Abstract:
:Considerable forces and moments act at hip prostheses during most kinds of physical activities. High torque around the stem axis may contribute to implant loosening. With instrumented hip prostheses the joint force and its direction, the bending moment in the frontal plane and the torque were measured in two patients during upstairs, downstairs and level walking. The data give information on whether or not stairclimbing causes a more severe loading situation for the implants than walking. While going upstairs at normal speed the joint force is 10% higher than during walking at 3 km h-1. Downstairs it increases by 20%. The bending moments change by nearly the same amounts. Upstairs the torsional moment is about twice as high as during slow walking. But walking at 5 km h-1 or slow jogging causes forces and moments of similar magnitudes. Even higher loads were observed when the patients stumbled without falling. Although torque during staircase walking is high, extreme values exclusively during stairclimbing are not confirmed by our data. The torsional moments now observed in vivo are close to or even exceed the experimentally determined limits of the torsional strength of implant fixations, found in the literature. Obviously, torsional moments play an important role for the potential loosening of hip prostheses.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Bergmann G,Graichen F,Rohlmann Adoi
10.1016/0021-9290(94)00105-dsubject
Has Abstractpub_date
1995-05-01 00:00:00pages
535-53issue
5eissn
0021-9290issn
1873-2380pii
0021-9290(94)00105-Djournal_volume
28pub_type
杂志文章abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.05.011
更新日期:2019-06-25 00:00:00
abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.036
更新日期:2014-05-07 00:00:00
abstract::The active control of the trunk plays an important role in frontal plane gait stability. We characterized trunk control in response to different step widths using a novel feedback system and examined the different effects of wide and narrow step widths as they each present unique task demands. Twenty healthy young adu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110135
更新日期:2021-01-04 00:00:00
abstract::Human crawling performance and technique are of broad interest to roboticists, biomechanists, and military personnel. This study explores the variables that define crawling performance in the context of an outdoor obstacle course used by military organizations worldwide to evaluate the effects of load and personal equ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.030
更新日期:2019-02-14 00:00:00
abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.01.018
更新日期:2009-05-29 00:00:00
abstract::Computational fluid dynamics (CFD) studies of airflow in a digital reference model of the 17-generation airway (bronchial tree) were accomplished using the FLUENT computational code, based on the anatomical model by Schmidt et al. [2004. A digital reference model of the human bronchial tree. Computerized Medical Imagi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.12.019
更新日期:2008-01-01 00:00:00
abstract::In this study, bulge inflation tests were used to characterize the failure response of 15 layers of human ascending thoracic aortic aneurysms (ATAA). Full field displacement data were collected during each of the mechanical tests using a digital image stereo-correlation (DIS-C) system. Using the collected displacement...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.12.012
更新日期:2014-02-07 00:00:00
abstract::It is generally accepted that spine control and stability are relevant for the prevention and rehabilitation of low back pain (LBP). However, there are conflicting results in the literature in regards to how these variables are modified in the presence of LBP. The aims of the present work were twofold: (1) to use noxi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.010
更新日期:2017-06-14 00:00:00
abstract::There appears a linear relationship between small increases in running speed and cardiovascular health benefits. Encouraging or coaching recreational runners to increase their running speed to derive these health benefits might be more effective if their joint level kinematic and kinetic strategy was understood. The a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.02.010
更新日期:2018-04-11 00:00:00
abstract::Tendon functionality is related to its mechanical properties. Tendon damage leads to a reduction in mechanical strength and altered biomechanical behavior, and therefore leads to compromised ability to carry out normal functions such as joint movement and stabilization. Damage can also accumulate in the tissue and lea...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.004
更新日期:2012-06-01 00:00:00
abstract::Lower propulsive joint powers, particularly at the ankle, are often observed in older compared to young adults. Interventions to increase joint powers often require labs with motion capture and force treadmill technology. Translating these interventions out of the lab requires identifying portable measures that track ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109821
更新日期:2020-06-09 00:00:00
abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.013
更新日期:2006-01-01 00:00:00
abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.05.013
更新日期:2014-08-22 00:00:00
abstract::The Global Positioning System (GPS) offers many advantages over conventional methods for the determination of subject speed during biomechanical studies. Recent advances in GPS technology, in particular the implementation of the Wide-Angle Augmentation System and European Geostationary Navigation Overlay Service (WAAS...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.07.028
更新日期:2005-08-01 00:00:00
abstract::Subchondral bone undecalcified samples, extracted from bovine femoral heads, are subjected to a direct tensile load. The Young's modulus of each sample is determined from repeated tests within the elastic limit. In a last test, the tensile load is increased up to the specimen failure, determining the ultimate tensile ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00074-9
更新日期:2000-09-01 00:00:00
abstract::The more we learn about the intervertebral disc (IVD), the more we come to appreciate the intricacies involved in transmission of forces through the ECM to the cell, and in the biological determinants of its response to mechanical stress. This review highlights recent developments in our knowledge of IVD physiology an...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2009.09.019
更新日期:2010-01-05 00:00:00
abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.026
更新日期:2014-06-03 00:00:00
abstract::It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109843
更新日期:2020-07-17 00:00:00
abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.050
更新日期:2016-02-29 00:00:00
abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110015
更新日期:2020-10-09 00:00:00
abstract::Ligaments can be subjected to creep and fatigue damage when loaded to higher than normal stresses due to injury of a complementary joint restraint. Continuum damage mechanics (CDM) assumes that diffuse damage accumulates in a material, thereby reducing the effective cross-sectional area and leading to eventual rupture...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.04.014
更新日期:2007-01-01 00:00:00
abstract::Physical activity in children is important as it leads to healthy growth due to physiological benefits. However, a physiological benefit can be partially negated by excessive or unphysiological loads within the joints. To gain an initial understanding into this, the present study sought to compare joint loading betwee...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.01.051
更新日期:2019-04-18 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.026
更新日期:2006-01-01 00:00:00
abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90057-l
更新日期:1993-08-01 00:00:00
abstract::The purpose of this study was to gain an improved understanding of the mechanical behavior of the intervertebral disc in the presence and absence of the vertebral endplates. Mechanical behaviors of rat caudal motion segments, vertebrae and isolated disc explants under two different permeability conditions were investi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.013
更新日期:2007-01-01 00:00:00
abstract::Differences in motion patterns subserving the same movement goal can be identified qualitatively. These alternatives, which may characterize 'movement techniques' (e.g., the stoop and the squat lifting technique), may be associated with significantly different biomechanical constraints and physiological responses. Des...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.04.014
更新日期:2005-03-01 00:00:00
abstract::The effects of changing the direction of the bite force and of the mandibular joint reaction have been studied with a mathematical model assisted by a computer using the technique of linear programming. We conclude the following: In the sagittal plane the long axes of lower molars are each tilted in the direction that...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90246-6
更新日期:1987-01-01 00:00:00
abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.12.011
更新日期:2007-01-01 00:00:00
abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.017
更新日期:2009-09-18 00:00:00