An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

Abstract:

:Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomechanical analysis. In this study, it was aimed to quantify the relationship between venous sound and CP dehiscence/thinness using in vitro experiment. The in vitro models of SS and CP were established based on 3D-printing, with the developed pulsatile venous flow in the SS model. The generated sound signal and the vibration response at the dehiscent/thinned area were analyzed. The sound signal generated in the normal-sized dehiscence model was pulse-synchronous within 100--400 Hz, which had similar acoustic characteristics as the clinical PT sounds. It was concluded that the pulsatile venous sound is produced at TS-SS junction in case of CP dehiscence. The CP, even a thinned one can effectively diminish the venous sound and sound-generating pulsatile vibration at TS-SS junction. The CP dehiscence would induce pulse-synchronous and high pressure venous sound, as well as pulse-synchronous vibration above 20 Hz, regardless of the dehiscence size. On the contrary, the CP thinness would not induce obvious venous sound or pulsatile vibration above 20 Hz.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Tian S,Fan X,Wang Y,Liu Z,Wang L

doi

10.1016/j.jbiomech.2018.12.049

subject

Has Abstract

pub_date

2019-02-14 00:00:00

pages

197-203

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30013-2

journal_volume

84

pub_type

杂志文章
  • A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

    abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90022-7

    authors: Lippert FG 3rd,Harrington RM,Veress SA,Fraser C,Green D,Bahniuk E

    更新日期:1982-01-01 00:00:00

  • Compliance calibration for fracture testing of equine cortical bone.

    abstract::An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for cra...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00009-x

    authors: Malik CL,Gibeling JC,Martin RB,Stover SM

    更新日期:2002-05-01 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • Shoulder labral pathomechanics with rotator cuff tears.

    abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.036

    authors: Hwang E,Carpenter JE,Hughes RE,Palmer ML

    更新日期:2014-05-07 00:00:00

  • Bivariate optimization of pedalling rate and crank arm length in cycling.

    abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90016-4

    authors: Hull ML,Gonzalez H

    更新日期:1988-01-01 00:00:00

  • Optimization-based differential kinematic modeling exhibits a velocity-control strategy for dynamic posture determination in seated reaching movements.

    abstract::We proposed a velocity control strategy for dynamic posture determination that underlay an optimization-based differential inverse kinematics (ODIK) approach for modeling three-dimensional (3-D) seated reaching movements. In this modeling approach, a four-segment seven-DOF linkage is employed to represent the torso an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00117-1

    authors: Zhang X,Kuo AD,Chaffin DB

    更新日期:1998-11-01 00:00:00

  • On the anisotropy of the canine diaphragmatic central tendon.

    abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90289-y

    authors: Chuong CJ,Sacks MS,Johnson RL Jr,Reynolds R

    更新日期:1991-01-01 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Mechanisms of female urinary continence under stress: frequency spectrum analysis.

    abstract::Intravesical and urethral pressure signals during cough and Valsalva maneuvers for 15 continent women were analyzed with frequency spectrum analysis. Clear modulation of the urethral pressure changes by the intravesical pressure rise during stress maneuvers was demonstrated in the frequency bands of 14 and 7 Hz for co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00006-9

    authors: Kim K,Jurnalov CD,Ham S,Webb MJ,An K

    更新日期:2001-05-01 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • Sarcomere dynamics in skeletal muscle myofibrils during isometric contractions.

    abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.011

    authors: Pavlov I,Novinger R,Rassier DE

    更新日期:2009-12-11 00:00:00

  • Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique.

    abstract::The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.003

    authors: Goodship AE,Birch HL

    更新日期:2005-03-01 00:00:00

  • A parametric model for studying the aorta hemodynamics by means of the computational fluid dynamics.

    abstract::Perturbed aorta hemodynamics, as for the carotid and the coronary artery, has been identified as potential predicting factor for cardiovascular diseases. In this study, we propose a parametric study based on the computational fluid dynamics with the aim of providing information regarding aortic disease. In particular,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109691

    authors: Cilla M,Casales M,Peña E,Martínez MA,Malvè M

    更新日期:2020-04-16 00:00:00

  • Coactivation of jaw muscles: recruitment order and level as a function of bite force direction and magnitude.

    abstract::The aim of this study was to obtain insight into the coactivation behaviour of the jaw muscles under various a priori defined static loading conditions of the mandible. As the masticatory system is mechanically redundant, an infinite number of recruitment patterns is theoretically possible to produce a certain bite fo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90303-k

    authors: Van Eijden TM,Brugman P,Weijs WA,Oosting J

    更新日期:1990-01-01 00:00:00

  • Chest response assessment of post-mortem swine under blast loadings.

