Abstract:
:High knee joint-loading increases the risk and progression of knee osteoarthritis (OA). Mechanical loading on the knee is reflected in the external knee adduction moment (KAdM) that can be measured during gait with laboratory-based measurement systems. However, clinical application of these systems is limited. Ambulatory movement analysis systems, including instrumented force shoes (IFS) and an inertial and magnetic measurement system (IMMS), could potentially be used to determine the KAdM in a laboratory-free setting. Promising results have been reported concerning the use of the IFS in KAdM measurements; however its application in combination with IMMS has not been studied. The objective of this study was to compare the KAdM measured with an ambulatory movement analysis system with a laboratory-based system in patients with knee OA. Gait analyses of 14 knee OA patients were performed in a gait laboratory. The KAdM was concurrently determined with two the systems: (i) Ambulatory: IFS and IMMS in combination with a linked-segment model (to obtain joint positions); (ii) Laboratory: force plate and optoelectronic marker system. Mean differences in KAdM between the ambulatory and laboratory system were not significant (maximal difference 0.20%BW*H in late stance, i.e. 5.6% of KAdM range, P>0.05) and below clinical relevant and hypothesized differences, showing no systematic differences at group level. Absolute differences were on average 24% of KAdM range, i.e. 0.83%BW*H, particularly in early and late stance. To achieve greater accuracy for clinical use, estimation of joint position via a more advanced calibrated linked-segment model should be investigated.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
van den Noort JJ,van der Esch M,Steultjens MP,Dekker J,Schepers MH,Veltink PH,Harlaar Jdoi
10.1016/j.jbiomech.2012.09.030subject
Has Abstractpub_date
2013-01-04 00:00:00pages
43-9issue
1eissn
0021-9290issn
1873-2380pii
S0021-9290(12)00581-7journal_volume
46pub_type
杂志文章abstract::Tissue scaffolds are typically designed and fabricated to match native bone properties. However, it is unclear if this would lead to the best tissue ingrowth outcome within the scaffold as neo-tissue keeps changing the stiffness of entire construct. This paper presents a numerical method to address this issue for desi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.020
更新日期:2010-06-18 00:00:00
abstract::Arterial stiffening occurs with age and is associated with lack of exercise. Notably both age and lack of exercise are major cardiovascular risk factors. While it is well established that bulk arterial stiffness increases with age, more recent data suggest that the intima, the innermost arterial layer, also stiffens d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.03.016
更新日期:2016-06-14 00:00:00
abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.012
更新日期:2014-05-07 00:00:00
abstract::The purpose of this study was to investigate the effect of thickness, cross-sectional area and stiffness of intrinsic foot muscles on performance in single-leg stance balance tasks in healthy sedentary young females. This study included a total of 40 healthy sedentary young females between the ages of 19 and 35 years....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109530
更新日期:2020-01-23 00:00:00
abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.011
更新日期:2010-03-22 00:00:00
abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.033
更新日期:2010-04-19 00:00:00
abstract::Progression and rupture of atherosclerotic plaques in coronary and carotid arteries are the key processes underlying myocardial infarctions and strokes. Biomechanical stress analyses to compute mechanical stresses in a plaque can potentially be used to assess plaque vulnerability. The stress analyses strongly rely on ...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.01.019
更新日期:2014-03-03 00:00:00
abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90365-l
更新日期:1993-03-01 00:00:00
abstract::Although arterial blood flow is physiologically non-periodic under resting conditions, periodic flow assumption has been widely adopted in most hemodynamic studies. So far, it remains unclear how the non-periodicity of blood flow would influence local hemodynamic parameters, especially wall shear stress (WSS) that ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109617
更新日期:2020-03-05 00:00:00
abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.004
更新日期:2010-05-07 00:00:00
abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.12.008
更新日期:2010-04-19 00:00:00
abstract::A two-dimensional, five-muscle model was used to determine the degree of precision required for accurate calculation of temporomandibular joint force magnitude and direction. The sensitivity of the calculations to each variable were assessed by incrementing each variable through its presumed biological range and were ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90206-6
更新日期:1989-01-01 00:00:00
abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.07.030
更新日期:2005-08-01 00:00:00
abstract::Human responses are critical to understanding injury biomechanics in blunt ballistic impacts, which are defined as 20-200 g projectiles impacting at 20-250 m/s. 13 human cadavers were exposed to three distinct ballistic impacts of the chest to determine force-time, deflection-time and force-deflection responses. Compa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00238-0
更新日期:2004-01-01 00:00:00
abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.09.014
更新日期:2008-01-01 00:00:00
abstract::Lymphatic valves facilitate the lymphatic system's role in maintaining fluid homeostasis. Malformed valves are found in several forms of primary lymphœdema, resulting in incurable swelling of the tissues and immune dysfunction. Their experimental study is complicated by their small size and operation in low pressure a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.040
更新日期:2017-11-07 00:00:00
abstract::A method for measuring three-dimensional kinematics that incorporates the direct cross-registration of experimental kinematics with anatomic geometry from Computed Tomography (CT) data has been developed. Plexiglas registration blocks were attached to the bones of interest and the specimen was CT scanned. Computer mod...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00195-0
更新日期:2001-03-01 00:00:00
abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.04.016
更新日期:2013-06-21 00:00:00
abstract::Individual differences in bone mass distribution at the proximal femur may be determined by daily weight-bearing physical activity (PA) since bone self-adapts according to the mechanical loads that is submitted. The aim of this study was to analyse computationally the effect of different weight-bearing PA types in the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.06.031
更新日期:2013-09-03 00:00:00
abstract::The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement erro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110184
更新日期:2020-12-24 00:00:00
abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.08.008
更新日期:2016-10-03 00:00:00
abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.03.001
更新日期:2007-01-01 00:00:00
abstract::Intramuscular pressure correlates strongly with muscle tension and is a promising tool for quantifying individual muscle force. However, clinical application is impeded by measurement variability that is not fully understood. Previous studies point to regional differences in IMP, specifically increasing pressure with ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.09.002
更新日期:2016-10-03 00:00:00
abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00129-r
更新日期:1995-07-01 00:00:00
abstract::We propose a numerical model of hemodynamics arising from malaria infection. This model is based on a particle method, where all the components of blood are represented by the finite number of particles. A two-dimensional spring network of membrane particles is employed for expressing the deformation of malaria infect...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.01.011
更新日期:2010-05-07 00:00:00
abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...
journal_title:Journal of biomechanics
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.jbiomech.2019.109579
更新日期:2020-02-13 00:00:00
abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.007
更新日期:2006-01-01 00:00:00
abstract::Body weight support (BWS) systems are a common tool used in gait rehabilitation. BWS systems may alter the requirements for an individual to actively stabilize by 1) providing lateral restoring forces that reduce the requirements for the nervous system to actively stabilize and 2) decreasing the stabilizing gravitatio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.026
更新日期:2016-09-06 00:00:00
abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00191-8
更新日期:2000-03-01 00:00:00
abstract::The purpose of this study was to compare three camera calibration approaches applied to underwater applications: (1) static control points with nonlinear DLT; (2) moving wand with nonlinear camera model and bundle adjustment; (3) moving plate with nonlinear camera model. The DVideo kinematic analysis system was used f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.01.004
更新日期:2012-04-05 00:00:00