3D printed clamps improve spine specimen fixation in biomechanical testing.

Abstract:

:This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose, 16 thoracic and lumbar functional spine units of bovine, porcine, ovine and human cadavers (4 each) were consecutively fixed with all three techniques and loaded in six degrees of freedom. The combined relative movement between the cranial and caudal vertebral body and their corresponding fixtures were recorded using a 3D motion capture system. The 3D printed clamps did provide multiple advantages, showed no failures and the fixation rigidity was superior to potting in all loading directions and superior to screw-augmented potting in two of six loading directions (p < 0.05). In conclusion, the here proposed novel fixation method showed equal to superior properties in comparison to both other methods used in this study. When considering all characteristics of 3D printing, 3D printed fixtures can be an effective alternative to potting.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

doi

10.1016/j.jbiomech.2019.109467

subject

Has Abstract

pub_date

2020-01-02 00:00:00

pages

109467

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30717-1

journal_volume

98

pub_type

杂志文章
  • A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear.

    abstract::Brainstem trauma occurs frequently in severe head injury, often resulting in fatal lesions due to importance of brainstem in crucial neural functions. Structurally, the brainstem is composed of bundles of axonal fibers distinctly oriented in a longitudinal direction surrounded by an extracellular matrix. We hypothesiz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00042-1

    authors: Arbogast KB,Margulies SS

    更新日期:1999-08-01 00:00:00

  • Optimal patterns for suturing wounds of complex shapes to foster healing.

    abstract::Stress is one of the many biological factors that plays an important role in wound healing. It is therefore essential to analyze stresses around the wound closure theoretically, especially when no invasive/noninvasive technique to measure stress directly is available. The objective of this paper is to determine the re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00160-3

    authors: Lott-Crumpler DA,Chaudhry HR

    更新日期:2001-01-01 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: a comparison with ICRS and Mankin scores.

    abstract::In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.02.004

    authors: Abedian R,Willbold E,Becher C,Hurschler C

    更新日期:2013-04-26 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • A new testing device for measuring gliding resistance and work of flexion in a digit.

    abstract::In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00300-7

    authors: Zhao C,Amadio PC,Berglund L,Zobitz ME,An KN

    更新日期:2003-02-01 00:00:00

  • Velocities and stress levels of axisymmetric, azimuthal flow within the toroidal rotary seal of the IBM 2997 continuous flow cell separator and the implications.

    abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90163-6

    authors: Harvey CB,O'Rear EA

    更新日期:1986-01-01 00:00:00

  • Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    abstract::This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.020

    authors: Enders LR,Seo NJ

    更新日期:2011-05-17 00:00:00

  • The consequences of dehydration-hydration on bone anisotropy and implications on the sublamellar organization of mineralized collagen fibrils.

    abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109737

    authors: Utku FS

    更新日期:2020-05-07 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

    abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.025

    authors: Zioupos P,Hansen U,Currey JD

    更新日期:2008-10-20 00:00:00

  • Quantitative analysis of brain microstructure following mild blunt and blast trauma.

    abstract::We induced mild blunt and blast injuries in rats using a custom-built device and utilized in-house diffusion tensor imaging (DTI) software to reconstruct 3-D fiber tracts in brains before and after injury (1, 4, and 7 days). DTI measures such as fiber count, fiber length, and fractional anisotropy (FA) were selected t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.09.026

    authors: Begonia MT,Prabhu R,Liao J,Whittington WR,Claude A,Willeford B,Wardlaw J,Wu R,Zhang S,Williams LN

    更新日期:2014-11-28 00:00:00

  • Evaluation of brain-skull interface modelling approaches on the prediction of acute subdural hematoma in the elderly.

    abstract::Acute subdural hematoma (ASDH) in the elderly is currently a matter of concern due to the growing number of the aging population and their higher incident rate compared to the younger adults. Computational head models that can replicate this age-related injury pattern are valuable tools to help addressing this concern...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109787

    authors: Zhou Z,Li X,Kleiven S

    更新日期:2020-05-22 00:00:00

  • The role of synovial fluid filtration by cartilage in lubrication of synovial joints--II. Squeeze-film lubrication: homogeneous filtration.

    abstract::A mathematical model of synovial film filtration and synovial gel formation at normal approach of cartilage surfaces in the human hip joint is presented. The biphasic mixture model presented in Part I of this paper [Hlavácek, J. Biomechanics 26, (1993)] for synovial fluid and that of Mow and his collaborators [J. Biom...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90063-k

    authors: Hlavácek M

    更新日期:1993-10-01 00:00:00

  • Orofacial and thumb-index finger ramp-and-hold isometric force dynamics in young neurotypical adults.

