Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

Abstract:

:Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips of R=5, 25, 65, and 200 μm. Nanoindentation arrays, not targeted to fall on specific structures or locations, enabled statistical sampling of osteons within PMMA-embedded, bovine, cortical bone on a single sample to a range of maximum displacements (minimum of 100 nm and maximum of 2000 nm). Elastic finite element models were then utilized to isolate the contributions of indenter tip radius, contact area, and position within the lamellar structure in comparison to the experimental results. For a small, R=5 μm indenter tip, indentation modulus consistently increased with contact depth and increased plastic deformation, resulting in an artificial increase in elastic properties. While larger radius tips (R=25, 65, and 200 μm) did not enable evaluation of a high spatial resolution on the surface, they produced data that was representative of the lower load and contact depth measurements with the smaller tip. However the sensitivity to mechanical property variations across the 2-D surface of the material was lost with increase in indenter tip size. Correspondingly, measurement variance was also decreased as the volume contributing to the indent response represented an average of surface roughness, varying mineral content, defects, and underlying tissue type and structure.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Paietta RC,Campbell SE,Ferguson VL

doi

10.1016/j.jbiomech.2010.10.008

subject

Has Abstract

pub_date

2011-01-11 00:00:00

pages

285-90

issue

2

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(10)00560-9

journal_volume

44

pub_type

杂志文章
  • Changes in stationary upright standing and proprioceptive reflex control of foot muscles after fatiguing static foot inversion.

    abstract::We searched for the consequences of a maximal static foot inversion sustained until exhaustion on the post-exercise stationary upright standing and the proprioceptive control of the foot muscles. Twelve healthy subjects executed an unilateral maximal static foot inversion during which continuous power spectrum analyse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.005

    authors: Vie B,Gomez N,Brerro-Saby C,Weber JP,Jammes Y

    更新日期:2013-06-21 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Theoretical justification for distal foot power equation.

    abstract::The distal foot power equation is a simple yet powerful tool for estimating the power dissipation or generation within the foot even while modeling it as a rigid body. It was introduced over two decades ago, but has seen a resurgence of use in recent years. Nevertheless, the theoretical justification for this formula ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109964

    authors: Ashby BM

    更新日期:2020-08-26 00:00:00

  • In vivo porcine left atrial wall stress: Effect of ventricular tachypacing on spatial and temporal stress distribution.

    abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.003

    authors: Di Martino ES,Bellini C,Schwartzman DS

    更新日期:2011-11-10 00:00:00

  • Glenohumeral joint cartilage contact in the healthy adult during scapular plane elevation depression with external humeral rotation.

    abstract::The shoulder (glenohumeral) joint has the greatest range of motion of all human joints; as a result, it is particularly vulnerable to dislocation and injury. The ability to non-invasively quantify in-vivo articular cartilage contact patterns of joints has been and remains a difficult biomechanics problem. As a result,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.034

    authors: Massimini DF,Warner JJ,Li G

    更新日期:2014-09-22 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Growth and surface folding of esophageal mucosa: a biomechanical model.

    abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.007

    authors: Li B,Cao YP,Feng XQ

    更新日期:2011-01-04 00:00:00

  • Vocal fold contact patterns based on normal modes of vibration.

    abstract::The fluid-structure interaction and energy transfer from respiratory airflow to self-sustained vocal fold oscillation continues to be a topic of interest in vocal fold research. Vocal fold vibration is driven by pressures on the vocal fold surface, which are determined by the shape of the glottis and the contact betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.011

    authors: Smith SL,Titze IR

    更新日期:2018-05-17 00:00:00

  • Establishing reference values for cervical spine range of motion in pre-pubescent children.

    abstract::Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.021

    authors: Lynch-Caris T,Majeske KD,Brelin-Fornari J,Nashi S

    更新日期:2008-08-28 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Computer simulation of blood flow in the human arm.

    abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90019-5

    authors: Balar SD,Rogge TR,Young DF

    更新日期:1989-01-01 00:00:00

  • Microdamage evaluation in human trabecular bone based on nonlinear ultrasound vibro-modulation (NUVM).

    abstract::The primary aim of this work is to investigate the potential of nonlinear ultrasound for microdamage detection in human bone. Microdamage evaluation in human bone is of great importance, because it is considered a significant parameter for characterizing fracture risk. Experiments employing nonlinear acoustic vibro-mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.12.018

    authors: Zacharias K,Balabanidou E,Hatzokos I,Rekanos IT,Trochidis A

    更新日期:2009-03-26 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • Model of muscle-tendon interaction during frog semitendinosis fixed-end contractions.

