An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

Abstract:

:Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a standard motion capture protocol. Fourteen participants underwent instrumented barefoot analysis of foot motion during gait. Markers were attached to foot allowing medial longitudinal arch angle and navicular height to be determined. For the US/MC technique, the navicular marker was replaced by an ultrasound transducer which was secured to the foot allowing the skeletal landmark to be imaged. Ultrasound cineloops showing the location of the navicular tuberosity during the walking trials were synchronised with motion capture measurements and markers mounted on the probe allowed the true position of the bony landmark to be determined throughout stance phase. Two discrete variables, minimum navicular height and maximum MLA angle, were compared between the standard and US/MC protocols. Significant differences between minimum navicular height (P=0.004, 95% CI (1.57, 6.54)) and maximum medial longitudinal arch angle (P=0.0034, 95% CI (13.8, 3.4)) were found between the measurement methods. The individual effects of STA and marker placement error were also assessed. US/MC is a non-invasive technique which may help to provide more accurate measurements of intrinsic foot kinematics.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Telfer S,Woodburn J,Turner DE

doi

10.1016/j.jbiomech.2013.12.014

subject

Has Abstract

pub_date

2014-03-21 00:00:00

pages

1225-8

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00641-6

journal_volume

47

pub_type

杂志文章
  • Rotational kinematics of pelvis and upper trunk at butterfly stroke: Can fins affect the dynamics of the system?

    abstract::The purpose of the present study was to investigate the rotational kinematics pattern of the upper trunk and the pelvis and the complexity-variability of their movement, during the sprint butterfly stroke between male and female swimmers with long fins (18-26 cm) and without fins. Two pairs of 3D accelerometers and gy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.004

    authors: Averianova A,Nikodelis T,Konstantakos V,Kollias I

    更新日期:2016-02-08 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Challenges to bone formation in spinal fusion.

    abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2010.10.021

    authors: Reid JJ,Johnson JS,Wang JC

    更新日期:2011-01-11 00:00:00

  • Effect of high altitude exposure on the hemodynamics of the bidirectional Glenn physiology: modeling incremented pulmonary vascular resistance and heart rate.

    abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.021

    authors: Vallecilla C,Khiabani RH,Sandoval N,Fogel M,Briceño JC,Yoganathan AP

    更新日期:2014-06-03 00:00:00

  • Associations of hamstring and triceps surae muscle spasticity and stance phase gait kinematics in children with spastic diplegic cerebral palsy.

    abstract::Clinical decisions on interventions to improve function in children with cerebral palsy (CP) are based, in part, on hypothesized interactions amongst physical signs of CP and functional deficits. However, a knowledge gap exists regarding associations between spasticity and gait function. This study quantified associat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110218

    authors: Bowal N,Nettel-Aguirre A,Ursulak G,Condliffe E,Robu I,Goldstein S,Emery C,Ronsky JL,Kuntze G

    更新日期:2021-01-16 00:00:00

  • Explaining Parkinsonian postural sway variabilities using intermittent control theory.

    abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109791

    authors: Dash R,Shah VV,Palanthandalam-Madapusi HJ

    更新日期:2020-05-22 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?

    abstract::Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, lik...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.004

    authors: Luraghi G,Wu W,De Gaetano F,Rodriguez Matas JF,Moggridge GD,Serrani M,Stasiak J,Costantino ML,Migliavacca F

    更新日期:2017-06-14 00:00:00

  • A biomechanical analysis of venous tissue in its normal and post-phlebitic conditions.

    abstract::Although biomechanical studies of the normal rat vein wall have been reported (Weizsacker, 1988; Plante, 2002), there are no published studies that have investigated the mechanical effects of thrombus formation on murine venous tissue. In response to the lack of knowledge concerning the mechanical consequences of thro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.012

    authors: McGilvray KC,Sarkar R,Nguyen K,Puttlitz CM

    更新日期:2010-11-16 00:00:00

  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • Effect of material damping on bone remodelling.

    abstract::This paper considers the effect of internal material damping on the stresses, strains, and surface and internal remodelling behaviour in a section of axisymmetrical bone with a force-fitted axially oriented medullary pin. The bone response to several loading situations is modelled using visco-elastic equations. An app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90291-0

    authors: Misra JC,Samanta S

    更新日期:1987-01-01 00:00:00

  • The effect of swimming activity on bone architecture in growing rats.

    abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90068-7

    authors: Simkin A,Leichter I,Swissa A,Samueloff S

    更新日期:1989-01-01 00:00:00

  • Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal.

    abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.035

    authors: Cacciari LP,Pássaro AC,Amorim AC,Geuder M,Sacco ICN

    更新日期:2017-06-14 00:00:00

  • Bone strain sensation via transmembrane potential changes in surface osteoblasts: loading rate and microstructural implications.

    abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90048-j

    authors: Harrigan TP,Hamilton JJ

    更新日期:1993-02-01 00:00:00

  • Thickness, cross-sectional area, and stiffness of intrinsic foot muscles affect performance in single-leg stance balance tests in healthy sedentary young females.

    abstract::The purpose of this study was to investigate the effect of thickness, cross-sectional area and stiffness of intrinsic foot muscles on performance in single-leg stance balance tasks in healthy sedentary young females. This study included a total of 40 healthy sedentary young females between the ages of 19 and 35 years....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109530

    authors: Taş S,Ünlüer NÖ,Çetin A

    更新日期:2020-01-23 00:00:00

  • Mechanical interaction of center of pressure and force direction in the upright human.

    abstract::Humans maintain upright bipedal posture by producing appropriate force against the environment through the interaction of neural controlled muscle force with the mechanics of the skeletal system. Characterizing these mechanics facilitates understanding of the neural control. We used a mechanical model of an upright hu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.018

    authors: Gruben KG,Boehm WL

    更新日期:2012-06-01 00:00:00

  • Maximum height and minimum time vertical jumping.

    abstract::The performance criterion in maximum vertical jumping has typically been assumed to simply raise the center of mass as high as possible. In many sporting activities minimizing movement time during the jump is likely also critical to successful performance. The purpose of this study was to examine maximum height jumps ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.021

    authors: Domire ZJ,Challis JH

    更新日期:2015-08-20 00:00:00

  • Precision measurements of the RSA method using a phantom model of hip prosthesis.

    abstract::Radiostereometric analysis (RSA) has become one of the recommended techniques for pre-market evaluation of new joint implant designs. In this study we evaluated the effect of repositioning of X-ray tubes and phantom model on the precision of the RSA method. In precision measurements, we utilized mean error of rigid bo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.004

    authors: Mäkinen TJ,Koort JK,Mattila KT,Aro HT

    更新日期:2004-04-01 00:00:00

  • Application of strain and calibration of Förster Resonance Energy Transfer (FRET) emission for in vitro live cell response to cytoskeletal deformation.

    abstract::Cellular mechanotransduction is an integral part of many crucial physiological processes, but non-invasive tools for quantifying intracellular strain in vivo are not available for complex tissues such as bone. As a first step to address this gap, we have utilized a novel, non-invasive approach to quantify cellular str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.023

    authors: Knorr JM,Jackson J,Batie MR,Narmoneva DA,Jones DC

    更新日期:2016-10-03 00:00:00

  • Influence of stent height upon stresses on the cusps of closed bioprosthetic valves.

    abstract::A finite element model of a bioprosthetic heart valve was developed to determine the influence of the stent height on leaflet stresses under various pressure loading conditions after valve closure. A nonlinear solution was used to obtain the stresses in the leaflets for stent heights of 14.6 mm, 19.0 mm and 22.0 mm re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90199-5

    authors: Hamid MS,Sabbah HN,Stein PD

    更新日期:1986-01-01 00:00:00

  • Does weightlifting increase residual force enhancement?

    abstract::The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions du...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.017

    authors: Siebert T,Kurch D,Blickhan R,Stutzig N

    更新日期:2016-07-05 00:00:00

  • Compliance calibration for fracture testing of equine cortical bone.

    abstract::An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for cra...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00009-x

    authors: Malik CL,Gibeling JC,Martin RB,Stover SM

    更新日期:2002-05-01 00:00:00

  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Effect of simulated joint instability and bracing on ankle and subtalar joint flexibility.

    abstract::It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.033

    authors: Choisne J,McNally A,Hoch MC,Ringleb SI

    更新日期:2019-01-03 00:00:00

  • The influences of foot placement on lumbopelvic rhythm during trunk flexion motion.

    abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.048

    authors: Zhou J,Ning X,Hu B,Dai B

    更新日期:2016-06-14 00:00:00

  • Static optimal estimation of joint accelerations for inverse dynamics problem solution.

    abstract::In inverse dynamics computations, the accuracy of the solution strongly depends on the accuracy of the input data. In particular, estimated joint moments are highly sensitive to uncertainties in acceleration data. The aim of the present work was to improve classical inverse dynamics computations by providing an accura...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00176-8

    authors: Cahouët V,Luc M,David A

    更新日期:2002-11-01 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00