Abstract:
:Human movement reconstruction is still difficult due to noise generated by the use of skin markers. The a priori definition of a kinematic chain associated with a global optimisation method allows reducing these deleterious effects. When dealing with the forearm, this approach can be improved by personalising the two axes of rotation because their common modelling is not representative of joint geometry. The aim of the present study is to evaluate the kinematic effects of personalising these two axes of rotation, determined by a functional method and implemented in a kinematic chain (AXIS model). The AXIS model was compared with a reference model (ISB model), in which the forearm axes of rotation were defined according to the recommendations of the International Society of Biomechanics. The kinematic comparison (15 subjects and 3 tasks) was based on marker residuals (actual versus model-determined), joint kinematic root mean square differences (AXIS versus ISB) and joint amplitudes (AXIS versus ISB). The AXIS model improved the pose of the forearm and hand. The reduction in marker residuals for these segments ranged between 23% and 60%. The use of a functional method was also beneficial in personalising the flexion-extension and pronation-supination axes of the forearm. The contribution of pronation-supination, in terms of joint amplitudes, was increased by 15% during the specific task. The approach developed in this study is all the more interesting since this forearm model could be integrated into a kinematic chain to be used with a global approach becoming increasingly popular in biomechanics.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Fohanno V,Lacouture P,Colloud Fdoi
10.1016/j.jbiomech.2013.01.029subject
Has Abstractpub_date
2013-04-05 00:00:00pages
1053-9issue
6eissn
0021-9290issn
1873-2380pii
S0021-9290(13)00073-0journal_volume
46pub_type
杂志文章abstract::Mechanical fatigue of bone cement leading to damage accumulation is implicated in the loosening of cemented hip components. Even though cracks have been identified in autopsy-retrieved mantles, damage accumulation by continuous growth and increase in number of microcracks has not yet been demonstrated experimentally. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00018-4
更新日期:1999-05-01 00:00:00
abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.041
更新日期:2010-03-03 00:00:00
abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90076-d
更新日期:1992-10-01 00:00:00
abstract::During normal daily activity, muscle motor units (MUs) develop unfused tetanic contractions evoked by trains of motoneuronal firings at variable interpulse intervals (IPIs). The mechanical responses of a MU to successive impulses are not identical. The aim of this study was to develop a mathematical approach for the p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.01.034
更新日期:2010-05-28 00:00:00
abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.05.021
更新日期:2010-09-17 00:00:00
abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.036
更新日期:2014-05-07 00:00:00
abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.03.048
更新日期:2016-06-14 00:00:00
abstract::The use of a finite element based computational method, RFEM3D, is described for the study of strain-induced bone remodeling. The purpose of the research is to find the potential influence on the predictions of surface bone remodeling when various models for the maturation of newly deposited bone are used. A parameter...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90015-u
更新日期:1990-01-01 00:00:00
abstract::Arteries exhibit a remarkable ability to adapt to diverse genetic defects and sustained alterations in mechanical loading. For example, changes in blood flow induced wall shear stress tend to control arterial caliber and changes in blood pressure induced circumferential wall stress tend to control wall thickness. We s...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2008.11.011
更新日期:2009-01-05 00:00:00
abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90065-5
更新日期:1994-05-01 00:00:00
abstract::Posteroanterior spinal stiffness assessments are common in the evaluating patients with low back pain. The purpose of this study was to determine the effects of mechanical excitation frequency on dynamic lumbar spine stiffness. A computer-controlled voice coil actuator equipped with a load cell and LVDT was used to de...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.037
更新日期:2007-01-01 00:00:00
abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.12.014
更新日期:2014-03-21 00:00:00
abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90367-c
更新日期:1990-01-01 00:00:00
abstract::The estimation of the skeletal motion obtained from marker-based motion capture systems is known to be affected by significant bias caused by skin movement artifacts, which affects joint center and rotation axis estimation. Among different techniques proposed in the literature, that based on rigid body model, still th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.032
更新日期:2005-11-01 00:00:00
abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00172-5
更新日期:2002-01-01 00:00:00
abstract::The goal of the present study was to assess the effects of age and sex on trunk motor control. Fifty healthy adults (aged between 19 and 67 years, 28 males) participated in this study. Trunk motor control was assessed using force-controlled perturbations directly applied to the trunk. Admittance (inverse of lumped int...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109607
更新日期:2020-03-26 00:00:00
abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00057-x
更新日期:2002-07-01 00:00:00
abstract::A biomechanical model of the human thorax was constructed to investigate how asymmetric growth of the thorax might initiate spinal lateral curvature and axial rotation as seen in scoliosis deformities. Geometric data specifying nodal points of the model were taken from stereo-radiographs of an adolescent subject. An i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90051-4
更新日期:1990-01-01 00:00:00
abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.03.009
更新日期:2018-04-27 00:00:00
abstract::Sustained mechanical loading of skeletal muscle may result in the development of a severe type of pressure ulcer, referred to as deep tissue injury. Recently it was shown that the diffusion of large molecules (10-150kDa) is impaired during deformation of tissue-engineered skeletal muscle, suggesting a role for impaire...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.043
更新日期:2010-02-10 00:00:00
abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90365-l
更新日期:1993-03-01 00:00:00
abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.027
更新日期:2016-02-08 00:00:00
abstract::Cellular mechanics is known to play an important role in many cellular functions including adhesion, migration, proliferation, and differentiation. Human mesenchymal stem cells (hMSCs) demonstrate unique mechanical properties distinct from fully differentiated cells. This observation suggests that the stem cell mechan...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.024
更新日期:2011-10-13 00:00:00
abstract::In this paper we present a study of the post valvular flow field on a new cardiovascular simulator including an elastic model of the aortic arch. Transverse and vertical two-dimensional velocity measurements are performed with an ultrasonic velocimeter. Two prosthetic heart valves are tested in the aortic position. Th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90054-5
更新日期:1985-01-01 00:00:00
abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.016
更新日期:2014-03-03 00:00:00
abstract::The methods of evaluation of mechanical energy economy during human movement based on the calculation of three different values of work (Wwb, Ww, Wn), corresponding to three hypothetical types of energy exchange, are subject to criticism. Only the value of work, Wwb, calculated under the assumption of energy transfers...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90006-0
更新日期:1986-01-01 00:00:00
abstract::Body weight support (BWS) systems are a common tool used in gait rehabilitation. BWS systems may alter the requirements for an individual to actively stabilize by 1) providing lateral restoring forces that reduce the requirements for the nervous system to actively stabilize and 2) decreasing the stabilizing gravitatio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.026
更新日期:2016-09-06 00:00:00
abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.040
更新日期:2010-08-26 00:00:00
abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.045
更新日期:2012-02-02 00:00:00
abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.026
更新日期:2010-10-19 00:00:00