Muscle activity reduces soft-tissue resonance at heel-strike during walking.

Abstract:

:Muscle activity has previously been suggested to minimize soft-tissue resonance which occurs at heel-strike during walking and running. If this concept were true then the greatest vibration damping would occur when the input force was closest to the resonant frequency of the soft-tissues at heel-strike. However, this idea has not been tested. The purpose of this study was to test whether muscle activity in the lower extremity is used to damp soft-tissue resonance which occurs at heel-strike during walking. Hard and soft shoe conditions were tested in a randomized block design. Ground reaction forces, soft-tissue accelerations and myoelectric activity were measured during walking for 40 subjects. Soft-tissue mass was estimated from anthropologic measurements, allowing inertial forces in the soft-tissues to be calculated. The force transfer from the ground to the tissues was compared with changes in the muscle activity. The soft condition resulted in relative frequencies (input/tissue) to be closer to resonance for the main soft-tissue groups. However, no increase in force transmission was observed. Therefore, the vibration damping in the tissues must have increased. This increase concurred with increases in the muscle activity for the biceps femoris and lateral gastrocnemius. The evidence supports the proposal that muscle activity damps soft-tissue resonance at heel-strike. Muscles generate forces which act across the joints and, therefore, shoe design may be used to modify muscle activity and thus joint loading during walking and running.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Wakeling JM,Liphardt AM,Nigg BM

doi

10.1016/s0021-9290(03)00216-1

keywords:

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

1761-9

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021929003002161

journal_volume

36

pub_type

临床试验,杂志文章,随机对照试验
  • Exercise-induced hyperthermia as a possible mechanism for tendon degeneration.

    abstract::Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90262-3

    authors: Wilson AM,Goodship AE

    更新日期:1994-07-01 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • Focal cryogen insults for inducing segmental osteonecrosis: computational and experimental assessments of thermal fields.

    abstract::Orthopaedic management of femoral head osteonecrosis is a common clinical problem for which there presently is no good solution. Current animal models are inappropriate to study potential new solutions, since it has been difficult to replicate the natural history of structural collapse seen in the human disorder. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00154-4

    authors: Reed KL,Brown TD,Conzemius MG

    更新日期:2003-09-01 00:00:00

  • A general approach for modelling and mathematical investigation of the human upper limb.

    abstract::This paper is an attempt to systematize and solve the problems connected with biomechanical modelling and mathematical investigation of the upper limb, when all muscles acting on the shoulder, elbow and wrist joint are included. The basic problem is the assumption of a hypothesis for the unit vectors, collinear with m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90226-q

    authors: Raikova R

    更新日期:1992-08-01 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • Velocity profiles in annular perfusion chamber measured by laser-Doppler velocimetry.

    abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90081-2

    authors: Aarts PA,van Broek JA,Kuiken GD,Sixma JJ,Heethaar RM

    更新日期:1984-01-01 00:00:00

  • A three-dimensional mathematical model of the thoracolumbar fascia and an estimate of its biomechanical effect.

    abstract::The thoracolumbar fascia (TLF) provides a means of attachment to the lumbar spine for several muscles including the transverse abdominis, and parts of the latissimus dorsi and internal oblique muscles. Previous biomechanical models of the lumbar spine either tend to omit the TLF on the assumption that its contribution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.022

    authors: Gatton ML,Pearcy MJ,Pettet GJ,Evans JH

    更新日期:2010-10-19 00:00:00

  • Pain catastrophizing moderates changes in spinal control in response to noxiously induced low back pain.

    abstract::It is generally accepted that spine control and stability are relevant for the prevention and rehabilitation of low back pain (LBP). However, there are conflicting results in the literature in regards to how these variables are modified in the presence of LBP. The aims of the present work were twofold: (1) to use noxi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.010

    authors: Ross GB,Sheahan PJ,Mahoney B,Gurd BJ,Hodges PW,Graham RB

    更新日期:2017-06-14 00:00:00

  • Mechanical stretch inhibits mesenchymal stem cell adipogenic differentiation through TGFβ1/Smad2 signaling.

    abstract::Mesenchymal stem cells (MSCs) are the common precursors of several functionally disparate cell lineages. A plethora of chemical and physical stimuli contribute to lineage decisions and guidance, including mechanical stretch concomitant with physical movement. Here, we examined how stretch regulates MSC differentiation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.013

    authors: Li R,Liang L,Dou Y,Huang Z,Mo H,Wang Y,Yu B

    更新日期:2015-10-15 00:00:00

  • Biomechanical benefits of the Onion-Skin motor unit control scheme.

