Mechanical properties vary for different regions of the finger extensor apparatus.

Abstract:

:The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the force distribution within the extensor apparatus, or hood, and the transmission to the phalanges is challenging, especially as knowledge of the underlying mechanical properties of the tissue is limited. We undertook quantification of some of these properties through material testing of cadaver specimens. We punched samples at specified locations from 19 extensor hood specimens. Material testing was performed to failure for each sample with a custom material testing device. Testing revealed significant differences in ultimate load, ultimate strain, thickness, and tangent modulus along the length of the extensor hood. Specifically, thickness, ultimate load, and ultimate strain were greater in the more proximal sections of the extensor hood, while the tangent modulus was greater in the more distal sections. The variations in mechanical properties within the hood may impact prediction of force transmission and, thus, should be considered when modeling the action of the extensor apparatus. Across the extensor hood, tangent modulus values were substantially smaller than values reported for other soft tissues, such as the Achilles tendon and knee ligaments, while ultimate strains were much greater. Thus, the tissue in the extensor apparatus seems to have greater elasticity, which should be modeled accordingly.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

doi

10.1016/j.jbiomech.2014.06.035

subject

Has Abstract

pub_date

2014-09-22 00:00:00

pages

3094-9

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00374-1

journal_volume

47

pub_type

杂志文章
  • High-acceleration whole body vibration stimulates cortical bone accrual and increases bone mineral content in growing mice.

    abstract::Whole body vibration (WBV) is a promising tool for counteracting bone loss. Most WBV studies on animals have been performed at acceleration <1g and frequency between 30 and 90Hz. Such WBV conditions trigger bone growth in osteopenia models, but not in healthy animals. In order to test the ability of WBV to promote ost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.031

    authors: Gnyubkin V,Guignandon A,Laroche N,Vanden-Bossche A,Malaval L,Vico L

    更新日期:2016-06-14 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Efficiency as a predictor of human jaw design in the sagittal plane.

    abstract::The effects of changing the direction of the bite force and of the mandibular joint reaction have been studied with a mathematical model assisted by a computer using the technique of linear programming. We conclude the following: In the sagittal plane the long axes of lower molars are each tilted in the direction that...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90246-6

    authors: Baragar FA,Osborn JW

    更新日期:1987-01-01 00:00:00

  • Predictive equations to estimate spinal loads in symmetric lifting tasks.

    abstract::Response surface methodology is used to establish robust and user-friendly predictive equations that relate responses of a complex detailed trunk finite element biomechanical model to its input variables during sagittal symmetric static lifting activities. Four input variables (thorax flexion angle, lumbar/pelvis rati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.028

    authors: Arjmand N,Plamondon A,Shirazi-Adl A,Larivière C,Parnianpour M

    更新日期:2011-01-04 00:00:00

  • T2 relaxation time measurements in tibiotalar cartilage after barefoot running and its relationship to ankle biomechanics.

    abstract::The influence of ankle kinematics and plantar pressure from mid-range barefoot running on T2 relaxation times of tibiotalar cartilage is unknown. This study aimed to quantitatively evaluate the T2 relaxation time of tibiotalar cartilage and ankle biomechanics following 5 km barefoot running. Twenty healthy runners (wh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.046

    authors: Kyung Kim H,Fernandez J,Logan C,Tarr GP,Doyle A,Mirjalili SA

    更新日期:2019-06-11 00:00:00

  • An analytical study on the thermal effects of cryosurgery on selective cell destruction.

    abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.005

    authors: Chua KJ,Chou SK,Ho JC

    更新日期:2007-01-01 00:00:00

  • Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    abstract::Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and int...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.028

    authors: Boser QA,Valevicius AM,Lavoie EB,Chapman CS,Pilarski PM,Hebert JS,Vette AH

    更新日期:2018-04-27 00:00:00

  • Measurement of whole-body vibration by double-pulsed holography.

    abstract::A technique for registering vibration and deformation patterns has been adapted for the measurement of whole-body vibration in humans. Double-exposure holographic interferometry produces three dimensional pictures of the body, allowing exact measurement of the subject's movement between the two pulses. In this study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90036-8

    authors: Wangenheim M,Holzmann P,Svensson LB

    更新日期:1984-01-01 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00

  • A physical model for simulating fusion of impaction-grafted morselized cancellous bone.

    abstract::This article describes a method to simulate fusion of morselized cancellous bone. The morselized cancellous bone is mixed with an epoxy adhesive, in empirically determined proportions. The mixture is then impacted into a construct. When the epoxy cures, the morselized material fuses into a cohesive, contiguous structu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00032-x

    authors: Heiner AD,Brown TD

    更新日期:2001-06-01 00:00:00

  • A mechanistic model for internal bone remodeling exhibits different dynamic responses in disuse and overload.

