Abstract:
:The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-reported comfort and function. The secondary goals were to assess within-subject step-to-step variability and between-subject variability in residual femur motion within the socket during gait. Dynamic biplane radiography, combined with conventional motion capture, was used to measure residual femur motion within the socket during treadmill walking for 10 unilateral transfemoral amputees. The questionnaire for persons with a transfemoral amputation (Q-TFA) was administered to assess prosthetic use, mobility, health problems, and global health. Increased femur pistoning (proximal-distal translation relative to the socket) correlated with worsening Q-TFA problem and global scores (ρ = 0.741, p = 0.04 and ρ = -0.783, p = 0.02, respectively). Average residual femur rotation ROMs were 7.3°±3.7°, 10.8°±4.4°, and 7.7°±4.8° for anterior tilt, internal-external rotation, and varus-valgus, respectively. Average residual femur translation ROMs were 8.6 mm ± 3.0 mm, 28.4 mm ± 13.9 mm, and 20.4 mm ± 7.2 mm for medial-lateral, pistoning, and anterior-posterior directions, respectively. Within-subject rotational and translational variability during gait averaged 2.8° and 2.0 mm or less, whereas the between-subject variability was up to 9.4° and 18.6 mm, which demonstrates residual femur motion relative to the socket is repeatable within subjects, but inconsistent across subjects during gait. The results suggest residual bone motion within the socket is a potential mechanism behind patient-reported problems and suggests a target for intervention aimed at improving transfemoral amputee quality of life.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Gale T,Yang S,McGough R,Fiedler G,Anderst Wdoi
10.1016/j.jbiomech.2020.110050subject
Has Abstractpub_date
2020-11-09 00:00:00pages
110050eissn
0021-9290issn
1873-2380pii
S0021-9290(20)30474-7journal_volume
112pub_type
杂志文章abstract::A three-dimensional model of the lower limb containing 47 muscles was developed to study the differences between a two- and three-dimensional approach for determining internal loads, the role of the dynamic joint representation, and the behavior of different load-bearing criteria in walking and running. The problem of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00089-4
更新日期:1997-11-01 00:00:00
abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.05.030
更新日期:2015-09-18 00:00:00
abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.023
更新日期:2018-03-21 00:00:00
abstract::Heart valves induce flow disturbances which play a role in blood cell activation and damage, but questions of the magnitude and spatial distribution of fluid stresses (wall shear stress and turbulent stress) cannot be readily addressed with current experimental techniques. Therefore, a numerical simulation procedure f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90015-9
更新日期:1994-04-01 00:00:00
abstract::Despite significant evidence regarding the increased risk of cartilage degeneration due to traumatic injuries to joints, there is still a lack of understanding of the mechanisms underlying osteoarthritis development following a joint injury. Injuries in knee cartilage are often characterized by lesions or tears. In ad...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109970
更新日期:2020-09-18 00:00:00
abstract::Previous research on slip and fall accidents has suggested that pressurized fluid between the shoe and floor is responsible for initiating slips yet this effect has not been verified experimentally. This study aimed to (1) measure hydrodynamic pressures during slipping for treaded and untreaded conditions; (2) determi...
journal_title:Journal of biomechanics
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.jbiomech.2013.10.046
更新日期:2014-01-22 00:00:00
abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.016
更新日期:2010-11-16 00:00:00
abstract::The relation among several parameters of the ramp-and-hold isometric force contraction (peak force and dF/dtmax during the initial phase of force recruitment, and the proportion of hold-phase at target) was quantified for the right and left thumb-index finger pinch, and lower lip midline compression in 40 neurotypical...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.02.031
更新日期:2018-04-27 00:00:00
abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.12.011
更新日期:2007-01-01 00:00:00
abstract::Rabbits were immobilized for 3 weeks with the ankle in plantar flexion, midrange position or dorsal extension (n=15). The left leg was used as control. Sarcomere lengths were measured by laser diffraction in vivo in the tibialis anterior (TA) muscle. Legs immobilized in the midrange position showed coherent diffractio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.006
更新日期:2008-01-01 00:00:00
abstract::There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.013
更新日期:2015-03-18 00:00:00
abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90201-1
更新日期:1994-02-01 00:00:00
abstract::The effect of stress deprivation on the tendon tissue has been an important focus in the field of biomechanics. However, less is known about the in vivo effect of stress deprivation on fibroblast apoptosis as of yet. This study was conducted to test a hypothesis that complete stress deprivation of the patellar tendon ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.027
更新日期:2009-11-13 00:00:00
abstract::To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Meas...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90150-8
更新日期:1986-01-01 00:00:00
abstract::The reverse shoulder prosthesis aims to restore the stability and function of pathological shoulders, but the biomechanical aspects of the geometrical changes induced by the implant are yet to be fully understood. Considering a large-scale musculoskeletal model of the upper limb, the aim of this study is to evaluate h...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.06.031
更新日期:2015-09-18 00:00:00
abstract::Adverse wall shear stress (WSS) patterns are known to play a key role in the localisation, formation, and progression of intracranial aneurysms (IAs). Complex region-specific and time-varying aneurysmal WSS patterns depend both on vascular morphology as well as on variable systemic flow conditions. Computational fluid...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.10.005
更新日期:2016-12-08 00:00:00
abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00050-5
更新日期:1998-07-01 00:00:00
abstract::A challenging aspect of subject specific musculoskeletal modeling is the estimation of muscle parameters, especially optimal fiber length and tendon slack length. In this study, the method for scaling musculotendon parameters published by Winby et al. (2008), J. Biomech. 41, 1682-1688, has been reformulated, generaliz...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.11.006
更新日期:2016-01-25 00:00:00
abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90163-6
更新日期:1986-01-01 00:00:00
abstract::Anesthetized, carefully positioned, female, weanling, white-haired pigs were used to test the hypothesis that (1) interface pressure, the pressure between the skin and an external load, can be used to predict the interstitial fluid pressure over the wings of ilia and the last dorsal spinous process and (2) three-dimen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90322-e
更新日期:1991-01-01 00:00:00
abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.09.014
更新日期:2007-01-01 00:00:00
abstract::In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The me...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.08.030
更新日期:2017-12-08 00:00:00
abstract::Bone is a biological nanocomposite composed primarily of collagen and hydroxyapatite. The collagen molecules self-assemble to from a structure known as a fibril that comprises of about 85-95% of the total bone protein. In a fibril, the molecular level interactions at the interface between molecular collagen and hydrox...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.027
更新日期:2010-06-18 00:00:00
abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2012.03.027
更新日期:2012-06-01 00:00:00
abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.013
更新日期:2010-10-19 00:00:00
abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.021
更新日期:2014-06-03 00:00:00
abstract::A mathematical model is introduced to investigate the influence of the physical properties of the resistance vessel wall on the metabolic and myogenic mechanisms. The resistance vessel wall is assumed to have an elastic property and the elastic modulus to be a function of pressure (myogenic) and flow (metabolic). Bloo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90033-x
更新日期:1989-01-01 00:00:00
abstract::The ability to visualize and interpret high dimensional time-series data will be critical as wearable and other sensors are adopted in rehabilitation protocols. This study proposes a latent space representation of high dimensional time-series data for data visualization. For that purpose, a deep learning model called ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109684
更新日期:2020-04-16 00:00:00
abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.015
更新日期:2011-09-23 00:00:00
abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.11.009
更新日期:2008-01-01 00:00:00