The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint.

Abstract:

:In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The mechanical properties of ligaments can be based on literature, or adjusted specifically for the subject. In the current study we investigated the effect of ligament modelling strategy on the predictive capability of FE models of the human knee joint. The effect of literature-based versus specimen-specific optimized material parameters was evaluated. Experiments were performed on three human cadaver knees, which were modelled in FE models with ligaments represented either using springs, or using continuum representations. In spring representation collateral ligaments were each modelled with three and cruciate ligaments with two single-element bundles. Stiffness parameters and pre-strains were optimized based on laxity tests for both approaches. Validation experiments were conducted to evaluate the outcomes of the FE models. Models (both spring and continuum) with subject-specific properties improved the predicted kinematics and contact outcome parameters. Models incorporating literature-based parameters, and particularly the spring models (with the representations implemented in this study), led to relatively high errors in kinematics and contact pressures. Using a continuum modelling approach resulted in more accurate contact outcome variables than the spring representation with two (cruciate ligaments) and three (collateral ligaments) single-element-bundle representations. However, when the prediction of joint kinematics is of main interest, spring ligament models provide a faster option with acceptable outcome.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot N

doi

10.1016/j.jbiomech.2017.08.030

subject

Has Abstract

pub_date

2017-12-08 00:00:00

pages

1-11

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(17)30452-9

journal_volume

65

pub_type

杂志文章
  • Squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage with the superficial zone worn out.

    abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00109-3

    authors: Hlavácek M

    更新日期:2000-11-01 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • Continuum modeling of deformation and aggregation of red blood cells.

    abstract::In order to gain better understanding for rheology of an isolated red blood cell (RBC) and a group of multiple RBCs, new continuum models for describing mechanical properties of cellular structures of an RBC and inter-cellular interactions among multiple RBCs are developed. The viscous property of an RBC membrane, whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.027

    authors: Yoon D,You D

    更新日期:2016-07-26 00:00:00

  • Versatile and inexpensive Hall-Effect force sensor for mechanical characterization of soft biological materials.

    abstract::Mismatch of hierarchical structure and mechanical properties between tissue-engineered implants and native tissue may result in signal cues that negatively impact repair and remodeling. With bottom-up tissue engineering approaches, designing tissue components with proper microscale mechanical properties is crucial to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.065

    authors: Backman DE,LeSavage BL,Wong JY

    更新日期:2017-01-25 00:00:00

  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee.

    abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90378-g

    authors: Pennock GR,Clark KJ

    更新日期:1990-01-01 00:00:00

  • Effect of vibration magnitude, vibration spectrum and muscle tension on apparent mass and cross axis transfer functions during whole-body vibration exposure.

    abstract::Twelve seated male subjects were exposed to 15 vibration conditions to investigate the nature and mechanisms of the non-linearity in biomechanical response. Subjects were exposed to three groups of stimuli: Group A comprised three repeats of random vertical vibration at 0.5, 1.0 and 1.5 ms(-2) r.m.s. with subjects sit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.09.024

    authors: Mansfield NJ,Holmlund P,Lundström R,Lenzuni P,Nataletti P

    更新日期:2006-01-01 00:00:00

  • Modela-r as a Froude and Strouhal dimensionless numbers combination for dynamic similarity in running.

    abstract::The aim of this study was to test the hypothesis that running at fixed fractions of Froude (Nfr) and Strouhal (Str) dimensionless numbers combinations induce dynamic similarity between humans of different sizes. Nineteen subjects ran in three experimental conditions, (i) constant speed, (ii) similar speed (Nfr) and (i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.012

    authors: Villeger D,Costes A,Watier B,Moretto P

    更新日期:2014-12-18 00:00:00

  • Collagen fibril diameters increase and fibril densities decrease in skin subjected to repetitive compressive and shear stresses.

    abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00145-2

    authors: Sanders JE,Goldstein BS

    更新日期:2001-12-01 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Effect of non-Newtonian fluid properties on bovine sperm motility.

    abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.005

    authors: Hyakutake T,Suzuki H,Yamamoto S

    更新日期:2015-09-18 00:00:00

  • Mechanical and material properties of the plantarflexor muscles and Achilles tendon in children with spastic cerebral palsy and typically developing children.

    abstract:BACKGROUND:Children with spastic cerebral palsy (CP) experience secondary musculoskeletal adaptations, affecting the mechanical and material properties of muscles and tendons. CP-related changes in the spastic muscle are well documented whilst less is known about the tendon. From a clinical perspective, it is important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.020

    authors: Theis N,Mohagheghi AA,Korff T

    更新日期:2016-09-06 00:00:00

  • Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle.

    abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.005

    authors: Chi SW,Hodgson J,Chen JS,Reggie Edgerton V,Shin DD,Roiz RA,Sinha S

    更新日期:2010-05-07 00:00:00

  • Thigh-calf contact parameters for six high knee flexion postures: Onset, maximum angle, total force, contact area, and center of force.

    abstract::In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.022

    authors: Kingston DC,Acker SM

    更新日期:2018-01-23 00:00:00

  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines.

    abstract::The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.038

    authors: Anderson DE,Mannen EM,Sis HL,Wong BM,Cadel ES,Friis EA,Bouxsein ML

    更新日期:2016-05-03 00:00:00

  • Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

    abstract::The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of tempera...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.011

    authors: Moriya T,Chikenji T,Thoreson AR,Zhao C,An KN,Amadio PC

    更新日期:2011-04-29 00:00:00

  • Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions.

    abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.023

    authors: Chevalier Y,Matsuura M,Krüger S,Fleege C,Rickert M,Rauschmann M,Schilling C

    更新日期:2018-03-21 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Propulsion biomechanics do not differ between athletic and nonathletic manual wheelchair users in their daily wheelchairs.

    abstract::The purpose of this study was to investigate whether athletic and nonathletic manual wheelchair users (MWU) display differences in kinetic and kinematic variables during daily wheelchair propulsion. Thirty-nine manual wheelchair users (athletic n = 25; nonathletic n = 14) propelled their own daily living wheelchair on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109725

    authors: Briley SJ,Vegter RJK,Tolfrey VL,Mason BS

    更新日期:2020-05-07 00:00:00

  • Wall shear stress distribution in the human carotid siphon during pulsatile flow.

    abstract::Wall shear stress distribution in the carotid siphon, which is a multiple curved segment of the internal carotid artery, is investigated numerically under physiological flow conditions. The computer simulation of flow through the model segment is based on the time-dependent, three-dimensional Navier-Stokes equations, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90203-5

    authors: Perktold K,Florian H,Hilbert D,Peter R

    更新日期:1988-01-01 00:00:00

  • Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

    abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.003

    authors: Nawayseh N,Hamdan S

    更新日期:2019-01-03 00:00:00

  • Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension.

    abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.009

    authors: Lyons M,Winter DC,Simms CK

    更新日期:2014-06-03 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00