Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

Abstract:

:One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Faustino V,Catarino SO,Lima R,Minas G

doi

10.1016/j.jbiomech.2015.11.031

subject

Has Abstract

pub_date

2016-07-26 00:00:00

pages

2280-2292

issue

11

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(15)00673-9

journal_volume

49

pub_type

杂志文章,评审
  • Runners adjust leg stiffness for their first step on a new running surface.

    abstract::Human runners adjust the stiffness of their stance leg to accommodate surface stiffness during steady state running. This adjustment allows runners to maintain similar center of mass movement (e.g., ground contact time and stride frequency) regardless of surface stiffness. When runners encounter abrupt transitions in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(99)00078-0

    authors: Ferris DP,Liang K,Farley CT

    更新日期:1999-08-01 00:00:00

  • Glenohumeral joint cartilage contact in the healthy adult during scapular plane elevation depression with external humeral rotation.

    abstract::The shoulder (glenohumeral) joint has the greatest range of motion of all human joints; as a result, it is particularly vulnerable to dislocation and injury. The ability to non-invasively quantify in-vivo articular cartilage contact patterns of joints has been and remains a difficult biomechanics problem. As a result,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.034

    authors: Massimini DF,Warner JJ,Li G

    更新日期:2014-09-22 00:00:00

  • Rotational kinematics of pelvis and upper trunk at butterfly stroke: Can fins affect the dynamics of the system?

    abstract::The purpose of the present study was to investigate the rotational kinematics pattern of the upper trunk and the pelvis and the complexity-variability of their movement, during the sprint butterfly stroke between male and female swimmers with long fins (18-26 cm) and without fins. Two pairs of 3D accelerometers and gy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.004

    authors: Averianova A,Nikodelis T,Konstantakos V,Kollias I

    更新日期:2016-02-08 00:00:00

  • Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

    abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.046

    authors: Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

    更新日期:2015-04-13 00:00:00

  • Long-term implant fixation and stress-shielding in total hip replacement.

    abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.12.021

    authors: Sumner DR

    更新日期:2015-03-18 00:00:00

  • Orofacial and thumb-index finger ramp-and-hold isometric force dynamics in young neurotypical adults.

    abstract::The relation among several parameters of the ramp-and-hold isometric force contraction (peak force and dF/dtmax during the initial phase of force recruitment, and the proportion of hold-phase at target) was quantified for the right and left thumb-index finger pinch, and lower lip midline compression in 40 neurotypical...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.031

    authors: Barlow SM,Hozan M,Lee J,Greenwood J,Custead R,Wardyn B,Tippin K

    更新日期:2018-04-27 00:00:00

  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure.

    abstract::Accidentology data showed that liver is often injured in car crashes; three types of injuries occur: hematoma, laceration and vessel failure. This paper focuses on surface laceration, which involves liver capsule and hepatic parenchyma. Liver capsule behavior has been studied but its failure properties are still uncle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.038

    authors: Brunon A,Bruyère-Garnier K,Coret M

    更新日期:2010-08-10 00:00:00

  • Sensitivity of temporomandibular joint force calculations to errors in muscle force measurements.

    abstract::A two-dimensional, five-muscle model was used to determine the degree of precision required for accurate calculation of temporomandibular joint force magnitude and direction. The sensitivity of the calculations to each variable were assessed by incrementing each variable through its presumed biological range and were ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90206-6

    authors: Throckmorton GS

    更新日期:1989-01-01 00:00:00

  • Static optimal estimation of joint accelerations for inverse dynamics problem solution.

    abstract::In inverse dynamics computations, the accuracy of the solution strongly depends on the accuracy of the input data. In particular, estimated joint moments are highly sensitive to uncertainties in acceleration data. The aim of the present work was to improve classical inverse dynamics computations by providing an accura...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00176-8

    authors: Cahouët V,Luc M,David A

    更新日期:2002-11-01 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    abstract::Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utiliz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.011

    authors: Schiffman JM,Chelidze D,Adams A,Segala DB,Hasselquist L

    更新日期:2009-09-18 00:00:00

  • Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

    abstract::The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of tempera...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.011

    authors: Moriya T,Chikenji T,Thoreson AR,Zhao C,An KN,Amadio PC

    更新日期:2011-04-29 00:00:00

  • Design of next generation total disk replacements.

    abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.017

    authors: van den Broek PR,Huyghe JM,Wilson W,Ito K

    更新日期:2012-01-03 00:00:00

  • Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

    abstract::The structure and function of the renal artery ostium flow diverter on the caudal side of the renal branch point were previously reported; in this study, we further evaluate the diverter׳s possible functions. The protrusion of this structure into the abdominal aorta suggests that the diverter may preferentially direct...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.006

    authors: Albert S,Balaban RS,Neufeld EB,Rossmann JS

    更新日期:2014-05-07 00:00:00

  • Analysis of thoracic aorta hemodynamics using 3D particle tracking velocimetry and computational fluid dynamics.

