Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

Abstract:

:Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates the effect of bending the knees and the vibration frequency on the interface force (presented as apparent mass (AM)) between the vibrating plate and the body. Twelve male subjects stood with four different knee angles (180, 165, 150 and 135°) and were exposed to sinusoidal vertical vibration at eight frequencies in the range of 17-42 Hz. The vertical acceleration and the interface force between the body and the vibrating plate were measured and used to calculate the AM. The acceleration and force depended on the frequency and were found to vary with both the adopted posture and subject. The AM generally decreased with increasing the frequency but showed a peak at 24 Hz which was clearer when the knees were bent. Bending the knees showed an effect similar to increasing the damping of a system with base excitation; increasing the damping reduced the AM in the resonance region but increased the AM at higher frequencies. Users of WBVTMs have to be careful when choosing the training posture: although, as shown in previous studies, bending the knees reduces the transmission of vibration to the spine, it increases the interface forces which might indicate increased stresses on the lower legs and joints.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Nawayseh N,Hamdan S

doi

10.1016/j.jbiomech.2018.11.003

subject

Has Abstract

pub_date

2019-01-03 00:00:00

pages

291-298

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30834-0

journal_volume

82

pub_type

杂志文章
  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • A continuous wave technique for the measurement of the elastic properties of cortical bone.

    abstract::A continuous wave technique is described for measuring the nine independent orthotropic elastic coefficients from a single cubic specimen. The side dimensions of this cubic specimen are on the order of 5 mm. Because of the small size of the specimen, the spatial resolution of material inhomogeneity using this techniqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90029-0

    authors: Ashman RB,Cowin SC,Van Buskirk WC,Rice JC

    更新日期:1984-01-01 00:00:00

  • The behavior of adaptive bone-remodeling simulation models.

    abstract::The process of adaptive bone remodeling can be described mathematically and simulated in a computer model, integrated with the finite element method. In the model discussed here, cortical and trabecular bone are described as continuous materials with variable density. The remodeling rule applied to simulate the remode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90056-7

    authors: Weinans H,Huiskes R,Grootenboer HJ

    更新日期:1992-12-01 00:00:00

  • Lumbar muscle force estimation using a subject-invariant 5-parameter EMG-based model.

    abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00055-4

    authors: Nussbaum MA,Chaffin DB

    更新日期:1998-07-01 00:00:00

  • The transmission of translational seat vibration to the head--II. Horizontal seat vibration.

    abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90170-4

    authors: Paddan GS,Griffin MJ

    更新日期:1988-01-01 00:00:00

  • A simplified model of scar contraction.

    abstract::The healing of wounds is a complex process and the contraction of the resulting scar can have a negative impact on the neighbouring skin. A finite element model of skin simulating the contraction of a scar and deformation of the surrounding skin is presented. The skin is represented by an orthotropic-viscoelastic cons...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.024

    authors: Flynn C,McCormack BA

    更新日期:2008-01-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • A force plate study of avian gait.

    abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.014

    authors: Corr SA,McCorquodale C,McDonald J,Gentle M,McGovern R

    更新日期:2007-01-01 00:00:00

  • Inter- and intra-rater reliability of 3D kinematics during maximum mouth opening of asymptomatic subjects.

    abstract::Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (S...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.038

    authors: Calixtre LB,Nakagawa TH,Alburquerque-Sendín F,da Silva Grüninger BL,de Sena Rosa LR,Oliveira AB

    更新日期:2017-11-07 00:00:00

  • The effect of hip flexion angle on muscle elongation of the hip adductor muscles during stretching.

    abstract::In order to perform effective static stretching of the hip adductor muscles, it is necessary to clarify the position where the muscles are most stretched. However, the effective flexion angle in stretching for each adductor muscle remains unclear. The goal of this study was to investigate the effect of hip flexion ang...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109649

    authors: Ogawa T,Saeki J,Ichihashi N

    更新日期:2020-03-05 00:00:00

  • The effects of -80 °C short-term storage on the mechanical response of tricuspid valve leaflets.

