In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

Abstract:

:Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have either relied on wear simulations, computational modeling, or in vitro measurements to quantify sliding distance and cross-shear, in vivo subject-specific sliding distance and cross-shear after bi-cruciate retaining (BCR) TKA has not been previously reported. The objective of this study was to quantify the 6°-of-freedom (6DOF) in vivo kinematics, sliding distance, and cross-shear in BCR TKA patients during gait. Twenty-nine unilateral BCR TKA patients performed level walking on a treadmill under dual fluoroscopic imaging system (DFIS) surveillance. Cumulative normalized sliding distances between the lateral and medial compartments did not change significantly (p > 0.05) during the gait cycle. Although the total normalized sliding distance was similar between the lateral and medial compartments, the cross-shear at the lateral compartment differed significantly from that at the medial compartment (p < 0.001). Significant differences in the relative length positions of the peak sliding distance and cross-shear were found between the lateral and medial bearing components. The flexion-extension motion of the reconstructed knee was more associated with the linear displacements (anterior-posterior, R2 = 0.6; lateral-medial, R2 = 0.8, proximal-distal, R2 = 0.7) than the angular displacement (varus-valgus, R2 = 0.18; internal-external rotation, R2 = 0.28). Despite some differences in peak sliding distance and cross-shear positons, our results suggest similar articular contact patterns between the lateral and medial compartments in BCR TKA patients during gait. The data could provide insights into understanding the potential wear patterns in BCR TKAs.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Arauz P,Peng Y,An S,Kwon YM

doi

10.1016/j.jbiomech.2018.06.009

subject

Has Abstract

pub_date

2018-08-22 00:00:00

pages

8-15

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30438-X

journal_volume

77

pub_type

杂志文章
  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • No consensus on causality of spine postures or physical exposure and low back pain: A systematic review of systematic reviews.

    abstract::Specific spinal postures and physical activities have been linked to low back pain (LBP) but previous reviews have produced contrasting outcomes. This umbrella review examined (1) what relationship, if any, is evident between specific spinal postures or physical activities and LBP; (2) the quality of existing systemat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2019.08.006

    authors: Swain CTV,Pan F,Owen PJ,Schmidt H,Belavy DL

    更新日期:2020-03-26 00:00:00

  • Crack growth resistance in cortical bone: concept of microcrack toughening.

    abstract::The role of microcracking in cortical bone as a toughening mechanism has been investigated in conjunction with the variation in fracture toughness with crack length. Fracture toughness tests were conducted on miniaturised compact tension specimens made from human and bovine cortical bone and the resultant microstructu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00029-8

    authors: Vashishth D,Behiri JC,Bonfield W

    更新日期:1997-08-01 00:00:00

  • Propulsive joint powers track with sensor-derived angular velocity: A potential tool for lab-less gait retraining.

    abstract::Lower propulsive joint powers, particularly at the ankle, are often observed in older compared to young adults. Interventions to increase joint powers often require labs with motion capture and force treadmill technology. Translating these interventions out of the lab requires identifying portable measures that track ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109821

    authors: Hafer JF,Zernicke RF

    更新日期:2020-06-09 00:00:00

  • Micropipette aspiration method for characterizing biological materials with surface energy.

    abstract::Many soft biological tissues possess a considerable surface stress, which plays a significant role in their biophysical functions, but most previous methods for characterizing their mechanical properties have neglected the effects of surface stress. In this work, we investigate the micropipette aspiration method to me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.020

    authors: Ding Y,Wang GF,Feng XQ,Yu SW

    更新日期:2018-10-26 00:00:00

  • Equine subchondral bone failure threshold under impact compression applied through articular cartilage.

    abstract::Subchondral bone microdamage due to high-impact loading is a key factor leading to post-traumatic knee osteoarthritis. A quantified assessment of the mechanical characteristics of subchondral bone at the tissue-level is essential to study the mechanism of impact-induced microdamage. We combined mechanical impact testi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.016

    authors: Malekipour F,Oetomo D,Lee PV

    更新日期:2016-07-05 00:00:00

  • Two strategies of transferring from sit-to-stand; the activation of monoarticular and biarticular muscles.

