The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

Abstract:

:The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel alloy, consists of a nail, a peg and an anti-rotation pin. Upon positioning, the nail and peg are expanded to their maximal diameter. The current biomechanical study investigated: nail bending strength and stiffness, fatigue properties and hip peg strength. A cadaveric study that determined the effect of the expandable peg on the femoral head included subsidence testing, pull and torsion testing and intra-osseous pressure (IOP) measurements before and after expansion. Biomechanical properties of the new nail met ASTM F384 guideline requirements. The cadaver study yielded equivalent results for the pullout test between the peg and the hip screw, but found the peg superior in the torsion strength test. IOP during peg insertion and expansion was substantially lower than the threshold pressure that causes avascular necrosis. The biomechanical tests found the new system to be safe and able to provide good abutment of the nail to the bone. We conclude that the Fixion PFN system proved to be an effective proximal femur fracture fixation device.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Steinberg EL,Blumberg N,Dekel S

doi

10.1016/j.jbiomech.2004.03.014

keywords:

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

63-8

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021929004001459

journal_volume

38

pub_type

杂志文章
  • Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

    abstract::The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00103-9

    authors: Dunning CE,Duck TR,King GJ,Johnson JA

    更新日期:2003-08-01 00:00:00

  • Effects of lumbo-pelvic rhythm on trunk muscle forces and disc loads during forward flexion: A combined musculoskeletal and finite element simulation study.

    abstract::Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.009

    authors: Liu T,Khalaf K,Adeeb S,El-Rich M

    更新日期:2019-01-03 00:00:00

  • Osteonal structure better predicts tensile strength of healing bone than volume fraction.

    abstract::Refractures and secondary fractures occur after removal of internal fixation devices even when the X-rays show well-mineralized bony unions. This indicates the unreliability of bone density as the only parameter to estimate the strength of healing bone. The aim of this study was to show that the strength of healing bo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00006-4

    authors: Claes LE,Wilke HJ,Kiefer H

    更新日期:1995-11-01 00:00:00

  • Further evidence for the dynamic stability of intracranial saccular aneurysms.

    abstract::It has long been thought that intracranial saccular aneurysms enlarge and rupture because of mechanical instabilities. Recent nonlinear analyses suggest, however, that at least certain sub-classes of aneurysms do not exhibit quasi-static limit point instabilities or dynamic instabilities in response to periodic loadin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00083-6

    authors: David G,Humphrey JD

    更新日期:2003-08-01 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • Parametric and subject-specific finite element modelling of the lower cervical spine. Influence of geometrical parameters on the motion patterns.

    abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.007

    authors: Laville A,Laporte S,Skalli W

    更新日期:2009-07-22 00:00:00

  • Prior storage conditions and loading rate affect the in vitro fracture response of spinal segments under impact loading.

    abstract::Traumatic injuries of the spine are mostly the consequence of rapid overload e.g. impact loading. In vitro investigations on this topic usually encompass biomechanical testing using frozen/thawed specimens and employ quasi-static loading conditions. It is generally accepted that a freezing/thawing cycle does not alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.011

    authors: Dudli S,Haschtmann D,Ferguson SJ

    更新日期:2011-09-02 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • Estimation of unmeasured ground reaction force data based on the oscillatory characteristics of the center of mass during human walking.

    abstract::To enhance the wearability of portable motion-monitoring devices, the size and number of sensors are minimized, but at the expense of quality and quantity of data collected. For example, owing to the size and weight of low-frequency force transducers, most currently available wearable gait measurement systems provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.046

    authors: Ryu HX,Park S

    更新日期:2018-04-11 00:00:00

  • Quantifying thumb opposition kinematics using dynamic computed tomography.

    abstract::Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.008

    authors: Kerkhof FD,Brugman E,D'Agostino P,Dourthe B,van Lenthe GH,Stockmans F,Jonkers I,Vereecke EE

    更新日期:2016-06-14 00:00:00

  • Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing.

    abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.026

    authors: Knothe UR,Dolejs S,Matthew Miller R,Knothe Tate ML

    更新日期:2010-10-19 00:00:00

  • Hydro-resistive measurement of dynamic lifting strength.

    abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00155-8

    authors: Pinder AD,Grieve DW

    更新日期:1997-04-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants.

    abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.036

    authors: Massaroni C,Piaia Silvatti A,Levai IK,Dickinson J,Winter S,Schena E,Silvestri S

    更新日期:2018-07-25 00:00:00

  • Ventilation inhomogeneity: alveolar mechanics and gas distribution.

    abstract::The effects of regional lung differences in alveolar mechanics on the transpulmonary pressure-volume (Ptp-V) relationship and the single-breath washout (SBW) of nitrogen were investigated by mathematical modeling and postmorten human lung experiments. Regional nonuniformity in alveolar collapse and re-opening were ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90100-8

    authors: Salmon RB,Saidel GM,Primiano FP Jr,Niewoehner DE,Chester EH

    更新日期:1983-01-01 00:00:00

  • Challenges to bone formation in spinal fusion.

    abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2010.10.021

    authors: Reid JJ,Johnson JS,Wang JC

    更新日期:2011-01-11 00:00:00

  • Influence of intramuscular fiber orientation on the Achilles tendon curvature using three-dimensional finite element modeling of contracting skeletal muscle.

    abstract::Tendon curvature plays a key role in mechanical gain (amplifying the joint excursion relative to fiber length change) during joint motion, but the mechanism remains unresolved. A three-dimensional finite element (FE) model was used to investigate the influence of intramuscular fiber orientation upon the curvature patt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.014

    authors: Kinugasa R,Yamamura N,Sinha S,Takagi S

    更新日期:2016-10-03 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable.

    abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.051

    authors: Wiens C,Denton W,Schieber MN,Hartley R,Marmelat V,Myers SA,Yentes JM

    更新日期:2019-01-23 00:00:00

  • Macroscopic anisotropic bone material properties in children with severe osteogenesis imperfecta.

    abstract::Children with severe osteogenesis imperfecta (OI) typically experience numerous fractures and progressive skeletal deformities over their lifetime. Recent studies proposed finite element models to assess fracture risk and guide clinicians in determining appropriate intervention in children with OI, but lack of appropr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.003

    authors: Albert C,Jameson J,Tarima S,Smith P,Harris G

    更新日期:2017-11-07 00:00:00

  • An analytical study on the thermal effects of cryosurgery on selective cell destruction.

    abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.005

    authors: Chua KJ,Chou SK,Ho JC

    更新日期:2007-01-01 00:00:00

  • Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechano-sensitivity.

    abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.003

    authors: Khayyeri H,Checa S,Tägil M,Aspenberg P,Prendergast PJ

    更新日期:2011-04-07 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • A critical comparison of different residence time measures in aneurysms.

    abstract::Flow stagnation and residence time (RT) are important features of diseased arterial flows that influence biochemical transport processes and thrombosis. RT calculation methods are classified into Eulerian and Lagrangian approaches where several measures have been proposed to quantify RT. Each of these methods has a di...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.028

    authors: Reza MMS,Arzani A

    更新日期:2019-05-09 00:00:00

  • Falls resulting from a laboratory-induced slip occur at a higher rate among individuals who are obese.

    abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.018

    authors: Allin LJ,Wu X,Nussbaum MA,Madigan ML

    更新日期:2016-03-21 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Effects of different initial foot positions on kinematics, muscle activation patterns, and postural control during a sit-to-stand in younger and older adults.

    abstract:BACKGROUND:Performing a sit-to-stand (STS) can be a challenging task for older adults because of age-related declines in neuromuscular strength and coordination. We investigated the effects of different initial foot positions (IFPs) on kinematics, muscle activation patterns, and balance control during a STS in younger ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110251

    authors: Jeon W,Hsiao HY,Griffin L

    更新日期:2021-01-13 00:00:00

  • Shoulder labral pathomechanics with rotator cuff tears.

    abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.036

    authors: Hwang E,Carpenter JE,Hughes RE,Palmer ML

    更新日期:2014-05-07 00:00:00