Biomechanical evaluation of walking and cycling in children.

Abstract:

:Physical activity in children is important as it leads to healthy growth due to physiological benefits. However, a physiological benefit can be partially negated by excessive or unphysiological loads within the joints. To gain an initial understanding into this, the present study sought to compare joint loading between walking and cycling in children. With institutional ethical approval, 14 pre-pubertal children aged 8-12 walked on an instrumented treadmill and cycled on a stationary ergometer. Two methods were used to match physiological load. Cardiovascular loads between walking and cycling were matched using heart rate. Metabolic load was normalised by matching estimates of oxygen consumption. Joint reaction forces during cycling and walking as well as joint moments were derived using inverse dynamics. Peak compressive forces were greater on the knees and ankles during walking than during cycling. Peak shear peak forces at the knee and ankle were also significantly larger during walking than during cycling, independent of how physiological load was normalised. For both cycling conditions, ankle moments were significantly smaller during cycling than walking. No differences were found for knee moments. At equivalent physiological intensities, cycling results in less joint loading than walking. It can be speculated that for certain populations and under certain conditions cycling might be a more suitable mode of exercise than weight bearing activities to achieve a given metabolic load.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Greca JPA,Ryan J,Baltzopoulos V,Korff T

doi

10.1016/j.jbiomech.2019.01.051

subject

Has Abstract

pub_date

2019-04-18 00:00:00

pages

13-18

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30108-3

journal_volume

87

pub_type

杂志文章
  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

    abstract::The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00103-9

    authors: Dunning CE,Duck TR,King GJ,Johnson JA

    更新日期:2003-08-01 00:00:00

  • A thermodynamically consistent constitutive equation for the elastic force-length relation of soft biological materials.

    abstract::Starting from the laws of thermodynamics of reversible processes, a temperature-dependent constitutive equation is derived for the elastic force-length relation of soft biological tissues. These tissues are composed of a network of fibres (mainly collagen). The equation is based on a model which uses a simplified two-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90222-4

    authors: Maes M,Vanhuyse VJ,Decraemer WF,Raman ER

    更新日期:1989-01-01 00:00:00

  • Residual force enhancement during submaximal and maximal effort contractions of the plantar flexors across knee angle.

    abstract::Following active muscle lengthening, steady-state isometric force is elevated compared with an isometric contraction without prior lengthening for the same muscle length and activation level. This property of muscle contraction is known as residual force enhancement (RFE). Here, we aimed to determine whether neural fa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.019

    authors: Dalton BH,Contento VS,Power GA

    更新日期:2018-09-10 00:00:00

  • Kinetic analysis of the center of gravity of the human body in normal and pathological gaits.

    abstract::The kinetics of the body's center of gravity during level walking were analyzed in 50 normal subjects and 47 patients. The three-dimensional displacements of the center of gravity were computed by the integration of force plate data. The energy levels and the power requirements of the center of gravity were also calcu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90328-9

    authors: Iida H,Yamamuro T

    更新日期:1987-01-01 00:00:00

  • Explicit finite element modeling of total knee replacement mechanics.

    abstract::Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Efficient computer models present an effective way of evaluating these characteristics. Predicted contact stress and area due to articulations at the tibio-femoral and patello-femoral interfaces indicate potenti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.046

    authors: Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2005-02-01 00:00:00

  • Learning new gait patterns: Exploratory muscle activity during motor learning is not predicted by motor modules.

    abstract::The motor module hypothesis in motor control proposes that the nervous system can simplify the problem of controlling a large number of muscles in human movement by grouping muscles into a smaller number of modules. Here, we tested one prediction of the modular organization hypothesis by examining whether there is pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.006

    authors: Ranganathan R,Krishnan C,Dhaher YY,Rymer WZ

    更新日期:2016-03-21 00:00:00

  • Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

    abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.003

    authors: Nawayseh N,Hamdan S

    更新日期:2019-01-03 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • Wall shear stress distribution in the human carotid siphon during pulsatile flow.

    abstract::Wall shear stress distribution in the carotid siphon, which is a multiple curved segment of the internal carotid artery, is investigated numerically under physiological flow conditions. The computer simulation of flow through the model segment is based on the time-dependent, three-dimensional Navier-Stokes equations, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90203-5

    authors: Perktold K,Florian H,Hilbert D,Peter R

    更新日期:1988-01-01 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Effect of non-Newtonian fluid properties on bovine sperm motility.

    abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.005

    authors: Hyakutake T,Suzuki H,Yamamoto S

    更新日期:2015-09-18 00:00:00

  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • Biomechanical benefits of the Onion-Skin motor unit control scheme.

    abstract::Muscle force is modulated by varying the number of active motor units and their firing rates. For the past five decades, the notion that the magnitude of the firing rates is directly related to motor unit size and recruitment threshold has been widely accepted. This construct, here named the After-hyperpolarization sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.003

    authors: De Luca CJ,Contessa P

    更新日期:2015-01-21 00:00:00

  • A numerical simulation of mechanical heart valve closure fluid dynamics.

