Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials.

Abstract:

:Plastic deformation of sutures creates an irreversible extension during load. To test our hypothesis that such plastic deformation causes gap formation after tendon repair, we determined the plasticity of five different suture materials commonly used in tendon surgery. Prolene, Polydioxanone (PDS), Ethibond, Vicryl, and FiberWire sutures were biomechanically tested to determine their offset yield strength, initial extension, creep, relaxed elongation, peak-to-peak displacement, stiffness, and maximum tensile strength under static, constant, and cyclic loading. In addition, 35 porcine hindlimb tendons were used to evaluate gap formation and the biomechanical behavior of the suture materials after tendon repair. Prolene had a low offset yield strength and high initial extensions at 30, 60, and 90N combined with relatively large creep, relaxed elongation, and peak-to-peak displacement. Aside from the low maximum tensile strength and stiffness, these parameters indicate an early plastic deformation during loading. The material properties of PDS were generally better for suturing than those of Prolene, but no difference was found in offset yield strength or initial extension. In contrast to the monofilament materials Prolene and PDS, the braided Ethibond, Vicryl, and FiberWire materials showed significantly less plastic deformation. The lowest amount of plastic deformation was found in the FiberWire and the results for Ethibond and Vicryl were equal. Gap formation occurred at the lowest tension force in the Prolene group, but only FiberWire required a significantly larger tension force to produce gapping at the repair site, indicating a higher resistance to gap formation. The results of this study show that plastic deformation occurs at a lower tension force in the monofilament sutures Prolene and PDS than in the braided materials Ethibond, Vicryl, and FiberWire. After tendon repair, FiberWire likely prevents gap formation, whereas Prolene induces gapping through low-tension plastic deformation. Therefore, plastic deformation should be considered when selecting suture materials for tendon repair surgery.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Jordan MC,Boelch S,Jansen H,Meffert RH,Hoelscher-Doht S

doi

10.1016/j.jbiomech.2016.05.023

subject

Has Abstract

pub_date

2016-09-06 00:00:00

pages

2607-2612

issue

13

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)30606-6

journal_volume

49

pub_type

杂志文章
  • Passive stress-strain relation for the right ventricle in diastole.

    abstract::Wall thickness and medial line radii of an in vitro canine heart are measured. These data are assumed to be characteristic of the in vivo ventricles subject to zero pressure, and in the absence of filling. The myocardium is taken to be homogeneous, isotropic, non-linearly elastic, and incompressible. The right ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90171-3

    authors: Moskowitz SE

    更新日期:1982-01-01 00:00:00

  • The damping properties of the venous plexus of the heel region of the foot during simulated heelstrike.

    abstract::The damping mechanisms that are operational in the heel pad during the impact phase of locomotion have the important function to protect the musculo-skeletal system from injuries. How this is achieved is still not fully understood, as is for instance illustrated by the 'heel pad paradox', the observation that in vivo ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.10.006

    authors: Weijers RE,Kessels AG,Kemerink GJ

    更新日期:2005-12-01 00:00:00

  • Control of trunk motion following sudden stop perturbations during cart pushing.

    abstract::External perturbations during pushing tasks have been suggested to be a risk factor for low-back symptoms. An experiment was designed to investigate whether self-induced and externally induced sudden stops while pushing a high inertia cart influence trunk motions, and how flexor and extensor muscles counteract these p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.036

    authors: Lee YJ,Hoozemans MJ,van Dieën JH

    更新日期:2011-01-04 00:00:00

  • An ocular biomechanic model for dynamic simulation of different eye movements.

    abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.006

    authors: Iskander J,Hossny M,Nahavandi S,Del Porto L

    更新日期:2018-04-11 00:00:00

  • Comparison of shear forces and ligament loading in the healthy and ACL-deficient knee during gait.

    abstract::The purpose of this study was to predict and explain the pattern of shear force and ligament loading in the ACL-deficient knee during walking, and to compare these results to similar calculations for the healthy knee. Musculoskeletal modeling and computer simulation were combined to calculate ligament forces in the AC...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.07.001

    authors: Shelburne KB,Pandy MG,Torry MR

    更新日期:2004-03-01 00:00:00

  • Random field assessment of inhomogeneous bone mineral density from DXA scans can enhance the differentiation between postmenopausal women with and without hip fractures.

    abstract::Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogene...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.030

    authors: Dong XN,Pinninti R,Lowe T,Cussen P,Ballard JE,Di Paolo D,Shirvaikar M

    更新日期:2015-04-13 00:00:00

  • Micropipette aspiration method for characterizing biological materials with surface energy.

    abstract::Many soft biological tissues possess a considerable surface stress, which plays a significant role in their biophysical functions, but most previous methods for characterizing their mechanical properties have neglected the effects of surface stress. In this work, we investigate the micropipette aspiration method to me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.020

    authors: Ding Y,Wang GF,Feng XQ,Yu SW

    更新日期:2018-10-26 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Theoretical study of intracellular stress fiber orientation under cyclic deformation.

    abstract::We studied stress fiber orientation under a wide range of uniaxial cyclic deformations. We devised and validated a hypothesis consisting of two parts, as follows: (1) a stress fiber aligns to avoid a mechanical stimulus in the fiber direction under cyclic deformation. This means that, among all allowable directions, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00114-7

    authors: Yamada H,Takemasa T,Yamaguchi T

    更新日期:2000-11-01 00:00:00

  • A physiological approach to the simulation of bone remodeling as a self-organizational control process.

    abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90049-3

    authors: Mullender MG,Huiskes R,Weinans H

    更新日期:1994-11-01 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • An analysis of the squeeze-film lubrication mechanism for articular cartilage.

    abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90024-u

    authors: Hou JS,Mow VC,Lai WM,Holmes MH

    更新日期:1992-03-01 00:00:00

  • Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison.

    abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.035

    authors: Gijsbertse K,Sprengers A,Naghibi Beidokhti H,Nillesen M,de Korte C,Verdonschot N

    更新日期:2018-05-17 00:00:00

  • A numerical method for simulating the dynamics of human walking.

    abstract::This paper presents a general method for simulating the movement of the lower extremity during human walking. It is based upon two separate algorithms: one for single support (an open kinematic chain), and the other for the double support phase (a closed-loop linkage). Central to each of these is the recursive Newton-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90250-3

    authors: Pandy MG,Berme N

    更新日期:1988-01-01 00:00:00

  • Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon.

    abstract::To test the hypothesis that stress deprivation induces over-expression of cytokines in the patellar tendon, 40 rats were divided into the following two groups. In the stress-shielded group, we slackened the patellar tendon in the right knee by drawing the patella toward the tibial tubercle with flexible wires. In the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.009

    authors: Uchida H,Tohyama H,Nagashima K,Ohba Y,Matsumoto H,Toyama Y,Yasuda K

    更新日期:2005-04-01 00:00:00

  • The influence of center-of-mass movements on the variation in the structure of human postural sway.

    abstract::The present article investigates the influence of center-of-mass movements on the variation of the structure in human postural sway. Twelve healthy younger persons performed 60s quiet standing, 60s relaxed standing, and 10 min relaxed standing on two force plates. Center-of-pressure (CoP) and gravitational line (GL) p...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.016

    authors: Ihlen EA,Skjæret N,Vereijken B

    更新日期:2013-02-01 00:00:00

  • Hydro-resistive measurement of dynamic lifting strength.

    abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00155-8

    authors: Pinder AD,Grieve DW

    更新日期:1997-04-01 00:00:00

  • Thigh-calf contact parameters for six high knee flexion postures: Onset, maximum angle, total force, contact area, and center of force.

    abstract::In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.022

    authors: Kingston DC,Acker SM

    更新日期:2018-01-23 00:00:00

  • Steady flow in a model of the human carotid bifurcation. Part I--flow visualization.

    abstract::The geometry of a typical adult human carotid bifurcation, complete with the sinus, was established from a study of a large number of angiograms. A rigid model was constructed from glass and investigations were performed under steady flow conditions using flow visualization techniques over a range of upstream Reynolds...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90057-4

    authors: Bharadvaj BK,Mabon RF,Giddens DP

    更新日期:1982-01-01 00:00:00

  • Formation and travel of vortices in model ventricles: application to the design of skeletal muscle ventricles.

    abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00065-8

    authors: Shortland AP,Black RA,Jarvis JC,Henry FS,Iudicello F,Collins MW,Salmons S

    更新日期:1996-04-01 00:00:00

  • Humans control stride-to-stride stepping movements differently for walking and running, independent of speed.

    abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.034

    authors: Dingwell JB,Bohnsack-McLagan NK,Cusumano JP

    更新日期:2018-07-25 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion.

    abstract::Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.018

    authors: Kureshi A,Vaiude P,Nazhat SN,Petrie A,Brown RA

    更新日期:2008-12-05 00:00:00

  • The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

    abstract::Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.021

    authors: Defrate LE,van der Ven A,Boyer PJ,Gill TJ,Li G

    更新日期:2006-01-01 00:00:00

  • Modification of spastic gait through mechanical damping.

    abstract::The effect of dissipative mechanical loads on spastic gait has been studied, to evaluate the feasibility of using mechanically damped orthoses to effect functional improvements in the gait of spastic patients. This concept is based on a hypothesis citing uninhibited, velocity-dependent stretch reflexes as a possible c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90278-7

    authors: Maki BE,Rosen MJ,Simon SR

    更新日期:1985-01-01 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • Robotic simulation of identical athletic-task kinematics on cadaveric limbs exhibits a lack of differences in knee mechanics between contralateral pairs.

    abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.019

    authors: Bates NA,McPherson AL,Nesbitt RJ,Shearn JT,Myer GD,Hewett TE

    更新日期:2017-02-28 00:00:00

  • A force plate study of avian gait.

    abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.014

    authors: Corr SA,McCorquodale C,McDonald J,Gentle M,McGovern R

    更新日期:2007-01-01 00:00:00

  • Validation of a novel method for quantifying and comparing regional ACL elongations during uniaxial tensile loading.

    abstract::Given the complex three-dimensional (3D) knee joint loading associated with anterior cruciate ligament (ACL) injuries, accurate site- and bundle-specific strain measurements are critical. The purpose of this study was to quantify tensile load-induced migrations of radio-opaque markers injected directly into the ACL, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.016

    authors: Beaulieu ML,Haladik JA,Bey MJ,McLean SG

    更新日期:2012-10-11 00:00:00

  • A puzzle assembly strategy for fabrication of large engineered cartilage tissue constructs.

    abstract::Engineering of large articular cartilage tissue constructs remains a challenge as tissue growth is limited by nutrient diffusion. Here, a novel strategy is investigated, generating large constructs through the assembly of individually cultured, interlocking, smaller puzzle-shaped subunits. These constructs can be engi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.023

    authors: Nover AB,Jones BK,Yu WT,Donovan DS,Podolnick JD,Cook JL,Ateshian GA,Hung CT

    更新日期:2016-03-21 00:00:00