    abstract::In this study, two different strategies of rising from a chair were compared, using integrated biomechanical and electromyographic analyses. Nine healthy subjects were instructed to rise using two different strategies: natural sit-to-stand transfer (NSTS) and a sit-to-stand transfer with full flexion of the trunk (FST...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90039-6

    authors: Doorenbosch CA,Harlaar J,Roebroeck ME,Lankhorst GJ

    更新日期:1994-11-01 00:00:00

  • In vivo measurement of ACL length and relative strain during walking.

    abstract::Although numerous studies have addressed the effects of ACL injury and reconstruction on knee joint motion, there is currently little data available describing in vivo ACL strain during activities of daily living. Data describing in vivo ACL strain during activities such as gait is critical to understanding the biomec...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.031

    authors: Taylor KA,Cutcliffe HC,Queen RM,Utturkar GM,Spritzer CE,Garrett WE,DeFrate LE

    更新日期:2013-02-01 00:00:00

  • The nature of the stabilizing functions of skeletal muscles.

    abstract::The paper defines the term coordination interval (CI), suggesting that it should replace the term electromechanical delay (EMD), if this parameter is determined in vivo for a muscle functioning in a biomechanical system with considerable mobility, but not in a kinematic pair with one degree of rotational freedom (DOF)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90211-9

    authors: Kornecki S,Zschorlich V

    更新日期:1994-02-01 00:00:00

  • In vitro analysis of localized aneurysm rupture.

    abstract::In this study, bulge inflation tests were used to characterize the failure response of 15 layers of human ascending thoracic aortic aneurysms (ATAA). Full field displacement data were collected during each of the mechanical tests using a digital image stereo-correlation (DIS-C) system. Using the collected displacement...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.012

    authors: Romo A,Badel P,Duprey A,Favre JP,Avril S

    更新日期:2014-02-07 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Compression-induced damage and internal tissue strains are related.

    abstract::Prolonged mechanical loading of soft tissues adjacent to bony prominences can lead to degeneration of muscle tissue, resulting in a condition termed pressure-related deep tissue injury. This type of deep pressure ulcers can develop into a severe wound, associated with problematic healing and a variable prognosis. Limi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.016

    authors: Ceelen KK,Stekelenburg A,Loerakker S,Strijkers GJ,Bader DL,Nicolay K,Baaijens FP,Oomens CW

    更新日期:2008-12-05 00:00:00

  • Propulsion biomechanics do not differ between athletic and nonathletic manual wheelchair users in their daily wheelchairs.

    abstract::The purpose of this study was to investigate whether athletic and nonathletic manual wheelchair users (MWU) display differences in kinetic and kinematic variables during daily wheelchair propulsion. Thirty-nine manual wheelchair users (athletic n = 25; nonathletic n = 14) propelled their own daily living wheelchair on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109725

    authors: Briley SJ,Vegter RJK,Tolfrey VL,Mason BS

    更新日期:2020-05-07 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • Segment inertial parameter evaluation in two anthropometric models by application of a dynamic linked segment model.

    abstract::The estimation of segment inertial parameters (SIPs) is an important source of error in inverse dynamic analysis. In most individual cases SIPs are derived from extrapolation of known SIPs of a certain population through regression equations (proportional models). Another well-known method is the use of mathematical a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00086-0

    authors: Kingma I,Toussaint HM,De Looze MP,Van Dieen JH

    更新日期:1996-05-01 00:00:00

  • Ground reaction forces are more sensitive gait measures than temporal parameters in rodents following rotator cuff injury.

    abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.027

    authors: Pardes AM,Freedman BR,Soslowsky LJ

    更新日期:2016-02-08 00:00:00

  • Changes in the mechanical properties of the trunk in low back pain may be associated with recurrence.

