Cross-sectional structural parameters from densitometry.

Abstract:

:Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section along the length of the scan. Various aluminum phantoms were used to examine scanner characteristics to develop the highest accuracy possible for in vitro non-invasive analysis of cross-sectional properties. Factors considered included X-ray photon energy, initial scan orientation, the angle spanned by the three scans (included angle), and I(min)/I(max) ratios. Principal moments of inertia were accurate to within +/-3.1% and principal angles were within +/-1 degrees of the expected value for phantoms scanned with included angles of 60 degrees and 90 degrees at the higher X-ray photon energy (140 kVp). Low standard deviations in the error (0.68-1.84%) also indicate high precision of calculated measurements with these included angles. Accuracy and precision decreased slightly when the included angle was reduced to 30 degrees. The method was then successfully applied to a pair of excised cadaveric tibiae. The accuracy and insensitivity of the algorithms to cross-sectional shape and changing isotropy (I(min)/I(max)) values when various included angles are used make this technique viable for future in vivo studies.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Cleek TM,Whalen RT

doi

10.1016/s0021-9290(01)00220-2

keywords:

subject

Has Abstract

pub_date

2002-04-01 00:00:00

pages

511-6

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021929001002202

journal_volume

35

pub_type

杂志文章
  • Simple method for measuring center of mass work during field running.

    abstract::The purpose of this study was to propose and validate a new simple method for calculation of center of mass work during field running, in order to avoid the use of costly and inconvenient measurement devices. This method relies on spring-mass model and measurements of average horizontal velocity, and contact and fligh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109369

    authors: Devise M,Rossi J,Théveniau N,Belli A

    更新日期:2019-12-03 00:00:00

  • Evaluation of brain-skull interface modelling approaches on the prediction of acute subdural hematoma in the elderly.

    abstract::Acute subdural hematoma (ASDH) in the elderly is currently a matter of concern due to the growing number of the aging population and their higher incident rate compared to the younger adults. Computational head models that can replicate this age-related injury pattern are valuable tools to help addressing this concern...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109787

    authors: Zhou Z,Li X,Kleiven S

    更新日期:2020-05-22 00:00:00

  • A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: Potential application to hypercompliant soft tissues.

    abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.019

    authors: Olberding JE,Francis Suh JK

    更新日期:2006-01-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: transient simulations.

    abstract::This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.034

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2006-01-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • Femoral neck bone adaptation to weight-bearing physical activity by computational analysis.

    abstract::Individual differences in bone mass distribution at the proximal femur may be determined by daily weight-bearing physical activity (PA) since bone self-adapts according to the mechanical loads that is submitted. The aim of this study was to analyse computationally the effect of different weight-bearing PA types in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.031

    authors: Machado MM,Fernandes PR,Cardadeiro G,Baptista F

    更新日期:2013-09-03 00:00:00

  • Classification of errors in locating a rigid body.

    abstract::This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimension...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00008-5

    authors: Ball KA,Pierrynowski MR

    更新日期:1996-09-01 00:00:00

  • Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises.

    abstract::A subject, who had undergone surgery to replace one hip joint and the proximal half of the femur with an instrumented titanium implant, performed brief exercises whilst simultaneous measurements were made of compressive axial force in the implant using short-range wireless telemetry, ground reactions using a Kistler f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00043-7

    authors: Bassey EJ,Littlewood JJ,Taylor SJ

    更新日期:1997-03-01 00:00:00

  • Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing.

    abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.026

    authors: Knothe UR,Dolejs S,Matthew Miller R,Knothe Tate ML

    更新日期:2010-10-19 00:00:00

  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00

  • How muscle architecture and moment arms affect wrist flexion-extension moments.

    abstract::The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphic model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-exte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00015-8

    authors: Gonzalez RV,Buchanan TS,Delp SL

    更新日期:1997-07-01 00:00:00

  • Biomechanical analysis of fluid percussion model of brain injury.

    abstract::Fluid percussion injury (FPI) is a widely used experimental model for studying traumatic brain injury (TBI). However, little is known about how the brain mechanically responds to fluid impacts and how the mechanical pressures/strains of the brain correlate to subsequent brain damage for rodents during FPI. Hence, we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.004

    authors: Mao H,Lu L,Bian K,Clausen F,Colgan N,Gilchrist M

    更新日期:2018-08-22 00:00:00

  • Characterisation of vortex shedding in vascular anastomosis models using pulsed Doppler ultrasound.

