A wax barrier to simulate bone resorption for pre-clinical laboratory models of cemented total hip replacements.

Abstract:

:Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endosteal surface of the bone, prior to cementing of the femoral component. This approach was applied to six fresh frozen human cadaver femora and the resulting cement-bone morphology and micromotion following application of torsional loads were measured on a transverse section of each bone. The contact fraction between cement and bone for the wax barrier specimens (6.4±5.7%, range: 0.5-15%) was similar to that found in postmortem retrievals (10.5±10.3%, range: 0.4-32.5%). Micro-motions at the cement-bone interface for the wax barrier specimens (0.5±1.06 mm, range: 0.005-2.66) were similar, but on average larger than those found with postmortem retrievals (0.092±0.22 mm, range: 0.002-0.73). The use of a wax barrier coating technique could improve experimental pre-clinical tests because it produces a cement-bone interface similar to those of functioning cemented components obtained following in vivo service.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Cherukuri AR,Miller MA,Race A,Izant TH,Mann KA

doi

10.1016/j.jbiomech.2010.06.029

subject

Has Abstract

pub_date

2010-10-19 00:00:00

pages

2855-7

issue

14

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(10)00365-9

journal_volume

43

pub_type

杂志文章
  • Application of singular spectrum analysis to the smoothing of raw kinematic signals.

    abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.031

    authors: Alonso FJ,Castillo JM,Pintado P

    更新日期:2005-05-01 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Insufficient accuracy of the ultrasound-based determination of Achilles tendon cross-sectional area.

    abstract::The accurate assessment of the Achilles tendon cross-sectional area (CSA) is a crucial prerequisite to investigate tendon adaptation and to calculate the tendon Young׳s modulus. Besides magnetic resonance imaging (MRI), ultrasonography emerged as an alternative imaging technique. The purpose of the present study was t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.002

    authors: Bohm S,Mersmann F,Schroll A,Mäkitalo N,Arampatzis A

    更新日期:2016-09-06 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • Model-based inverse estimation for active contraction stresses of tongue muscles using 3D surface shape in speech production.

    abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.008

    authors: Koike N,Ii S,Yoshinaga T,Nozaki K,Wada S

    更新日期:2017-11-07 00:00:00

  • Experimental measurement and quantification of frictional contact between biological surfaces experiencing large deformation and slip.

    abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.006

    authors: Gratz KR,Sah RL

    更新日期:2008-01-01 00:00:00

  • Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints.

    abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.024

    authors: Drewniak EI,Jay GD,Fleming BC,Crisco JJ

    更新日期:2009-08-25 00:00:00

  • Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.

    abstract::The hemodynamic influence of vessel shape such as bifurcation angle is not fully understood with clinical and quantitative observations being equivocal. The aim of this study is to use computational modeling to study the hemodynamic effect of shape characteristics, in particular bifurcation angle (BA), for non-stented...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.038

    authors: Beier S,Ormiston J,Webster M,Cater J,Norris S,Medrano-Gracia P,Young A,Cowan B

    更新日期:2016-06-14 00:00:00

  • The effects of groove height and substrate stiffness on C. elegans locomotion.

    abstract::The physical environment surrounding an animal has a significant impact on its behavior. The nematode Caenorhabditis elegans (C. elegans) has proved to be an excellent choice for understanding the adaptability of organisms crawling on soft surfaces. In this work, we investigate the modulation of C. elegans' behavioral...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.02.015

    authors: Parida L,Ghosh UU,Padmanabhan V

    更新日期:2017-04-11 00:00:00

  • Displacement analysis of the temporomandibular condyle from magnetic resonance images.

    abstract::A technique was developed to investigate the condylar displacement of the human temporomandibular joint. Condylar displacement was analyzed from magnetic resonance images of the joint. Fourteen static images were obtained during incremental jaw closure. Landmarks were identified on the magnetic resonance images and re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90096-w

    authors: Chen J,Buckwalter K

    更新日期:1993-12-01 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Probabilistic finite element prediction of knee wear simulator mechanics.

    abstract::Computational models have recently been developed to replicate experimental conditions present in the Stanmore knee wear simulator. These finite element (FE) models, which provide a virtual platform to evaluate total knee replacement (TKR) mechanics, were validated through comparisons with experimental data for a spec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.029

    authors: Laz PJ,Pal S,Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2006-01-01 00:00:00

