Classification of errors in locating a rigid body.

Abstract:

:This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimensional observed points, the RB fit of those points, and the estimation of true RB positions, respectively. Of these, the theoretical error is most critical and most pivotal. Accuracy is provided when the theoretical error is minimised, yet only the measured error can be minimised by RB modelling algorithms. In computer simulations one may determine the effect that such manipulations have on theoretical error, yet in most experimental conditions this value may not even be calculated. Fortunately, computer simulations can be performed to determine the inter-relationships between types of RB modelling errors. Such simulations can also be used to investigate the effects of RB shape. In this paper, Monte Carlo simulations were performed on three unit radius RBs; a triangle, a square and a tetrahedron. Although the use of the triangle provided the lowest measured error, this also coincided with the greatest theoretical error. The use of redundant points was found to yield superior theoretical accuracies. A slight advantage was gained with use of the non-planar point arrangement on the tetrahedron, both the measured and theoretical errors were reduced. Finally, the superiority of RB modelling over individual point tracking was reflected in all of the results; between 33 and 50% of the input error was eliminated with the use of RB modelling.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Ball KA,Pierrynowski MR

doi

10.1016/0021-9290(96)00008-5

subject

Has Abstract

pub_date

1996-09-01 00:00:00

pages

1213-7

issue

9

eissn

0021-9290

issn

1873-2380

pii

0021929096000085

journal_volume

29

pub_type

杂志文章
  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00

  • The human ankle during walking: implications for design of biomimetic ankle prostheses.

    abstract::The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.017

    authors: Hansen AH,Childress DS,Miff SC,Gard SA,Mesplay KP

    更新日期:2004-10-01 00:00:00

  • Regional contribution of proteoglycans to the fracture toughness of the dentin extracellular matrix.

    abstract::This study investigated the contribution of small leucine rich proteoglycans (SLRPs) to the fracture toughness of the dentin extracellular matrix (ECM) by enzymatically-assisted selective removal of glycosaminoglycan chains (GAGs) and proteoglycans (PGs) core protein. We adapted the Mode III trouser tear test to evalu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109633

    authors: Alania Y,Creighton J,Trevelin LT,Zamperini CA,Bedran-Russo AK

    更新日期:2020-03-05 00:00:00

  • Exercise-induced hyperthermia as a possible mechanism for tendon degeneration.

    abstract::Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90262-3

    authors: Wilson AM,Goodship AE

    更新日期:1994-07-01 00:00:00

  • Measurement of whole-body vibration by double-pulsed holography.

    abstract::A technique for registering vibration and deformation patterns has been adapted for the measurement of whole-body vibration in humans. Double-exposure holographic interferometry produces three dimensional pictures of the body, allowing exact measurement of the subject's movement between the two pulses. In this study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90036-8

    authors: Wangenheim M,Holzmann P,Svensson LB

    更新日期:1984-01-01 00:00:00

  • Constrained least-squares optimization for robust estimation of center of rotation.

    abstract::This paper presents a new direct method for estimating the average center of rotation (CoR). An existing least-squares (LS) solution has been shown by previous works to have reduced accuracy for data with small range of motion (RoM). Alternative methods proposed to improve the CoR estimation use iterative algorithms. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.010

    authors: Chang LY,Pollard NS

    更新日期:2007-01-01 00:00:00

  • Numerical errors and uncertainties in finite-element modeling of trabecular bone.

    abstract::Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00108-0

    authors: Ladd AJ,Kinney JH

    更新日期:1998-10-01 00:00:00

  • Mechanics of toe and heel landing in stepping down in ongoing gait.

    abstract::When stepping down from a height difference in ongoing gait, subjects are known to use a heel landing at small height differences and switch to toe landing for larger height differences. We hypothesized that in toe landing, the leading leg can perform more negative work, to control the momentum gained during the desce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.022

    authors: van Dieën JH,Spanjaard M,Könemann R,Bron L,Pijnappels M

    更新日期:2008-08-07 00:00:00

  • Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

    abstract::The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90006-7

    authors: DiAngelo DJ,Winter DA,Ghista DN,Newcombe WR

    更新日期:1989-01-01 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Simulation of quadrupedal locomotion using a rigid body model.

    abstract::Locomotion of the horse is simulated using a mathematical model based on rigid body dynamics. A general method to generate the equations of motion for a two-dimensional rigid body model with an arbitrary number of hinge joints is presented and a numerical solution method, restricted to tree-structured models, is descr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90182-6

    authors: van den Bogert AJ,Schamhardt HC,Crowe A

    更新日期:1989-01-01 00:00:00

  • Passive stress-strain relation for the right ventricle in diastole.

