Abstract:
:Groups of rats were killed at 2, 6, 12, and 24 months of age. From dissected left and right mandibles in each rat, three pairs of transverse sections were cut at the incisal, middle, and basal regions of the incisor. One section in each pair was loaded until failure and a stress-strain curve for the periodontal ligament (PDL) was obtained. The other section was loaded to up to 50% of the maximum shear stress as determined from the contralateral section and then kept at a constant strain for 10 min, to obtain the stress-relaxation curve at the same region of the PDL. The maximum shear stress and toughness increased with age at the incisal region and the maximum shear strain increased with age at the incisal and middle regions. The tangent modulus decreased with advancing age at the middle region. The stress-relaxation during 10 min decreased with advancing age at the incisal and basal regions, but not at the middle region. The relaxation process was well described by a sum of three exponential decay functions, reflecting the short-, medium-, and long-term relaxation components. The age-related decrease in the relaxation was mainly attributable to increases in the ratio and relaxation time of the long-term relaxation component. These results suggest that with advancing age the mechanical strength and toughness of the PDL are enhanced mostly at the incisal region and that the viscous fraction is relatively decreased at the incisal and basal regions along the long axis of the rat incisor.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Komatsu K,Shibata T,Shimada A,Viidik A,Chiba Mdoi
10.1016/j.jbiomech.2003.11.013keywords:
subject
Has Abstractpub_date
2004-07-01 00:00:00pages
1097-106issue
7eissn
0021-9290issn
1873-2380pii
S0021929003004251journal_volume
37pub_type
杂志文章abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.08.003
更新日期:2006-01-01 00:00:00
abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90049-3
更新日期:1994-11-01 00:00:00
abstract::Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect are...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.03.019
更新日期:2013-05-31 00:00:00
abstract::Electromagnetic tracking devices are used in many biomechanics applications. Previous studies have shown that metal located within the working field of direct current electromagnetic tracking devices produces significant errors. However, the effect of sampling rate on the errors produced in a metallic environment has ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00322-6
更新日期:2003-01-01 00:00:00
abstract::Although biomechanical studies of the normal rat vein wall have been reported (Weizsacker, 1988; Plante, 2002), there are no published studies that have investigated the mechanical effects of thrombus formation on murine venous tissue. In response to the lack of knowledge concerning the mechanical consequences of thro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.012
更新日期:2010-11-16 00:00:00
abstract::This paper deals with the analysis of human arm movement in a crank-rotation task that is an example of environmentally constrained movements. Opening a door, rotating a steering wheel, and pushing a carriage are other typical examples of movements where the physical constraints, imposed on the hand position/orientati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.034
更新日期:2016-09-06 00:00:00
abstract::The effect of screw-bone interface modelling strategies was evaluated in the setting of a tibial mid-shaft fracture stabilised using locking plates. Three interface models were examined: fully bonded interface; screw with sliding contact with bone; and screw with sliding contact with bone in an undersized pilot hole. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.008
更新日期:2012-06-01 00:00:00
abstract::We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-sp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.06.031
更新日期:2012-09-21 00:00:00
abstract::The purpose of this study was to examine the relationship between internal force production in selected skeletal muscles and the externally calculated joint moment during overground locomotion in the adult cat. Hindlimb segments were modelled as a linked system of rigid bodies and a generalized muscle moment (GMM), th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90010-c
更新日期:1993-04-01 00:00:00
abstract::Plastic deformation of sutures creates an irreversible extension during load. To test our hypothesis that such plastic deformation causes gap formation after tendon repair, we determined the plasticity of five different suture materials commonly used in tendon surgery. Prolene, Polydioxanone (PDS), Ethibond, Vicryl, a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.023
更新日期:2016-09-06 00:00:00
abstract::Pedicle-screw-based motion preservation systems are often used to support a slightly degenerated disc. Such implants are intended to reduce intradiscal pressure and facet joints forces, while having a minimal effect on the motion patterns. In a probabilistic finite element study with subsequent sensitivity analysis, t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.018
更新日期:2010-11-16 00:00:00
abstract::The thoracolumbar fascia (TLF) provides a means of attachment to the lumbar spine for several muscles including the transverse abdominis, and parts of the latissimus dorsi and internal oblique muscles. Previous biomechanical models of the lumbar spine either tend to omit the TLF on the assumption that its contribution...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.022