    abstract::The relation among several parameters of the ramp-and-hold isometric force contraction (peak force and dF/dtmax during the initial phase of force recruitment, and the proportion of hold-phase at target) was quantified for the right and left thumb-index finger pinch, and lower lip midline compression in 40 neurotypical...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.031

    authors: Barlow SM,Hozan M,Lee J,Greenwood J,Custead R,Wardyn B,Tippin K

    更新日期:2018-04-27 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Mathematical model of microbicidal flow dynamics and optimization of rheological properties for intra-vaginal drug delivery: Role of tissue mechanics and fluid rheology.

    abstract::Topically applied microbicide gels can provide a self-administered and effective strategy to prevent sexually transmitted infections (STIs). We have investigated the interplay between vaginal tissue elasticity and the yield-stress of non-Newtonian fluids during microbicide deployment. We have developed a mathematical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.049

    authors: Anwar MR,Camarda KV,Kieweg SL

    更新日期:2015-06-25 00:00:00

  • Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

    abstract::The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.027

    authors: Arampatzis A,Morey-Klapsing G,Karamanidis K,DeMonte G,Stafilidis S,Brüggemann GP

    更新日期:2005-04-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • "Whither flows the fluid in bone?" An osteocyte's perspective.

    abstract::Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external enviro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(03)00123-4

    authors: Knothe Tate ML

    更新日期:2003-10-01 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Fracture properties of bovine tibial bone.

    abstract::Linear elastic fracture mechanics predicts that the fracture stress of precracked materials is dependent on the length of the initial crack tip radius of curvature, as supported by the Griffith and Inglis equations. In order to determine the applicability of these equations and the effects of other variables, tensile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90187-9

    authors: Moyle DD,Gavens AJ

    更新日期:1986-01-01 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • Hemodialysis arterio-venous graft design reducing the hemodynamic risk of vascular access dysfunction.

    abstract::Although arterio-venous grafts (AVGs) represent the second choice as permanent vascular access for hemodialysis, this solution is still affected by a relevant failure rate due to graft thrombosis, and development of neointimal hyperplasia (IH) at the distal vein. As a key role in these processes has been attributed to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109591

    authors: De Nisco G,Gallo D,Siciliano K,Tasso P,Lodi Rizzini M,Mazzi V,Calò K,Antonucci M,Morbiducci U

    更新日期:2020-02-13 00:00:00

  • On stiffness of scaffolds for bone tissue engineering-a numerical study.

    abstract::Tissue scaffolds are typically designed and fabricated to match native bone properties. However, it is unclear if this would lead to the best tissue ingrowth outcome within the scaffold as neo-tissue keeps changing the stiffness of entire construct. This paper presents a numerical method to address this issue for desi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.020

    authors: Sturm S,Zhou S,Mai YW,Li Q

    更新日期:2010-06-18 00:00:00

  • In vivo estimation of the glenohumeral joint centre by functional methods: accuracy and repeatability assessment.

    abstract::Several algorithms have been proposed for determining the centre of rotation of ball joints. These algorithms are used rather to locate the hip joint centre. Few studies have focused on the determination of the glenohumeral joint centre. However, no studies have assessed the accuracy and repeatability of functional me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.029

    authors: Lempereur M,Leboeuf F,Brochard S,Rousset J,Burdin V,Rémy-Néris O

    更新日期:2010-01-19 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Studies of human locomotion: past, present and future.

    abstract::The study of human locomotion and its applications are examined from a historical viewpoint. Several critical steps in the advancement of the discipline are considered in the context of addressing a particular need to answer fundamental questions regarding the process of human locomotion. In addition, changes in the m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(00)00061-0

    authors: Andriacchi TP,Alexander EJ

    更新日期:2000-10-01 00:00:00

  • Improvement of upper extremity kinematics estimation using a subject-specific forearm model implemented in a kinematic chain.

    abstract::Human movement reconstruction is still difficult due to noise generated by the use of skin markers. The a priori definition of a kinematic chain associated with a global optimisation method allows reducing these deleterious effects. When dealing with the forearm, this approach can be improved by personalising the two ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.01.029

    authors: Fohanno V,Lacouture P,Colloud F

    更新日期:2013-04-05 00:00:00