    abstract::Wall thickness and medial line radii of an in vitro canine heart are measured. These data are assumed to be characteristic of the in vivo ventricles subject to zero pressure, and in the absence of filling. The myocardium is taken to be homogeneous, isotropic, non-linearly elastic, and incompressible. The right ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90171-3

    authors: Moskowitz SE

    更新日期:1982-01-01 00:00:00

  • Comparative left-right mechanical testing of cancellous bone from normal femoral heads.

    abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00061-9

    authors: Banse X,Delloye C,Cornu O,Bourgois R

    更新日期:1996-10-01 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • Using smart garments to differentiate among normal and simulated abnormal gaits.

    abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2019.06.009

    authors: Mokhlespour Esfahani MI,Nussbaum MA

    更新日期:2019-08-27 00:00:00

  • Enhanced global mathematical model for studying cerebral venous blood flow.

    abstract::Here we extend the global, closed-loop, mathematical model for the cardiovascular system in Müller and Toro (2014) to account for fundamental mechanisms affecting cerebral venous haemodynamics: the interaction between intracranial pressure and cerebral vasculature and the Starling-resistor like behaviour of intracrani...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.005

    authors: Müller LO,Toro EF

    更新日期:2014-10-17 00:00:00

  • Location of minimum foot clearance on the shoe and with respect to the obstacle changes with locomotor task.

    abstract::Minimum foot clearance (MFC) as it relates to trips and falls has been extensively studied across many locomotor tasks, but examination of this body of research yields several studies with conflicting results and a wide range of MFCs within tasks. While there are several factors that may affect the MFC variability acr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.002

    authors: Loverro KL,Mueske NM,Hamel KA

    更新日期:2013-07-26 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • Study on modelling of PMMA bone cement polymerisation.

    abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.021

    authors: Stańczyk M

    更新日期:2005-07-01 00:00:00

  • Influence of erythrocyte aggregation on radial migration of platelet-sized spherical particles in shear flow.

    abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.044

    authors: Guilbert C,Chayer B,Allard L,Yu FTH,Cloutier G

    更新日期:2017-08-16 00:00:00

  • The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

    abstract::Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.034

    authors: Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

    更新日期:2015-06-01 00:00:00

  • Mitogen-activated protein kinase signaling in bovine articular chondrocytes in response to fluid flow does not require calcium mobilization.

    abstract::In the present study, the role of mitogen-activated protein kinases (MAPKs) in chondrocyte mechanotransduction was investigated. We hypothesized that MAPKs participate in fluid flow-induced chondrocyte mechanotransduction. To test our hypothesis, we studied cultured chondrocytes subjected to a well-defined mechanical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00176-1

    authors: Hung CT,Henshaw DR,Wang CC,Mauck RL,Raia F,Palmer G,Chao PH,Mow VC,Ratcliffe A,Valhmu WB

    更新日期:2000-01-01 00:00:00

  • Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

    abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.003

    authors: Nawayseh N,Hamdan S

    更新日期:2019-01-03 00:00:00

  • Is staircase walking a risk for the fixation of hip implants?

    abstract::Considerable forces and moments act at hip prostheses during most kinds of physical activities. High torque around the stem axis may contribute to implant loosening. With instrumented hip prostheses the joint force and its direction, the bending moment in the frontal plane and the torque were measured in two patients ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00105-d

    authors: Bergmann G,Graichen F,Rohlmann A

    更新日期:1995-05-01 00:00:00

  • Calculation of impingement-free combined cup and stem alignments based on the patient-specific pelvic tilt.

    abstract::Proper cup alignment is crucial in total hip arthroplasty for reducing impingement risks, dislocations and wear. The Lewinnek "safe zone" is often used in clinical routine. This safe zone does not consider functional aspects and dislocation can occur even when the cup is oriented within the safe zone. Functional safe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.020

    authors: Hsu J,de la Fuente M,Radermacher K

    更新日期:2019-01-03 00:00:00

  • A dynamic model of the forearm including fatigue.

    abstract::A biomechanical model of the forearm, consisting of 61 muscle-tendon systems or tendons and 8 sections, is presented. The model can be used to calculate the muscle forces when resultant of the external forces and the motion is known. Calculations are based on constraints of muscle forces, joint forces, contact forces,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00009-4

    authors: Freund J,Takala EP

    更新日期:2001-05-01 00:00:00

  • Optimization-based differential kinematic modeling exhibits a velocity-control strategy for dynamic posture determination in seated reaching movements.

    abstract::We proposed a velocity control strategy for dynamic posture determination that underlay an optimization-based differential inverse kinematics (ODIK) approach for modeling three-dimensional (3-D) seated reaching movements. In this modeling approach, a four-segment seven-DOF linkage is employed to represent the torso an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00117-1

    authors: Zhang X,Kuo AD,Chaffin DB

    更新日期:1998-11-01 00:00:00