    abstract::Vortex shedding at vascular anastomoses were investigated in vitro using a 20 MHz pulsed-wave Doppler velocimeter. Centreline velocity measurements were made at various axial distances in simplified polyurethane models of proximal and distal end-to-side anastomoses of angles 15, 30, 45, 60 and 80 degrees using pulsati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00056-1

    authors: Gaupp S,Wang Y,How TV,Fish PJ

    更新日期:1999-07-01 00:00:00

  • Effect of simulated joint instability and bracing on ankle and subtalar joint flexibility.

    abstract::It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.033

    authors: Choisne J,McNally A,Hoch MC,Ringleb SI

    更新日期:2019-01-03 00:00:00

  • Numerical exploration of the combined effect of nutrient supply, tissue condition and deformation in the intervertebral disc.

    abstract::Novel strategies to heal discogenic low back pain could highly benefit from comprehensive biophysical studies that consider both mechanical and biological factors involved in intervertebral disc degeneration. A decrease in nutrient availability at the bone-disc interface has been indicated as a relevant risk factor an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.004

    authors: Malandrino A,Noailly J,Lacroix D

    更新日期:2014-04-11 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • The behavior of adaptive bone-remodeling simulation models.

    abstract::The process of adaptive bone remodeling can be described mathematically and simulated in a computer model, integrated with the finite element method. In the model discussed here, cortical and trabecular bone are described as continuous materials with variable density. The remodeling rule applied to simulate the remode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90056-7

    authors: Weinans H,Huiskes R,Grootenboer HJ

    更新日期:1992-12-01 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Twenty-fold difference in hemodynamic wall shear stress between murine and human aortas.

    abstract::Endothelial cells regulate vascular tone and mural remodelling in a shear-dependent manner that is commonly assumed to keep wall shear stress constant across arteries and species. Allometric arguments show that aortic flow velocity is constant across species, a deduction that is consistent with much experimental data,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.020

    authors: Weinberg PD,Ross Ethier C

    更新日期:2007-01-01 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure.

    abstract::Accidentology data showed that liver is often injured in car crashes; three types of injuries occur: hematoma, laceration and vessel failure. This paper focuses on surface laceration, which involves liver capsule and hepatic parenchyma. Liver capsule behavior has been studied but its failure properties are still uncle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.038

    authors: Brunon A,Bruyère-Garnier K,Coret M

    更新日期:2010-08-10 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • In vivo estimation of the glenohumeral joint centre by functional methods: accuracy and repeatability assessment.

    abstract::Several algorithms have been proposed for determining the centre of rotation of ball joints. These algorithms are used rather to locate the hip joint centre. Few studies have focused on the determination of the glenohumeral joint centre. However, no studies have assessed the accuracy and repeatability of functional me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.029

    authors: Lempereur M,Leboeuf F,Brochard S,Rousset J,Burdin V,Rémy-Néris O

    更新日期:2010-01-19 00:00:00

  • Study of cradle and pendulum motion for applications to health care.

    abstract::Hammocks and cradles have long been appreciated, but in a very limited way. Aside from being emotionally soothing the devices affect the skin and all deep body components. While structurally simple they are functionally quite sophisticated and could very well affect the pattern of health care across the board--acute, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90089-7

    authors: Frisina W

    更新日期:1984-01-01 00:00:00

  • Pain catastrophizing moderates changes in spinal control in response to noxiously induced low back pain.

    abstract::It is generally accepted that spine control and stability are relevant for the prevention and rehabilitation of low back pain (LBP). However, there are conflicting results in the literature in regards to how these variables are modified in the presence of LBP. The aims of the present work were twofold: (1) to use noxi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.010

    authors: Ross GB,Sheahan PJ,Mahoney B,Gurd BJ,Hodges PW,Graham RB

    更新日期:2017-06-14 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • Random field assessment of inhomogeneous bone mineral density from DXA scans can enhance the differentiation between postmenopausal women with and without hip fractures.

    abstract::Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogene...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.030

    authors: Dong XN,Pinninti R,Lowe T,Cussen P,Ballard JE,Di Paolo D,Shirvaikar M

    更新日期:2015-04-13 00:00:00

  • Theoretical justification for distal foot power equation.

    abstract::The distal foot power equation is a simple yet powerful tool for estimating the power dissipation or generation within the foot even while modeling it as a rigid body. It was introduced over two decades ago, but has seen a resurgence of use in recent years. Nevertheless, the theoretical justification for this formula ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109964

    authors: Ashby BM

    更新日期:2020-08-26 00:00:00

  • The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

    abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.036

    authors: Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