    abstract::To better protect soldiers from blast threat, that principally affect air-filled organs such a lung, it is necessary to develop an adapted injury criterion and, prior to this, to evaluate the response of a biological model against that threat. The objective of this study is to provide some robust data to quantify the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.012

    authors: Boutillier J,De Mezzo S,Deck C,Magnan P,Naz P,Willinger R

    更新日期:2017-12-08 00:00:00

  • A laser-aligned method for anthropometry of hands.

    abstract::We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00121-0

    authors: Highton J,Davidson P,Markham V

    更新日期:2003-09-01 00:00:00

  • Effects of short-term recovery periods on fluid-induced signaling in osteoblastic cells.

    abstract::It is well known that cyclic mechanical loading can produce an anabolic response in bone. In vivo studies have shown that the insertion of short-term recovery periods (10-15 s) into mechanical loading profiles led to an increased osteogenic response compared to continuous cyclic loading of bone. Although this is sugge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.08.009

    authors: Batra NN,Li YJ,Yellowley CE,You L,Malone AM,Kim CH,Jacobs CR

    更新日期:2005-09-01 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Bisphosphonate treatment in the oim mouse model alters bone modeling during growth.

    abstract::Osteogenesis imperfecta (OI) is a heritable disease, which results from an abnormal amount or structure of Type I collagen. Bisphosphonates, a class of synthetic antiresorptive drugs, used in osteoporosis management, are also used to decrease fracture incidence and improve quality of life in children with OI. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.028

    authors: Rao SH,Evans KD,Oberbauer AM,Martin RB

    更新日期:2008-12-05 00:00:00

  • Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

    abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.047

    authors: Janiga G,Rössl C,Skalej M,Thévenin D

    更新日期:2013-01-04 00:00:00

  • On practical evaluation of differentiation techniques for human gait analysis.

    abstract::Numerical differentiation of noisy measurement data represents a problem frequently encountered in the field of gait analysis. There are two major determinants of the quality in calculated derivatives, namely the quality of the measurement data and the quality of the used differentiation technique. The quality of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90041-0

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • The influence of strain rate on adaptive bone remodelling.

    abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90092-6

    authors: O'Connor JA,Lanyon LE,MacFie H

    更新日期:1982-01-01 00:00:00

  • A technique for the tensile testing of demineralised bone.

    abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90365-l

    authors: Jonas J,Burns J,Abel EW,Cresswell MJ,Strain JJ,Paterson CR

    更新日期:1993-03-01 00:00:00

  • Effects of intervertebral disc lesion and multifidus muscle resection on the structure of the lumbar intervertebral discs and paraspinal musculature of the rat.

    abstract::The aim of this study was to investigate whether elimination of multifidus muscle in rats causes intervertebral disc (IVD) degeneration similar to that found after IVD lesion. Data were obtained from 36 male Wistar rats randomly assigned to one of three groups: (i) IVD lesion, in which the L4/L5 IVD was stabbed; (ii) ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.004

    authors: Maas H,Noort W,Hodges PW,van Dieën J

    更新日期:2018-03-21 00:00:00

  • Biomechanical evaluation of walking and cycling in children.

    abstract::Physical activity in children is important as it leads to healthy growth due to physiological benefits. However, a physiological benefit can be partially negated by excessive or unphysiological loads within the joints. To gain an initial understanding into this, the present study sought to compare joint loading betwee...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.051

    authors: Greca JPA,Ryan J,Baltzopoulos V,Korff T

    更新日期:2019-04-18 00:00:00

  • Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics.

    abstract::To date, the diagnosis of whiplash injuries has been very difficult and largely based on subjective, clinical assessment. The work by Winters and Peles Multiple Muscle Systems--Biomechanics and Movement Organization. Springer, New York (1990) suggests that the use of finite helical axes (FHAs) in the neck may provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90192-9

    authors: Woltring HJ,Long K,Osterbauer PJ,Fuhr AW

    更新日期:1994-12-01 00:00:00

  • Mass properties of the human mandible.

    abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00057-x

    authors: Zhang F,Peck CC,Hannam AG

    更新日期:2002-07-01 00:00:00

  • Comparative left-right mechanical testing of cancellous bone from normal femoral heads.

    abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00061-9

    authors: Banse X,Delloye C,Cornu O,Bourgois R

    更新日期:1996-10-01 00:00:00

  • Simulation of Low Density Lipoprotein (LDL) permeation into multilayer coronary arterial wall: Interactive effects of wall shear stress and fluid-structure interaction in hypertension.

    abstract::Due to increased atherosclerosis-caused mortality, identification of its genesis and development is of great importance. Although, key factors of the origin of the disease is still unknown, it is widely believed that cholesterol particle penetration and accumulation in arterial wall is mainly responsible for further w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.029

    authors: Roustaei M,Nikmaneshi MR,Firoozabadi B