    abstract::A structural model was developed to explain sarcomere shortening at the expense of tendon lengthening in the frog semitendinosis (ST) muscle-tendon system. The model was based on the data of Lieber et al. [Am. J. Physiol. 261, C86-C92 (1991)], who determined the relationship between the sarcomere length, tendon load (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90261-x

    authors: Lieber RL,Brown CG,Trestik CL

    更新日期:1992-04-01 00:00:00

  • Mechanical and material properties of the plantarflexor muscles and Achilles tendon in children with spastic cerebral palsy and typically developing children.

    abstract:BACKGROUND:Children with spastic cerebral palsy (CP) experience secondary musculoskeletal adaptations, affecting the mechanical and material properties of muscles and tendons. CP-related changes in the spastic muscle are well documented whilst less is known about the tendon. From a clinical perspective, it is important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.020

    authors: Theis N,Mohagheghi AA,Korff T

    更新日期:2016-09-06 00:00:00

  • Mathematical model of the human ankle joint.

    abstract::It has been suspected that the mechanical environment in which a particular joint functions has an effect on the initiation or progression of degenerative joint disease. The objective of this study is to define the mechanical environment of the ankle joint, specifically, the contact areas and pressure distributions, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90132-x

    authors: Wynarsky GT,Greenwald AS

    更新日期:1983-01-01 00:00:00

  • Lumbar spinal muscle activation synergies predicted by multi-criteria cost function.

    abstract::The hypothesis that control of lumbar spinal muscle synergies is biomechanically optimized was studied by comparing EMG data with an analytical model with a multi-component cost function that could include (1) trunk displacements, (2) intervertebral displacements, (3) intervertebral forces; (4) sum of cubed muscle str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00034-3

    authors: Stokes IA,Gardner-Morse M

    更新日期:2001-06-01 00:00:00

  • A finite viscoelastic-plastic model for describing the uniaxial ratchetting of soft biological tissues.

    abstract::In this paper, a phenomenological constitutive model is constructed to describe the uniaxial ratchetting (i.e., the cyclic accumulation of inelastic deformation) of soft biological tissues in the framework of finite viscoelastic-plasticity. The model is derived from a polyconvex elastic free energy function and addres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.004

    authors: Zhu Y,Kang G,Kan Q,Yu C

    更新日期:2014-03-21 00:00:00

  • Fluid load support during localized indentation of cartilage with a spherical probe.

    abstract::Interstitial fluid pressurization, a consequence of a biphasic tissue structure, is essential to the load bearing and lubrication properties of articular cartilage. Focal tissue degradation may interfere with this protective mechanism, eventually leading to gross degeneration and osteoarthritis. Our long-term goal is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.12.019

    authors: Bonnevie ED,Baro VJ,Wang L,Burris DL

    更新日期:2012-04-05 00:00:00

  • Femoral neck bone adaptation to weight-bearing physical activity by computational analysis.

    abstract::Individual differences in bone mass distribution at the proximal femur may be determined by daily weight-bearing physical activity (PA) since bone self-adapts according to the mechanical loads that is submitted. The aim of this study was to analyse computationally the effect of different weight-bearing PA types in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.031

    authors: Machado MM,Fernandes PR,Cardadeiro G,Baptista F

    更新日期:2013-09-03 00:00:00

  • An experimental setup for the measurement of forces on a human cadaveric foot during inversion.

    abstract::An experimental setup was developed for statically measuring seven vertical and three horizontal reaction forces on the foot. In the setup, the leg can be simultaneously loaded (1) by a vertical force, (2) by an externally applied axial moment, and (3) by simulated muscle forces. The foot is free to invert under influ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90080-8

    authors: Ottevanger EJ,Spoor CW,van Leeuwen JL,Sauren AA,Janssen JD,Huson A

    更新日期:1989-01-01 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00

  • The mechanical effects of different levels of cement penetration at the cement-bone interface.

    abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.033

    authors: Waanders D,Janssen D,Mann KA,Verdonschot N

    更新日期:2010-04-19 00:00:00

  • Versatile and inexpensive Hall-Effect force sensor for mechanical characterization of soft biological materials.

    abstract::Mismatch of hierarchical structure and mechanical properties between tissue-engineered implants and native tissue may result in signal cues that negatively impact repair and remodeling. With bottom-up tissue engineering approaches, designing tissue components with proper microscale mechanical properties is crucial to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.065

    authors: Backman DE,LeSavage BL,Wong JY

    更新日期:2017-01-25 00:00:00

  • Mechanical properties vary for different regions of the finger extensor apparatus.

    abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.035

    authors: Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

    更新日期:2014-09-22 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • The effect of isolated valgus moments on ACL strain during single-leg landing: a simulation study.

    abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.031

    authors: Shin CS,Chaudhari AM,Andriacchi TP

    更新日期:2009-02-09 00:00:00