Abstract:
:In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The mechanical properties of ligaments can be based on literature, or adjusted specifically for the subject. In the current study we investigated the effect of ligament modelling strategy on the predictive capability of FE models of the human knee joint. The effect of literature-based versus specimen-specific optimized material parameters was evaluated. Experiments were performed on three human cadaver knees, which were modelled in FE models with ligaments represented either using springs, or using continuum representations. In spring representation collateral ligaments were each modelled with three and cruciate ligaments with two single-element bundles. Stiffness parameters and pre-strains were optimized based on laxity tests for both approaches. Validation experiments were conducted to evaluate the outcomes of the FE models. Models (both spring and continuum) with subject-specific properties improved the predicted kinematics and contact outcome parameters. Models incorporating literature-based parameters, and particularly the spring models (with the representations implemented in this study), led to relatively high errors in kinematics and contact pressures. Using a continuum modelling approach resulted in more accurate contact outcome variables than the spring representation with two (cruciate ligaments) and three (collateral ligaments) single-element-bundle representations. However, when the prediction of joint kinematics is of main interest, spring ligament models provide a faster option with acceptable outcome.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot Ndoi
10.1016/j.jbiomech.2017.08.030subject
Has Abstractpub_date
2017-12-08 00:00:00pages
1-11eissn
0021-9290issn
1873-2380pii
S0021-9290(17)30452-9journal_volume
65pub_type
杂志文章abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/S0021-9290(03)00251-3
更新日期:2004-09-01 00:00:00
abstract::Data on articular cartilage thickness in the living are important for the design for computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)81146-3
更新日期:1997-03-01 00:00:00
abstract::Platelet activation under blood flow is thought to be critically dependent on the autologous secretion of soluble platelet agonists (chemical activators) such as ADP and thromboxane. However, recent evidence challenging this model suggests that platelet activation can occur independent of soluble agonist signalling, i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.006
更新日期:2011-04-07 00:00:00
abstract::Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utiliz...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.011
更新日期:2009-09-18 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.12.019
更新日期:2017-02-28 00:00:00
abstract::Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stem...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.10.006
更新日期:2008-01-01 00:00:00
abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90360-f
更新日期:1990-01-01 00:00:00
abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.016
更新日期:2010-11-16 00:00:00
abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.021
更新日期:2014-06-03 00:00:00
abstract::It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of mo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.10.033
更新日期:2019-01-03 00:00:00
abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.026
更新日期:2014-06-03 00:00:00
abstract::Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.02.010
更新日期:2013-04-26 00:00:00
abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.037
更新日期:2014-07-18 00:00:00
abstract::The maintenance of steady contractions is required in many daily tasks. However, there is little understanding of how various lower limb configurations influence the ability to maintain force. The purpose of the current investigation was to examine the influence of joint angle on various lower-limb constant force cont...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.032
更新日期:2018-04-11 00:00:00
abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.014
更新日期:2005-10-01 00:00:00
abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.004
更新日期:2010-05-07 00:00:00
abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.05.010
更新日期:2010-09-17 00:00:00
abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.03.031
更新日期:2011-06-03 00:00:00
abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.008
更新日期:2010-02-10 00:00:00
abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.016
更新日期:2019-01-23 00:00:00
abstract::There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.013
更新日期:2015-03-18 00:00:00
abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.016
更新日期:2017-10-03 00:00:00
abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.02.006
更新日期:2018-04-11 00:00:00
abstract::Progression and rupture of atherosclerotic plaques in coronary and carotid arteries are the key processes underlying myocardial infarctions and strokes. Biomechanical stress analyses to compute mechanical stresses in a plaque can potentially be used to assess plaque vulnerability. The stress analyses strongly rely on ...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.01.019
更新日期:2014-03-03 00:00:00
abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.007
更新日期:2011-01-04 00:00:00
abstract::Lower propulsive joint powers, particularly at the ankle, are often observed in older compared to young adults. Interventions to increase joint powers often require labs with motion capture and force treadmill technology. Translating these interventions out of the lab requires identifying portable measures that track ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109821
更新日期:2020-06-09 00:00:00
abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.05.034
更新日期:2018-07-25 00:00:00
abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.029
更新日期:2010-10-19 00:00:00
abstract::The damping mechanisms that are operational in the heel pad during the impact phase of locomotion have the important function to protect the musculo-skeletal system from injuries. How this is achieved is still not fully understood, as is for instance illustrated by the 'heel pad paradox', the observation that in vivo ...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.10.006
更新日期:2005-12-01 00:00:00