    abstract::Bone is a dynamic tissue which, through the process of bone remodeling in the mature skeleton, renews itself during normal function and adapts to mechanical loads. It is, therefore, important to understand the effect of remodeling on the mechanical function of bone, as well as the effect of the inherent time lag in th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00221-9

    authors: Hazelwood SJ,Bruce Martin R,Rashid MM,Rodrigo JJ

    更新日期:2001-03-01 00:00:00

  • Altered frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during downhill gait in patients with mixed knee osteoarthritis.

    abstract::Patients with knee osteoarthritis often present with signs of mixed tibiofemoral and patellofemoral joint disease. It has been suggested that altered frontal and transverse plane knee joint mechanics play a key role in compartment-specific patterns of knee osteoarthritis, but in-vivo evidence in support of this premis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.015

    authors: Farrokhi S,Meholic B,Chuang WN,Gustafson JA,Fitzgerald GK,Tashman S

    更新日期:2015-07-16 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • The influence of the instabilities in modelling arteriovenous junction haemodynamics.

    abstract::The arteriovenous junction is characterised by high flow rates, large pressure difference and typically a palpable thrill or audible bruit, associated with turbulent flow. However, the arteriovenous junction is frequently studied with the assumption of streamline flow. This assumption is based on the Reynolds number c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.038

    authors: Broderick SP,Houston JG,Walsh MT

    更新日期:2015-10-15 00:00:00

  • Biomechanical effect of rapid mucoperiosteal palatal tissue expansion with the use of osmotic expanders.

    abstract::The comparative study was performed to investigate the biomechanical properties (maximum tangential stiffness, maximum tangential modulus and tensile strength) of expanded mucoperiosteal palatal tissue after rapid expansion regimen correlated with histological findings. Rabbit palatal model was used to correlate the n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.012

    authors: Wysocki M,Kobus K,Szotek S,Kobielarz M,Kuropka P,Będziński R

    更新日期:2011-04-29 00:00:00

  • Comparison of the vulnerability risk for positive versus negative atheroma plaque morphology.

    abstract::As plaque develops in arteries two types of remodeling can occur; positive and negative remodeling. Positive remodeling is an outward compensatory remodeling in which the arterial wall grows outward in an attempt to maintain a constant lumen diameter, while negative remodeling is defined as a local shrinkage of vessel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.02.012

    authors: Cilla M,Peña E,Martínez MA,Kelly DJ

    更新日期:2013-04-26 00:00:00

  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00

  • Effect of material damping on bone remodelling.

    abstract::This paper considers the effect of internal material damping on the stresses, strains, and surface and internal remodelling behaviour in a section of axisymmetrical bone with a force-fitted axially oriented medullary pin. The bone response to several loading situations is modelled using visco-elastic equations. An app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90291-0

    authors: Misra JC,Samanta S

    更新日期:1987-01-01 00:00:00

  • Comparison of models for flow induced deformation of soft biological tissue.

    abstract::The behaviour of a deformable porous medium during the flow of fluid under a pressure difference is examined for both infinitesimal and finite deformations. Models for both cases are solved for the problem of steady one-dimensional compression and compared with experimental data from Parker et al. (J. appl. Mech. 54, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90164-x

    authors: Barry SI,Aldis GK

    更新日期:1990-01-01 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials.

    abstract::Plastic deformation of sutures creates an irreversible extension during load. To test our hypothesis that such plastic deformation causes gap formation after tendon repair, we determined the plasticity of five different suture materials commonly used in tendon surgery. Prolene, Polydioxanone (PDS), Ethibond, Vicryl, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.023

    authors: Jordan MC,Boelch S,Jansen H,Meffert RH,Hoelscher-Doht S

    更新日期:2016-09-06 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodelling.

    abstract::The skeleton consists of a series of elements with a variety of functions. In locations where shape or protection are of prime importance the bone's architecture is achieved during growth under direct genetic control. In locations where resistance to repetitive loading is important only the general form of the bone wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(87)90026-1

    authors: Lanyon LE

    更新日期:1987-01-01 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Mechanical interaction of center of pressure and force direction in the upright human.

    abstract::Humans maintain upright bipedal posture by producing appropriate force against the environment through the interaction of neural controlled muscle force with the mechanics of the skeletal system. Characterizing these mechanics facilitates understanding of the neural control. We used a mechanical model of an upright hu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.018

    authors: Gruben KG,Boehm WL

    更新日期:2012-06-01 00:00:00

  • Loading and deformation of the cat posterior knee joint capsule in axial and extension rotations.

    abstract::Deformation and loading of the knee posterior joint capsule were studied in the cat, in extension rotations and in axial external (ER) and internal (IR) rotations at full extension. Loads were measured in the ligament along the upper edge of the capsule, using mechanically sensitive neurons that were calibrated as loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90352-f

    authors: Grigg P,Hoffman AH

    更新日期:1993-11-01 00:00:00