The effect of simulated marker misplacement on the interpretation of inter-limb differences during a change of direction task.

Abstract:

:The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement error effects the interpretation of biomechanical asymmetries throughout post ACLR rehabilitation. The aim of this investigation was to determine the effect of random marker placement variation on the interpretation of inter-limb differences during a change of direction (CoD) task. Forty-seven participants 9 months post-ACLR and fifty uninjured controls completed a 90° CoD task on both limbs. Inter-limb differences in kinematic and kinetic metrics during the CoD stance phase were calculated for both groups using the Vicon Plug-in Gait model, and ACLR subjects were classified as having 'normal' or 'abnormal' inter-limb differences relative to the control group. Simulated random marker displacements based on published marker placement error ranges were then repeatedly applied to the lateral thigh, femoral epicondyle and tibia markers. ACLR inter-limb differences were recalculated each time, allowing the estimation of 95% confidence intervals and minimal identifiable between-session changes. ACLR subjects were also reclassified relative to the control group after each simulation and the percentage of participants to change classification was calculated. Marker displacements caused large deviations in inter-limb difference measures in several variables including hip rotation angle, knee abduction angle and knee abduction moment, thus limiting the ability to identify participants with large inter-limb differences relative to a control group. These findings highlight the challenges in using marker-based biomechanical models to conduct objective assessments of inter-limb differences during CoD tasks.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

McFadden C,Daniels K,Strike S

doi

10.1016/j.jbiomech.2020.110184

subject

Has Abstract

pub_date

2020-12-24 00:00:00

pages

110184

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30608-4

journal_volume

116

pub_type

杂志文章
  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Mechanics of toe and heel landing in stepping down in ongoing gait.

    abstract::When stepping down from a height difference in ongoing gait, subjects are known to use a heel landing at small height differences and switch to toe landing for larger height differences. We hypothesized that in toe landing, the leading leg can perform more negative work, to control the momentum gained during the desce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.022

    authors: van Dieën JH,Spanjaard M,Könemann R,Bron L,Pijnappels M

    更新日期:2008-08-07 00:00:00

  • The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

    abstract::Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.021

    authors: Defrate LE,van der Ven A,Boyer PJ,Gill TJ,Li G

    更新日期:2006-01-01 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • Vertebroplasty reduces progressive ׳creep' deformity of fractured vertebrae.

    abstract::Elderly vertebrae frequently develop an "anterior wedge" deformity as a result of fracture and creep mechanisms. Injecting cement into a damaged vertebral body (vertebroplasty) is known to help restore its shape and stiffness. We now hypothesise that vertebroplasty is also effective in reducing subsequent creep deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.006

    authors: Luo J,Pollintine P,Annesley-Williams DJ,Dolan P,Adams MA

    更新日期:2016-04-11 00:00:00

  • Reproducibility of energy parameters in the pole vault.

    abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.027

    authors: Schade F,Arampatzis A,Brüggemann GP

    更新日期:2006-01-01 00:00:00

  • Experimental measurement and quantification of frictional contact between biological surfaces experiencing large deformation and slip.

    abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.006

    authors: Gratz KR,Sah RL

    更新日期:2008-01-01 00:00:00

  • Diffusion of water in skeletal muscle tissue is not influenced by compression in a rat model of deep tissue injury.

    abstract::Sustained mechanical loading of skeletal muscle may result in the development of a severe type of pressure ulcer, referred to as deep tissue injury. Recently it was shown that the diffusion of large molecules (10-150kDa) is impaired during deformation of tissue-engineered skeletal muscle, suggesting a role for impaire...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.043

    authors: van Nierop BJ,Stekelenburg A,Loerakker S,Oomens CW,Bader D,Strijkers GJ,Nicolay K

    更新日期:2010-02-10 00:00:00

  • Residual force enhancement during submaximal and maximal effort contractions of the plantar flexors across knee angle.

    abstract::Following active muscle lengthening, steady-state isometric force is elevated compared with an isometric contraction without prior lengthening for the same muscle length and activation level. This property of muscle contraction is known as residual force enhancement (RFE). Here, we aimed to determine whether neural fa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.019

    authors: Dalton BH,Contento VS,Power GA

    更新日期:2018-09-10 00:00:00

  • A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator.

    abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00034-7

    authors: Bigsby RJ,Auger DD,Jin ZM,Dowson D,Hardaker CS,Fisher J

    更新日期:1998-04-01 00:00:00

  • Confocal-based cell-specific finite element modeling extended to study variable cell shapes and intracellular structures: the example of the adipocyte.

    abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.012

    authors: Or-Tzadikario S,Gefen A

    更新日期:2011-02-03 00:00:00

  • Untangling biomechanical differences in perturbation-induced stepping strategies for lateral balance stability in older individuals.

    abstract::When recovering balance from a lateral perturbation, younger adults tend to stabilize balance with a single lateral sidestep while older adults often take multistep responses. Using multiple steps to recover balance is consistently associated with increased fall risk, altered body center of mass (CoM) control and inst...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110161

    authors: Borrelli J,Creath R,Gray VL,Rogers MW

    更新日期:2021-01-04 00:00:00

  • The effect of swimming activity on bone architecture in growing rats.

    abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90068-7

    authors: Simkin A,Leichter I,Swissa A,Samueloff S

    更新日期:1989-01-01 00:00:00

  • Comparison of three local frame definitions for the kinematic analysis of the fingers and the wrist.

    abstract::Because the hand is a complex poly-articular limb, numerous methods have been proposed to investigate its kinematics therefore complicating the comparison between studies and the methodological choices. With the objective of overcoming such issues, the present study compared the effect of three local frame definitions...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.025

    authors: Goislard de Monsabert B,Visser JM,Vigouroux L,Van der Helm FC,Veeger HE

    更新日期:2014-08-22 00:00:00

  • Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

    abstract::The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00103-9

    authors: Dunning CE,Duck TR,King GJ,Johnson JA

    更新日期:2003-08-01 00:00:00

  • In vivo contact areas of the knee in patients with patellar subluxation.