    abstract::Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to fr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109462

    authors: Salinas SD,Clark MM,Amini R

    更新日期:2020-01-02 00:00:00

  • Simulation of quadrupedal locomotion using a rigid body model.

    abstract::Locomotion of the horse is simulated using a mathematical model based on rigid body dynamics. A general method to generate the equations of motion for a two-dimensional rigid body model with an arbitrary number of hinge joints is presented and a numerical solution method, restricted to tree-structured models, is descr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90182-6

    authors: van den Bogert AJ,Schamhardt HC,Crowe A

    更新日期:1989-01-01 00:00:00

  • Compact bone: numerical simulation of mechanical characteristics.

    abstract::One of the main difficulties encountered in the numerical simulation of the anisotropic elastic characteristics of compact bone is to account for the Haversian microstructure when determining the overall macroscopic behavior. Engineering analyses of such problems are usually based on 'homogenized approximations'. Comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90031-9

    authors: Crolet JM,Aoubiza B,Meunier A

    更新日期:1993-06-01 00:00:00

  • Tensile property of atheromatous plaque and an analysis of stress in atherosclerotic wall.

    abstract::To know the contributions of blood pressure induced stress to the progression of atherosclerosis and the rupture of atheroma, cross-sectional distributions of stresses in atherosclerotic walls were calculated by finite element method, using stress-strain data of aortic walls and atherosclerotic plaques obtained from h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00185-6

    authors: Hayashi K,Imai Y

    更新日期:1997-06-01 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running.

    abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.035

    authors: Lichtwark GA,Bougoulias K,Wilson AM

    更新日期:2007-01-01 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • Bone remodelling algorithms incorporating both strain and microdamage stimuli.

    abstract::Biomechanical theories to predict bone remodelling have used either mechanical strain or microdamage as the stimulus driving cellular responses. Even though experimental data have implicated both stimuli in bone cell regulation, a mechano-regulatory system incorporating both stimuli has not yet been proposed. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.007

    authors: McNamara LM,Prendergast PJ

    更新日期:2007-01-01 00:00:00

  • On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method.

    abstract::In recent years, computational structural analyses have emerged as important tools to investigate the mechanical response of stent placement into arterial walls. Although most coronary stents are expanded by inflating a polymeric balloon, realistic computational balloon models have been introduced only recently. In th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.027

    authors: Gervaso F,Capelli C,Petrini L,Lattanzio S,Di Virgilio L,Migliavacca F

    更新日期:2008-01-01 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Modeling aqueous humor collection from the human eye.

    abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.025

    authors: Kapnisis K,Doormaal MV,Ross Ethier C

    更新日期:2009-11-13 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis.

    abstract::To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90150-8

    authors: Chandran KB,Fatemi R,Hiratzka LF,Harris C

    更新日期:1986-01-01 00:00:00

  • 3D Imaging of vascular networks for biophysical modeling of perfusion distribution within the heart.

    abstract::One of the main determinants of perfusion distribution within an organ is the structure of its vascular network. Past studies were based on angiography or corrosion casting and lacked quantitative three dimensional, 3D, representation. Based on branching rules and other properties derived from such imaging, 3D vascula...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2012.11.027

    authors: van den Wijngaard JP,Schwarz JC,van Horssen P,van Lier MG,Dobbe JG,Spaan JA,Siebes M

    更新日期:2013-01-18 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • Compliance calibration for fracture testing of equine cortical bone.

    abstract::An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for cra...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00009-x

    authors: Malik CL,Gibeling JC,Martin RB,Stover SM

    更新日期:2002-05-01 00:00:00

  • Factors influencing performance in the Hecht vault and implications for modelling.

    abstract::This paper investigated the factors that influence Hecht vault performance and assessed the level of model complexity required to give an adequate representation of vaulting. A five-segment planar simulation model with a visco-elastic shoulder joint and a torque generator at the shoulder joint was used to simulate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.039

    authors: King MA,Yeadon MR

    更新日期:2005-01-01 00:00:00

  • Effect of foods on selected dynamic parameters of mandibular elevator muscles during symmetric incisal biting.

    abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109800

    authors: Stróżyk P,Jacek B

    更新日期:2020-06-09 00:00:00