  • Computer simulation of blood flow in the human arm.

    abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90019-5

    authors: Balar SD,Rogge TR,Young DF

    更新日期:1989-01-01 00:00:00

  • Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site.

    abstract::In the context of reconciling the mechanical properties of trabecular bone measured from in vitro mechanical testing with the true in situ behavior, recent attention has focused on the "side-artifact" which results from interruption of the trabecular network along the sides of machined specimens. The objective of this...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.008

    authors: Bevill G,Easley SK,Keaveny TM

    更新日期:2007-01-01 00:00:00

  • Gait variability magnitude but not structure is altered in essential tremor.

    abstract::Essential tremor (ET) is a common tremor disorder affecting postural/action tremor of the upper extremities and midline. Recent research revealed a cerebellar-like deficit during tandem gait in persons with ET, though spatiotemporal variability during normal gait in ET has been relatively ignored. The first purpose of...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.07.039

    authors: Roemmich RT,Zeilman PR,Vaillancourt DE,Okun MS,Hass CJ

    更新日期:2013-10-18 00:00:00

  • Blood flow patterns and pressure loss in the ascending aorta: A comparative study on physiological and aneurysmal conditions.

    abstract::An aortic aneurysm is defined as a balloon-shaped bulging of all three histologic components of the aortic vessel walls (intima, media and adventitia). This dilation results from vessel weakening owing to remodeling, i.e. due to cystic degeneration of the Tunica media (Marfan), progression of atherosclerosis or presen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.033

    authors: Gülan U,Calen C,Duru F,Holzner M

    更新日期:2018-07-25 00:00:00

  • Skewness angle of interfibrillar proteoglycans increases with applied load on mitral valve chordae tendineae.

    abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.011

    authors: Liao J,Vesely I

    更新日期:2007-01-01 00:00:00

  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00

  • Fatigue creep damage at the cement-bone interface: an experimental and a micro-mechanical finite element study.

    abstract::The goal of this study was to quantify the micromechanics of the cement-bone interface under tensile fatigue loading using finite element analysis (FEA) and to understand the underlying mechanisms that play a role in the fatigue behavior of this interface. Laboratory cement-bone specimens were subjected to a tensile f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.014

    authors: Waanders D,Janssen D,Miller MA,Mann KA,Verdonschot N

    更新日期:2009-11-13 00:00:00

  • Exploring the regional disc bulge response of the cervical porcine intervertebral disc under varying loads and posture.

    abstract::Nerve compression due to intervertebral disc (IVD) bulging is a known mechanism for low back pain and typically occurs in the posterior region of the disc. Most in vitro studies are limited in the ability to quantify the magnitude of bulging on the posterior aspect of the disc due to the boney structures that occlude ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109713

    authors: Fewster KM,Noguchi M,Gooyers CE,Wong A,Callaghan JP

    更新日期:2020-05-07 00:00:00

  • Study of cradle and pendulum motion for applications to health care.

    abstract::Hammocks and cradles have long been appreciated, but in a very limited way. Aside from being emotionally soothing the devices affect the skin and all deep body components. While structurally simple they are functionally quite sophisticated and could very well affect the pattern of health care across the board--acute, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90089-7

    authors: Frisina W

    更新日期:1984-01-01 00:00:00

  • Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

    abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109603

    authors: Breen A,Breen A

    更新日期:2020-03-26 00:00:00

  • Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA).

    abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.010

    authors: Norman TL,Shultz T,Noble G,Gruen TA,Blaha JD

    更新日期:2013-03-15 00:00:00

  • A mechanical approach to the longitudinal dispersion of gas flowing in human airways.

    abstract::The aim of this work is to contribute to elucidating the mechanism underlying gas mixing in the human pulmonary airways. For this purpose, a particular attempt is made to analyse the fluid mechanical aspects of gaseous dispersion using bolus response methods. The experiments were performed on five normal subjects by i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90295-7

    authors: Ben Jebria A

    更新日期:1985-01-01 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Biomechanists can revolutionize the STEM pipeline by engaging youth athletes in sports-science based STEM outreach.

    abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109511

    authors: Drazan JF

    更新日期:2020-01-23 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA