Abstract:
:Response surface methodology is used to establish robust and user-friendly predictive equations that relate responses of a complex detailed trunk finite element biomechanical model to its input variables during sagittal symmetric static lifting activities. Four input variables (thorax flexion angle, lumbar/pelvis ratio, load magnitude, and load position) and four model responses (L4-L5 and L5-S1 disc compression and anterior-posterior shear forces) are considered. Full factorial design of experiments accounting for all combinations of input levels is employed. Quadratic predictive equations for the spinal loads at the L4-S1 disc mid-heights are obtained by regression analysis with adequate goodness-of-fit (R(2)>98%, p<0.05, and low root-mean-squared-error values compared with the range of predicted spine loads). Results indicate that intradiscal pressure values at the L4-L5 disc estimated based on the predictive equations are in close agreement with available in vivo data measured under similar loadings and postures. Combinations of input (posture and loading) variable levels that yield spine loads beyond the tolerance compression limit of 3400 N are identified using contour plots. Ergonomists and bioengineers, faced with the dilemma of using either complex but more accurate models on one hand or less accurate but simple models on the other hand, have thereby easy-to-use predictive equations that quantifies spinal loads and risk of injury under different occupational tasks of interest.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Arjmand N,Plamondon A,Shirazi-Adl A,Larivière C,Parnianpour Mdoi
10.1016/j.jbiomech.2010.08.028subject
Has Abstractpub_date
2011-01-04 00:00:00pages
84-91issue
1eissn
0021-9290issn
1873-2380pii
S0021-9290(10)00472-0journal_volume
44pub_type
杂志文章abstract::Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dyna...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.024
更新日期:2012-01-03 00:00:00
abstract::Cellular mechanotransduction is an integral part of many crucial physiological processes, but non-invasive tools for quantifying intracellular strain in vivo are not available for complex tissues such as bone. As a first step to address this gap, we have utilized a novel, non-invasive approach to quantify cellular str...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.08.023
更新日期:2016-10-03 00:00:00
abstract::The understanding of impact mechanics during locomotion is important for research within the fields of injury prevention and footwear design. Instrumented missiles offer a worthy solution to the lack of control inherent in in vivo activities and to the isolated nature of tissue studies. However, missiles cannot mimic ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00002-y
更新日期:1995-09-01 00:00:00
abstract::Epigenetics is the regulation of gene expression (transcription) in response to changes in the cell environment through genomic modifications that largely involve the non-coding fraction of the human genome and that cannot be attributed to modification of the primary DNA sequence. Epigenetics is dominant in establishi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.017
更新日期:2017-01-04 00:00:00
abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.033
更新日期:2010-04-19 00:00:00
abstract::The reference point indentation (RPI) method is a microindentation technique involving successive indentation cycles. We employed RPI to measure average stiffness (Ave US), indentation distance increase (IDI), total indentation distance (TID), average energy dissipated (Ave ED), and creep indentation distance (CID) of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.04.003
更新日期:2013-06-21 00:00:00
abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.03.002
更新日期:2019-05-09 00:00:00
abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.045
更新日期:2012-02-02 00:00:00
abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.02.002
更新日期:2007-01-01 00:00:00
abstract::We present a generalized beam theory in which deformation and load are determined simultaneously, in order to analyze statically indeterminant problems involving long bones. We regard a long bone as a beam curved in three dimensions for which the cross-sectional properties vary continuously along its length. The theor...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90087-0
更新日期:1989-01-01 00:00:00
abstract::In this study, bulge inflation tests were used to characterize the failure response of 15 layers of human ascending thoracic aortic aneurysms (ATAA). Full field displacement data were collected during each of the mechanical tests using a digital image stereo-correlation (DIS-C) system. Using the collected displacement...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.12.012
更新日期:2014-02-07 00:00:00
abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.049
更新日期:2019-02-14 00:00:00
abstract::This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90331-g
更新日期:1991-01-01 00:00:00
abstract::The purpose of this investigation was to determine the feasibility of using a single inertial measurement unit (IMU) placed on the sacrum to estimate 3-dimensional ground reaction force (F) during linear acceleration and change of direction tasks. Force plate measurements of F and estimates from the proposed IMU metho...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.07.035
更新日期:2017-08-16 00:00:00
abstract::Groups of rats were killed at 2, 6, 12, and 24 months of age. From dissected left and right mandibles in each rat, three pairs of transverse sections were cut at the incisal, middle, and basal regions of the incisor. One section in each pair was loaded until failure and a stress-strain curve for the periodontal ligame...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.11.013
更新日期:2004-07-01 00:00:00
abstract::Structural properties of articular cartilage such as proteoglycan content, collagen content and collagen alignment are known to vary over length scales as small as a few microns (Bullough and Goodfellow, 1968; Bi et al., 2006). Characterizing the resulting variation in mechanical properties is critical for understandi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.012
更新日期:2010-03-03 00:00:00
abstract::Evaluation of workers' body posture in workstations is a prerequisite to estimate spinal loads and assess risk of injury for the subsequent design of preventive interventions. The Microsoft Kinect™ sensor is, in this regard, advantageous over the traditional skin-marker-based optical motion capture systems for being m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110043
更新日期:2020-11-09 00:00:00
abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.08.006
更新日期:2017-10-03 00:00:00
abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00081-e
更新日期:1995-04-01 00:00:00
abstract::The remodeling of fibroblast-seeded collagen gels in response to dynamic mechanical stimuli was investigated by using a newly developed biaxial culture system capable of cyclically stretching planar soft tissues. Fibroblast-seeded collagen gels were subjected to three distinct dynamic mechanical conditions for six day...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.030
更新日期:2018-09-10 00:00:00
abstract::Heart valves induce flow disturbances which play a role in blood cell activation and damage, but questions of the magnitude and spatial distribution of fluid stresses (wall shear stress and turbulent stress) cannot be readily addressed with current experimental techniques. Therefore, a numerical simulation procedure f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90015-9
更新日期:1994-04-01 00:00:00
abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.016
更新日期:2017-10-03 00:00:00
abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00055-4
更新日期:1998-07-01 00:00:00
abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00202-x
更新日期:2000-04-01 00:00:00
abstract::This paper deals with the impact force during foot-ground impact activities such as the running. A previously developed model is used for this study. The model is a lumped-parameter one consisting of four masses connected to each other via linear springs and viscous dampers. A shoe-specific nonlinear function is used ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.09.016
更新日期:2007-01-01 00:00:00
abstract::Deep tissue injury (DTI) is a severe kind of pressure ulcers formed by sustained deformation of muscle tissues over bony prominences. As a major clinical issue, DTI affects people with physical disabilities, and is obviously related to the load-bearing capacity of muscle cells in various in-vivo conditions. It is impo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.050
更新日期:2016-12-08 00:00:00
abstract::Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.001
更新日期:2006-01-01 00:00:00
abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90170-4
更新日期:1988-01-01 00:00:00
abstract::Multi-segment models of the foot have been proposed in the past years to overcome limitations imposed by oversimplified traditional approaches used to describe foot kinematics, but they have been only partially validated and never compared. This paper presents a unique comparative assessment of the four most widely ad...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.07.041
更新日期:2016-10-03 00:00:00
abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00130-1
更新日期:2003-10-01 00:00:00