    abstract::Exercise is one of the few effective treatments for LBP. Although exercise is often based on the premise of reduced spinal stiffness, trunk muscle adaptation may increase stiffness. This study developed and validated a method to assess trunk stiffness and damping, and tested these parameters in 14 people with recurrin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.001

    authors: Hodges P,van den Hoorn W,Dawson A,Cholewicki J

    更新日期:2009-01-05 00:00:00

  • In vivo porcine left atrial wall stress: Effect of ventricular tachypacing on spatial and temporal stress distribution.

    abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.003

    authors: Di Martino ES,Bellini C,Schwartzman DS

    更新日期:2011-11-10 00:00:00

  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • A comparison of reflection and transmission ultrasonic techniques for measurement of cancellous bone elasticity.

    abstract::A reflection ultrasonic technique, which offers several advantages over transmission ultrasonic techniques, has been described for elastic property measurement of bone. Ultrasonic velocities from specimens of cancellous bone were compared using a reflection ultrasound technique and the more traditional transmission ul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90061-2

    authors: Ashman RB,Antich PP,Gonzales J,Anderson JA,Rho JY

    更新日期:1994-09-01 00:00:00

  • Dynamic hydrostatic pressure enhances differentially the chondrogenesis of meniscal cells from the inner and outer zone.

    abstract::This study analyses the influence of dynamic hydrostatic pressure on chondrogenesis of human meniscus-derived fibrochondrocytes and explores the differences in chondrogenic differentiation under loading conditions between cells derived from the avascular inner zone and vascularized outer region of the meniscus. Aggreg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.003

    authors: Zellner J,Mueller M,Xin Y,Krutsch W,Brandl A,Kujat R,Nerlich M,Angele P

    更新日期:2015-06-01 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Enhanced global mathematical model for studying cerebral venous blood flow.

    abstract::Here we extend the global, closed-loop, mathematical model for the cardiovascular system in Müller and Toro (2014) to account for fundamental mechanisms affecting cerebral venous haemodynamics: the interaction between intracranial pressure and cerebral vasculature and the Starling-resistor like behaviour of intracrani...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.005

    authors: Müller LO,Toro EF

    更新日期:2014-10-17 00:00:00

  • Effective modulus of the human intervertebral disc and its effect on vertebral bone stress.

    abstract::The mechanism of vertebral wedge fractures remains unclear and may relate to typical variations in the mechanical behavior of the intervertebral disc. To gain insight, we tested 16 individual whole discs (between levels T8 and L5) from nine cadavers (mean±SD: 66±16 years), loaded in compression at different rates (0.0...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.045

    authors: Yang H,Jekir MG,Davis MW,Keaveny TM

    更新日期:2016-05-03 00:00:00

  • Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty.

    abstract::Squeaking is reported for ceramic-on-ceramic hip arthroplasty, and risk factors leading to this phenomenon have been investigated empirically in the past, this way giving hints to when this phenomenon occurs. The aim of this study is to present an experimentally validated explanation for the dynamical mechanism underl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.025

    authors: Weiss C,Hothan A,Huber G,Morlock MM,Hoffmann NP

    更新日期:2012-01-10 00:00:00

  • Effects of different initial foot positions on kinematics, muscle activation patterns, and postural control during a sit-to-stand in younger and older adults.

    abstract:BACKGROUND:Performing a sit-to-stand (STS) can be a challenging task for older adults because of age-related declines in neuromuscular strength and coordination. We investigated the effects of different initial foot positions (IFPs) on kinematics, muscle activation patterns, and balance control during a STS in younger ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110251

    authors: Jeon W,Hsiao HY,Griffin L

    更新日期:2021-01-13 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Velocities and stress levels of axisymmetric, azimuthal flow within the toroidal rotary seal of the IBM 2997 continuous flow cell separator and the implications.

    abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90163-6

    authors: Harvey CB,O'Rear EA

    更新日期:1986-01-01 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00