更新日期:2010-10-19 00:00:00
abstract::The purpose of this study was to investigate the effect of the differences between the actual fascicle length during a voluntary contraction and the fascicle length at rest of the triceps surae muscle on the determination of the voluntary activation (VA) by using the interpolated twitch technique. Twelve participants ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.04.011
更新日期:2007-01-01 00:00:00
abstract::Dynamic stabilization devices have been introduced to clinics as an alternative to rigid fixation. The stiffness of these devices varies widely, whereas the optimal stiffness, achieving a predefined stabilization of the spine, is unknown. This study was focused on the determination of stiffness values for posterior st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.005
更新日期:2009-01-05 00:00:00
abstract::Perturbed aorta hemodynamics, as for the carotid and the coronary artery, has been identified as potential predicting factor for cardiovascular diseases. In this study, we propose a parametric study based on the computational fluid dynamics with the aim of providing information regarding aortic disease. In particular,...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109691
更新日期:2020-04-16 00:00:00
abstract::The goal of the present study was to assess the effects of age and sex on trunk motor control. Fifty healthy adults (aged between 19 and 67 years, 28 males) participated in this study. Trunk motor control was assessed using force-controlled perturbations directly applied to the trunk. Admittance (inverse of lumped int...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109607
更新日期:2020-03-26 00:00:00
abstract::The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.04.021
更新日期:2009-07-22 00:00:00
abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.05.010
更新日期:2013-07-26 00:00:00
abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90237-0
更新日期:1988-01-01 00:00:00
abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.044
更新日期:2017-08-16 00:00:00
abstract::In this study, we proposed a novel approach to assess the energy dissipation during the post-yield deformation of bone. Based on the stress-strain behavior in an incremental and cyclic loading-unloading-reloading scheme in uniaxial tension, we partitioned the post-yield energy dissipation of bone into three distinct p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.02.002
更新日期:2007-01-01 00:00:00
abstract::A new strain energy function for the hyperelastic modelling of ligaments and tendons based on the geometrical arrangement of their fibrils is derived. The distribution of the crimp angles of the fibrils is used to determine the stress-strain response of a single fascicle, and this stress-strain response is used to det...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.11.031
更新日期:2015-01-21 00:00:00
abstract::The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110050
更新日期:2020-11-09 00:00:00
abstract::Radioembolization, which consist of the implantation of radioactive microspheres via intra-arterially placed microcatheter, is a safe and effective treatment for liver cancer. Nevertheless, radioembolization-related complications and side effects may arise, which are an active area of ongoing research. The catheter de...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.09.035
更新日期:2016-11-07 00:00:00
abstract::In this study, we tested the compressive stress relaxation behaviors of the mandibular condylar and temporal cartilages in the porcine temporomandibular joint (TMJ). The aim was to determine the quantitative and qualitative similarities and differences of compressive stress relaxation behaviors between the two cartila...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.007
更新日期:2014-05-07 00:00:00
abstract::Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.011
更新日期:2011-02-03 00:00:00
abstract::When balance is disturbed, location of the center of pressure (COP) contributes to a person's ability to recover from a perturbation. This study investigated COP control prior to first step lift-off (FSLO) during lateral perturbations in older non-fallers and fallers. 38 non-fallers and 16 fallers received lateral wai...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.012
更新日期:2015-04-13 00:00:00
abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109344
更新日期:2019-11-11 00:00:00
abstract::Rabbits were immobilized for 3 weeks with the ankle in plantar flexion, midrange position or dorsal extension (n=15). The left leg was used as control. Sarcomere lengths were measured by laser diffraction in vivo in the tibialis anterior (TA) muscle. Legs immobilized in the midrange position showed coherent diffractio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.006
更新日期:2008-01-01 00:00:00
abstract::Simple models are widely used to understand the mechanics of human walking. The optimization-based minimal biped model and spring-loaded-inverted-pendulum (SLIP) model are two popular models that can achieve human-like walking patterns. However, ground reaction forces (GRF) from these two models still deviate from exp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.028
更新日期:2019-06-11 00:00:00