    abstract:OBJECTIVE:Ex vivo studies have suggested that cartilage contact areas and pressure are of high clinical relevance in the etiology of osteoarthritis in patients with patellar subluxation. The aims of this study were therefore to validate in vivo measurements of contact areas with 3D open magnetic resonance imaging (MRI)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.008

    authors: Hinterwimmer S,Gotthardt M,von Eisenhart-Rothe R,Sauerland S,Siebert M,Vogl T,Eckstein F,Graichen H

    更新日期:2005-10-01 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • A general approach for modelling and mathematical investigation of the human upper limb.

    abstract::This paper is an attempt to systematize and solve the problems connected with biomechanical modelling and mathematical investigation of the upper limb, when all muscles acting on the shoulder, elbow and wrist joint are included. The basic problem is the assumption of a hypothesis for the unit vectors, collinear with m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90226-q

    authors: Raikova R

    更新日期:1992-08-01 00:00:00

  • Hemodynamic insight into overlapping bare-metal stents strategy in the treatment of aortic aneurysm.

    abstract::Clinical trials have shown overlapping bare-metal stents provoke effective thrombus clot within the aneurysm sac and shrinkage of the aneurysm by directly regulating the hemodynamics. To gain insight into the hemodynamic mechanism of the technique, three cases of simplified thoracic aortic aneurysm models (with no ste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.028

    authors: Zhang P,Liu X,Sun A,Fan Y,Deng X

    更新日期:2015-07-16 00:00:00

  • Validation of optimization models that estimate the forces exerted by synergistic muscles.

    abstract::The purpose of this study was to validate the mathematical predictions of individual muscle forces obtained using optimization models. Mathematical muscle force predictions were made using linear and nonlinear optimization models proposed in the literature. Actual muscle forces were measured experimentally from soleus...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90375-w

    authors: Herzog W,Leonard TR

    更新日期:1991-01-01 00:00:00

  • Mass, center of mass, and moment of inertia estimates for infant limb segments.

    abstract::To quantify limb dynamics, accurate estimates are needed of anthropometric inertia parameters (mass, center-of-mass location, and moments of inertia). These estimates, however, are not available for human infants; therefore, the movement dynamics of infants have not been studied extensively. Here, regression equations...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90271-2

    authors: Schneider K,Zernicke RF

    更新日期:1992-02-01 00:00:00

  • Collagen fibril D-period may change as a function of strain and location in ligament.

    abstract::The purpose of this study was to determine if the characteristic banding pattern (D-period) of collagen fibrils from rabbit medial collateral ligaments changes as a function of gross ligament strain and, if so, whether the changes are location dependent (insertion versus midsubstance). Femur-medial collateral ligament...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00150-0

    authors: Kukreti U,Belkoff SM

    更新日期:2000-12-01 00:00:00

  • In situ fibril stretch and sliding is location-dependent in mouse supraspinatus tendons.

    abstract::Tendons are able to transmit high loads efficiently due to their finely optimized hierarchical collagen structure. Two mechanisms by which tendons respond to load are collagen fibril sliding and deformation (stretch). Although many studies have demonstrated that regional variations in tendon structure, composition, an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.029

    authors: Connizzo BK,Sarver JJ,Han L,Soslowsky LJ

    更新日期:2014-12-18 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • A stereophotogrammetric method for determining in situ contact areas in diarthrodial joints, and a comparison with other methods.

    abstract::Determination of contact areas in diarthrodial joints is necessary for understanding the state of stress within the articular cartilage layers and the supporting bony structures. The present study describes the use of a stereophotogrammetry (SPG) system [Huiskes et al., J. Biomechanics 18, 559-570 (1985) and Ateshian ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90038-8

    authors: Ateshian GA,Kwak SD,Soslowsky LJ,Mow VC

    更新日期:1994-01-01 00:00:00

  • The use of a single inertial sensor to estimate 3-dimensional ground reaction force during accelerative running tasks.

    abstract::The purpose of this investigation was to determine the feasibility of using a single inertial measurement unit (IMU) placed on the sacrum to estimate 3-dimensional ground reaction force (F) during linear acceleration and change of direction tasks. Force plate measurements of F and estimates from the proposed IMU metho...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.035

    authors: Gurchiek RD,McGinnis RS,Needle AR,McBride JM,van Werkhoven H

    更新日期:2017-08-16 00:00:00

  • Validation of shear wave elastography in skeletal muscle.

    abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.033

    authors: Eby SF,Song P,Chen S,Chen Q,Greenleaf JF,An KN

    更新日期:2013-09-27 00:00:00

  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • Incorporation of vasculature in a head injury model lowers local mechanical strains in dynamic impact.

    abstract::Cerebral vasculature is several orders of magnitude stiffer than the brain tissue. However, only a handful of studies have investigated its potential stiffening effect on dynamic brain strains; yet, they report contradictory findings. Here, we reanalyze the cerebrovascular stiffening effect by incorporating vasculatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109732

    authors: Zhao W,Ji S

    更新日期:2020-05-07 00:00:00

  • Mechanical characterization of stomach tissue under uniaxial tensile action.

    abstract::In this article, the tensile properties of gastric wall were investigated by using biomechanical test and theoretical analysis. The samples of porcine stomach strips from smaller and greater curvature of the stomach were cut in longitudinal and circumferential direction, respectively. The loading-unloading, stress rel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.048

    authors: Jia ZG,Li W,Zhou ZR

    更新日期:2015-02-26 00:00:00