    abstract::Muscle force is modulated by varying the number of active motor units and their firing rates. For the past five decades, the notion that the magnitude of the firing rates is directly related to motor unit size and recruitment threshold has been widely accepted. This construct, here named the After-hyperpolarization sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.003

    authors: De Luca CJ,Contessa P

    更新日期:2015-01-21 00:00:00

  • Composition of the cement line and its possible mechanical role as a local interface in human compact bone.

    abstract::Human compact bone may be viewed as a fiber reinforced composite material in which the secondary osteons act as the fiber reinforcements. The cement line, which is the interface between the 'fibers' (osteons) and extraosteonal bone matrix, may impart important mechanical properties to compact bone. The nature of these...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90132-7

    authors: Burr DB,Schaffler MB,Frederickson RG

    更新日期:1988-01-01 00:00:00

  • Measurement of local diffusion and composition in degraded articular cartilage reveals the unique role of surface structure in controlling macromolecular transport.

    abstract::Developing effective therapeutics for osteoarthritis (OA) necessitates that such molecules can reach and target chondrocytes within articular cartilage. However, predicting how well very large therapeutic molecules diffuse through cartilage is often difficult, and the relationship between local transport mechanics for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.019

    authors: DiDomenico CD,Kaghazchi A,Bonassar LJ

    更新日期:2019-01-03 00:00:00

  • Quantitative associations between osteocyte density and biomechanics, microcrack and microstructure in OVX rats vertebral trabeculae.

    abstract::Osteocytes actively regulate bone modeling and remodeling, direct skeletal mineralization, and regulate calcium/phosphate homeostasis and extracellular matrix metabolism; yet the specific role of osteocytes in maintaining bone structural integrity and strength is unknown. Studies have shown that the density of osteocy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.017

    authors: Ma YL,Dai RC,Sheng ZF,Jin Y,Zhang YH,Fang LN,Fan HJ,Liao EY

    更新日期:2008-01-01 00:00:00

  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • Oxidized low-density lipoprotein (Ox-LDL) impacts on erythrocyte viscoelasticity and its molecular mechanism.

    abstract::The oxidized low-density lipoprotein (Ox-LDL) plays an important role in atherosclerosis, yet it remains unclear if it damages circulating erythrocytes. In this study, erythrocyte deformability and its membrane proteins after Ox-LDL incubations are investigated by micropipette aspiration, thiol radical measurement, an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.026

    authors: Wang X,Yang L,Liu Y,Gao W,Peng W,Sung KL,Sung LA

    更新日期:2009-10-16 00:00:00

  • Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

    abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110085

    authors: Namiranian B,Jerban S,Ma Y,Dorthe EW,Masoud-Afsahi A,Wong J,Wei Z,Chen Y,D'Lima D,Chang EY,Du J

    更新日期:2020-12-02 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Explicit calibration method and specific device designed for stereoradiography.

    abstract::The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00016-2

    authors: Dumas R,Mitton D,Laporte S,Dubousset J,Steib JP,Lavaste F,Skalli W

    更新日期:2003-06-01 00:00:00

  • Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion.

    abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00083-6

    authors: Prilutsky BI,Petrova LN,Raitsin LM

    更新日期:1996-04-01 00:00:00

  • Influence of shoes and heel strike on the loading of the hip joint.

    abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00129-r

    authors: Bergmann G,Kniggendorf H,Graichen F,Rohlmann A

    更新日期:1995-07-01 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging.

    abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.008

    authors: Souron R,Bordat F,Farabet A,Belli A,Feasson L,Nordez A,Lapole T

    更新日期:2016-10-03 00:00:00

  • Electrical conductivity and ion diffusion in porcine meniscus: effects of strain, anisotropy, and tissue region.

    abstract::The purpose of the present study was to investigate the effects of mechanical strain, anisotropy, and tissue region on electrical conductivity and ion diffusivity in meniscus fibrocartilage. A one-dimensional, 4-wire conductivity experiment was employed to measure the electrical conductivity in porcine meniscus tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.011

    authors: Kleinhans KL,McMahan JB,Jackson AR

    更新日期:2016-09-06 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00