    abstract::A computational fluid dynamics model for the analysis of the bileaflet mechanical heart valve closure process is presented. The objective of the study is to demonstrate the ability of the numerical model to simulate the leaflet motion during the closing phase in order to investigate the closure fluid dynamics and to e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00056-8

    authors: Lai YG,Chandran KB,Lemmon J

    更新日期:2002-07-01 00:00:00

  • Insufficient accuracy of the ultrasound-based determination of Achilles tendon cross-sectional area.

    abstract::The accurate assessment of the Achilles tendon cross-sectional area (CSA) is a crucial prerequisite to investigate tendon adaptation and to calculate the tendon Young׳s modulus. Besides magnetic resonance imaging (MRI), ultrasonography emerged as an alternative imaging technique. The purpose of the present study was t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.002

    authors: Bohm S,Mersmann F,Schroll A,Mäkitalo N,Arampatzis A

    更新日期:2016-09-06 00:00:00

  • Upper body accelerations during planned gait termination in young and older women.

    abstract::Transitory tasks, such as gait termination, involve interactions between neural and biomechanical factors that challenge postural stability and head stabilization patterns in older adults. The aim of the study was to compare upper body patterns of acceleration during planned gait termination at different speeds betwee...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.019

    authors: Rum L,Laudani L,Macaluso A,Vannozzi G

    更新日期:2017-12-08 00:00:00

  • Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling.

    abstract::The compressive properties of skeletal muscle are important in impact biomechanics, rehabilitation engineering and surgical simulation. However, the mechanical behaviour of muscle tissue in compression remains poorly characterised. In this paper, the time-dependent properties of passive skeletal muscle were investigat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.007

    authors: Van Loocke M,Lyons CG,Simms CK

    更新日期:2008-01-01 00:00:00

  • The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone.

    abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.006

    authors: Russell N,Rives A,Bertollo N,Pelletier MH,Walsh WR

    更新日期:2013-06-21 00:00:00

  • Squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage with the superficial zone worn out.

    abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00109-3

    authors: Hlavácek M

    更新日期:2000-11-01 00:00:00

  • The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

    abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.03.014

    authors: Steinberg EL,Blumberg N,Dekel S

    更新日期:2005-01-01 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Muscle activity reduces soft-tissue resonance at heel-strike during walking.

    abstract::Muscle activity has previously been suggested to minimize soft-tissue resonance which occurs at heel-strike during walking and running. If this concept were true then the greatest vibration damping would occur when the input force was closest to the resonant frequency of the soft-tissues at heel-strike. However, this ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(03)00216-1

    authors: Wakeling JM,Liphardt AM,Nigg BM

    更新日期:2003-12-01 00:00:00

  • Runners adjust leg stiffness for their first step on a new running surface.

    abstract::Human runners adjust the stiffness of their stance leg to accommodate surface stiffness during steady state running. This adjustment allows runners to maintain similar center of mass movement (e.g., ground contact time and stride frequency) regardless of surface stiffness. When runners encounter abrupt transitions in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(99)00078-0

    authors: Ferris DP,Liang K,Farley CT

    更新日期:1999-08-01 00:00:00

  • Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment.

    abstract::The drop vertical jump (DVJ) task is commonly used to assess biomechanical performance measures that are associated with ACL injury risk in athletes. Previous investigations have solely assessed the first landing phase. We examined the first and second landings of a DVJ for differences in the magnitude of vertical gro...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.02.024

    authors: Bates NA,Ford KR,Myer GD,Hewett TE

    更新日期:2013-04-26 00:00:00

  • Mechanical properties of the tibia from chickens with idiopathic scoliosis.

    abstract::The tibia from six-week old chickens that develop idiopathic scoliosis were studied with stress relaxation experiments and torsional strength testing. Most parameters observed did not show any significant differences between tibias obtained from chickens with scoliosis and tibias from the control birds; however, the r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90046-5

    authors: Riggins RS,Lewis DA,Benson DR,McCarrey JR,Franti CE

    更新日期:1983-01-01 00:00:00

  • Growth and surface folding of esophageal mucosa: a biomechanical model.

    abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.007

    authors: Li B,Cao YP,Feng XQ

    更新日期:2011-01-04 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Ambulatory measurement of the knee adduction moment in patients with osteoarthritis of the knee.

    abstract::High knee joint-loading increases the risk and progression of knee osteoarthritis (OA). Mechanical loading on the knee is reflected in the external knee adduction moment (KAdM) that can be measured during gait with laboratory-based measurement systems. However, clinical application of these systems is limited. Ambulat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.09.030

    authors: van den Noort JJ,van der Esch M,Steultjens MP,Dekker J,Schepers MH,Veltink PH,Harlaar J

    更新日期:2013-01-04 00:00:00