Which axial and bending stiffnesses of posterior implants are required to design a flexible lumbar stabilization system?

Abstract:

:Dynamic stabilization devices have been introduced to clinics as an alternative to rigid fixation. The stiffness of these devices varies widely, whereas the optimal stiffness, achieving a predefined stabilization of the spine, is unknown. This study was focused on the determination of stiffness values for posterior stabilization devices achieving a flexible, semi-flexible or rigid connection between two vertebrae. An extensively validated finite element model of a lumbar spinal segment L4-5 with an implanted posterior fixation device was used in this study. The model was exposed to pure moments of 7.5 and 20Nm around the three principal anatomical directions, simulating flexion, extension, lateral bending and axial rotation. In parametrical studies, the influence of the axial and bending fixator stiffness on the spinal range of motion was investigated. In order to examine the validity of the computed results, an in-vitro study was carried out. In this, the influence of two posterior stabilization devices (DSS and rigidly internal fixator) on the segmental stabilization was investigated. The finite element (FE)-model predicted that each load direction caused a pairing of stiffness relations between axial and bending stiffness. In flexion and extension, however, the bending stiffness had a neglectable effect on the segmental stabilization, compared to the axial stiffness. In contrast, lateral bending and axial rotation were influenced by both stiffness parameters. Except in axial rotation, the model predictions were in a good agreement with the determined in-vitro data. In axial rotation, the FE-model predicted a stiffer segmental behavior than it was determined in the in-vitro study. It is usually expected that high stiffness values are required for a posterior stabilization device to stiffen a spinal segment. We found that already small stiffness values were sufficient to cause a stiffening. Using these data, it may possible to develop implants for certain clinical indications.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Schmidt H,Heuer F,Wilke HJ

doi

10.1016/j.jbiomech.2008.10.005

subject

Has Abstract

pub_date

2009-01-05 00:00:00

pages

48-54

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(08)00509-5

journal_volume

42

pub_type

杂志文章
  • Biaxial anisotropy of dog carotid artery: estimation of circumferential elastic modulus.

    abstract::Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90011-4

    authors: Dobrin PB

    更新日期:1986-01-01 00:00:00

  • The three-dimensional determination of internal loads in the lower extremity.

    abstract::A three-dimensional model of the lower limb containing 47 muscles was developed to study the differences between a two- and three-dimensional approach for determining internal loads, the role of the dynamic joint representation, and the behavior of different load-bearing criteria in walking and running. The problem of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00089-4

    authors: Glitsch U,Baumann W

    更新日期:1997-11-01 00:00:00

  • Residual force enhancement during submaximal and maximal effort contractions of the plantar flexors across knee angle.

    abstract::Following active muscle lengthening, steady-state isometric force is elevated compared with an isometric contraction without prior lengthening for the same muscle length and activation level. This property of muscle contraction is known as residual force enhancement (RFE). Here, we aimed to determine whether neural fa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.019

    authors: Dalton BH,Contento VS,Power GA

    更新日期:2018-09-10 00:00:00

  • Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment.

    abstract::The drop vertical jump (DVJ) task is commonly used to assess biomechanical performance measures that are associated with ACL injury risk in athletes. Previous investigations have solely assessed the first landing phase. We examined the first and second landings of a DVJ for differences in the magnitude of vertical gro...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.02.024

    authors: Bates NA,Ford KR,Myer GD,Hewett TE

    更新日期:2013-04-26 00:00:00

  • An analytical study on the thermal effects of cryosurgery on selective cell destruction.

    abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.005

    authors: Chua KJ,Chou SK,Ho JC

    更新日期:2007-01-01 00:00:00

  • Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

    abstract::Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.030

    authors: Ikeda J,Zhao C,Chen Q,Thoreson AR,An KN,Amadio PC

    更新日期:2011-06-03 00:00:00

  • Comparison of models for flow induced deformation of soft biological tissue.

    abstract::The behaviour of a deformable porous medium during the flow of fluid under a pressure difference is examined for both infinitesimal and finite deformations. Models for both cases are solved for the problem of steady one-dimensional compression and compared with experimental data from Parker et al. (J. appl. Mech. 54, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90164-x

    authors: Barry SI,Aldis GK

    更新日期:1990-01-01 00:00:00

  • The mechanics of atherosclerotic plaque rupture by inclusion/matrix interfacial decohesion.

    abstract::Histological investigation along with finite element analysis of arterial wall/atherosclerotic plaque geometries indicates the paradoxical result that ruptures often occur at sites with predicted stresses of half the plaque cap strength. Recent experiments have revealed calcified cells within the cap suggesting that t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.012

    authors: Nguyen CM,Levy AJ

    更新日期:2010-10-19 00:00:00

  • A comparison of methods to quantify control of the spine.

    abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109344

    authors: Bourdon E,Graham RB,van Diëen J

    更新日期:2019-11-11 00:00:00

  • Articular contact in a three-dimensional model of the knee.

    abstract::This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different mathematical conta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90019-j

    authors: Blankevoort L,Kuiper JH,Huiskes R,Grootenboer HJ

    更新日期:1991-01-01 00:00:00

  • Lumbar muscle force estimation using a subject-invariant 5-parameter EMG-based model.

    abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00055-4

    authors: Nussbaum MA,Chaffin DB

    更新日期:1998-07-01 00:00:00

  • Crack growth resistance in cortical bone: concept of microcrack toughening.