    abstract::Parallel to the massive use of image-based computational hemodynamics to study the complex flow establishing in the human aorta, the need for suitable experimental techniques and ad hoc cases for the validation and benchmarking of numerical codes has grown more and more. Here we present a study where the 3D pulsatile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.017

    authors: Gallo D,Gülan U,Di Stefano A,Ponzini R,Lüthi B,Holzner M,Morbiducci U

    更新日期:2014-09-22 00:00:00

  • Motion of the residual femur within the socket during gait is associated with patient-reported problems in transfemoral amputees.

    abstract::The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110050

    authors: Gale T,Yang S,McGough R,Fiedler G,Anderst W

    更新日期:2020-11-09 00:00:00

  • A force plate study of avian gait.

    abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.014

    authors: Corr SA,McCorquodale C,McDonald J,Gentle M,McGovern R

    更新日期:2007-01-01 00:00:00

  • Triceps surae muscle-tendon unit length changes as a function of ankle joint angles and contraction levels: the effect of foot arch deformation.

    abstract::The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.003

    authors: Iwanuma S,Akagi R,Hashizume S,Kanehisa H,Yanai T,Kawakami Y

    更新日期:2011-09-23 00:00:00

  • Influence of stent height upon stresses on the cusps of closed bioprosthetic valves.

    abstract::A finite element model of a bioprosthetic heart valve was developed to determine the influence of the stent height on leaflet stresses under various pressure loading conditions after valve closure. A nonlinear solution was used to obtain the stresses in the leaflets for stent heights of 14.6 mm, 19.0 mm and 22.0 mm re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90199-5

    authors: Hamid MS,Sabbah HN,Stein PD

    更新日期:1986-01-01 00:00:00

  • A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation.

    abstract::Leakage of blood alongside the implant is a relatively frequent and life-limiting complication after transcatheter aortic valve implantation. The aim of this study is to develop and validate a workflow to simulate the implantation prior to the intervention. Based on the simulation outcome, the amount of leakage is est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.024

    authors: Bosmans B,Famaey N,Verhoelst E,Bosmans J,Vander Sloten J

    更新日期:2016-09-06 00:00:00

  • Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants.

    abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.036

    authors: Massaroni C,Piaia Silvatti A,Levai IK,Dickinson J,Winter S,Schena E,Silvestri S

    更新日期:2018-07-25 00:00:00

  • In-vivo 6 degrees-of-freedom kinematics of metal-on-polyethylene total hip arthroplasty during gait.

    abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.012

    authors: Tsai TY,Li JS,Wang S,Scarborough D,Kwon YM

    更新日期:2014-05-07 00:00:00

  • On the anisotropy of the canine diaphragmatic central tendon.

    abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90289-y

    authors: Chuong CJ,Sacks MS,Johnson RL Jr,Reynolds R

    更新日期:1991-01-01 00:00:00

  • A new in vivo technique for determination of femoro-tibial and femoro-patellar 3D kinematics in total knee arthroplasty.

    abstract::Aim was to develop an in vivo technique which allows determination of femoro-tibial and of femoro-patellar 3D-kinematics in TKA simultaneously. The knees of 20 healthy volunteers and of eight patients with TKA (PCR, rotating platform) were investigated. Kinematics analysis was performed in an open MR-system at differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.020

    authors: von Eisenhart-Rothe R,Vogl T,Englmeier KH,Graichen H

    更新日期:2007-01-01 00:00:00

  • Validation of predicted patellofemoral mechanics in a finite element model of the healthy and cruciate-deficient knee.

    abstract::Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.020

    authors: Ali AA,Shalhoub SS,Cyr AJ,Fitzpatrick CK,Maletsky LP,Rullkoetter PJ,Shelburne KB

    更新日期:2016-01-25 00:00:00

  • Load transfer across the pelvic bone.

    abstract::Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00125-n

    authors: Dalstra M,Huiskes R

    更新日期:1995-06-01 00:00:00

  • A little bit faster: Lower extremity joint kinematics and kinetics as recreational runners achieve faster speeds.

    abstract::There appears a linear relationship between small increases in running speed and cardiovascular health benefits. Encouraging or coaching recreational runners to increase their running speed to derive these health benefits might be more effective if their joint level kinematic and kinetic strategy was understood. The a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.010

    authors: Orendurff MS,Kobayashi T,Tulchin-Francis K,Tullock AMH,Villarosa C,Chan C,Kraus E,Strike S

    更新日期:2018-04-11 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00