gonzalez RV,Buchanan TS,Delp SL

    更新日期:1997-07-01 00:00:00

  • Lumbar spinal muscle activation synergies predicted by multi-criteria cost function.

    abstract::The hypothesis that control of lumbar spinal muscle synergies is biomechanically optimized was studied by comparing EMG data with an analytical model with a multi-component cost function that could include (1) trunk displacements, (2) intervertebral displacements, (3) intervertebral forces; (4) sum of cubed muscle str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00034-3

    authors: Stokes IA,Gardner-Morse M

    更新日期:2001-06-01 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00

  • Sensitivity of flow patterns in aneurysms on the anterior communicating artery to anatomic variations of the cerebral arterial network.

    abstract::Recent studies raised increasing concern about the reliability of computer models in reproducing in vivo hemodynamics in cerebral aneurysms. Boundary condition problem is among the most frequently addressed issues since three-dimensional (3-D) modeling is usually restricted to local arterial segments. The present stud...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.031

    authors: Liang F,Liu X,Yamaguchi R,Liu H

    更新日期:2016-11-07 00:00:00

  • Hemodynamic effects of pulsatile unloading of left ventricular assist devices (LVAD) on intraventricular flow and ventricular stress.

    abstract::The role of pulsatile unloading in hemodynamic changes in intraventricular flow and ventricular wall stress remains unknown. In this study, a finite element model of the left ventricle (LV) is proposed to calculate the mechanical response. The constitutive model of the LV is composed of a quasi-incompressible transver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109425

    authors: Gu K,Guan Z,Chang Y,Gao B,Ling Y,Song Z,Wan F

    更新日期:2020-04-16 00:00:00

  • Sensitivity of ACL volume and T2∗ relaxation time to magnetic resonance imaging scan conditions.

    abstract::Anterior cruciate ligament (ACL) volume and T2∗ relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T2∗ relaxati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.03.010

    authors: Beveridge JE,Walsh EG,Murray MM,Fleming BC

    更新日期:2017-05-03 00:00:00

  • Internal strain gradients quantified in bone under load using high-energy X-ray scattering.

    abstract::High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.015

    authors: Stock SR,Yuan F,Brinson LC,Almer JD

    更新日期:2011-01-11 00:00:00

  • Femoral neck bone adaptation to weight-bearing physical activity by computational analysis.

    abstract::Individual differences in bone mass distribution at the proximal femur may be determined by daily weight-bearing physical activity (PA) since bone self-adapts according to the mechanical loads that is submitted. The aim of this study was to analyse computationally the effect of different weight-bearing PA types in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.031

    authors: Machado MM,Fernandes PR,Cardadeiro G,Baptista F

    更新日期:2013-09-03 00:00:00