    abstract::The role of microcracking in cortical bone as a toughening mechanism has been investigated in conjunction with the variation in fracture toughness with crack length. Fracture toughness tests were conducted on miniaturised compact tension specimens made from human and bovine cortical bone and the resultant microstructu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00029-8

    authors: Vashishth D,Behiri JC,Bonfield W

    更新日期:1997-08-01 00:00:00

  • Runners adjust leg stiffness for their first step on a new running surface.

    abstract::Human runners adjust the stiffness of their stance leg to accommodate surface stiffness during steady state running. This adjustment allows runners to maintain similar center of mass movement (e.g., ground contact time and stride frequency) regardless of surface stiffness. When runners encounter abrupt transitions in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(99)00078-0

    authors: Ferris DP,Liang K,Farley CT

    更新日期:1999-08-01 00:00:00

  • Classification of errors in locating a rigid body.

    abstract::This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimension...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00008-5

    authors: Ball KA,Pierrynowski MR

    更新日期:1996-09-01 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • The effects of tensile-compressive loading mode and microarchitecture on microdamage in human vertebral cancellous bone.

    abstract::The amount of microdamage in bone tissue impairs mechanical performance and may act as a stimulus for bone remodeling. Here we determine how loading mode (tension vs. compression) and microstructure (trabecular microarchitecture, local trabecular thickness, and presence of resorption cavities) influence the number and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.011

    authors: Lambers FM,Bouman AR,Tkachenko EV,Keaveny TM,Hernandez CJ

    更新日期:2014-11-28 00:00:00

  • Quantifying the history dependency of muscle recovery from a fatiguing intermittent task.

    abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.061

    authors: Rashedi E,Nussbaum MA

    更新日期:2017-01-25 00:00:00

  • Isolated changes in femoral version do not alter intra-articular contact mechanics in cadaveric hips.

    abstract::Abnormal femoral version is a deformity in the angle between the femoral neck and the transcondylar axis of the knee. Both femoral anteversion and retroversion alter passive and active rotation of the hip and are associated with intra-articular or extra-articular impingement. However, little is known about the effect ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109891

    authors: Meyer AM,Thomas-Aitken HD,Brouillette MJ,Westermann RW,Goetz JE

    更新日期:2020-08-26 00:00:00

  • Inter- and intra-rater reliability of 3D kinematics during maximum mouth opening of asymptomatic subjects.

    abstract::Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (S...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.038

    authors: Calixtre LB,Nakagawa TH,Alburquerque-Sendín F,da Silva Grüninger BL,de Sena Rosa LR,Oliveira AB

    更新日期:2017-11-07 00:00:00

  • Age-related and regional differences in the stress-strain and stress-relaxation behaviours of the rat incisor periodontal ligament.

    abstract::Groups of rats were killed at 2, 6, 12, and 24 months of age. From dissected left and right mandibles in each rat, three pairs of transverse sections were cut at the incisal, middle, and basal regions of the incisor. One section in each pair was loaded until failure and a stress-strain curve for the periodontal ligame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.11.013

    authors: Komatsu K,Shibata T,Shimada A,Viidik A,Chiba M

    更新日期:2004-07-01 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Effects of patella alta and patella infera on patellofemoral contact forces.

    abstract::The relationship between patella alta and patellar subluxation may, in part, reflect the relationship between the height of the patella above the tibiofemoral joint line and the patellofemoral contact force. This study reports on the direct in vitro measurement of the patellofemoral contact force, and its point of app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90222-4

    authors: Singerman R,Davy DT,Goldberg VM

    更新日期:1994-08-01 00:00:00

  • Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints.

    abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.024

    authors: Drewniak EI,Jay GD,Fleming BC,Crisco JJ

    更新日期:2009-08-25 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • The consequences of dehydration-hydration on bone anisotropy and implications on the sublamellar organization of mineralized collagen fibrils.

    abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109737

    authors: Utku FS

    更新日期:2020-05-07 00:00:00

  • Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress.

    abstract::While there are a growing number of increasingly complex methodologies available to model geometry and material properties of bones, these models still cannot accurately describe physical behaviour of the skeletal system unless the boundary conditions, especially muscular loading, are correct. Available in vivo measur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.049

    authors: Sverdlova NS,Witzel U

    更新日期:2010-02-10 00:00:00

  • The effect of centre of mass location on sagittal plane moments around the centre of mass in trotting horses.

    abstract::The diagonal limb support pattern at trot provides pitch and roll stability, but little is known about the control of moments about the centre of mass (COM) in horses. Correct COM location is critical in the calculation of pitching moments. The objectives were to determine the effect of COM location on pitching moment...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.024

    authors: Hobbs SJ,Richards J,Clayton HM

    更新日期:2014-04-11 00:00:00

  • Force depression following muscle shortening in sub-maximal voluntary contractions of human adductor pollicis.

    abstract::Mechanical properties of skeletal muscles are often studied for controlled, electrically induced, maximal, or supra-maximal contractions. However, many mechanical properties, such as the force-length relationship and force enhancement following active muscle stretching, are quite different for maximal and sub-maximal,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.002

    authors: Rousanoglou EN,Oskouei AE,Herzog W

    更新日期:2007-01-01 00:00:00

  • An equation to calculate individual muscle contributions to joint stability.

    abstract::The purpose of the current paper was to use the energy approach to develop a simplified equation for quantifying individual muscle contributions to mechanical stability about all three axes of a particular joint. Specific examples are provided for muscles acting about the lumbar spine's L4/L5 joint. The stability equa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.004

    authors: Potvin JR,Brown SH

    更新日期:2005-05-01 00:00:00