Segment inertial parameter evaluation in two anthropometric models by application of a dynamic linked segment model.

Abstract:

:The estimation of segment inertial parameters (SIPs) is an important source of error in inverse dynamic analysis. In most individual cases SIPs are derived from extrapolation of known SIPs of a certain population through regression equations (proportional models). Another well-known method is the use of mathematical approximation of the shape of human body segments combined with estimations of segment densities (geometric models). In the current study five males and five females performed four different lifting movements in the sagittal plane. A full body linked segment model was applied twice to the same data set, once using a proportional and once using a geometric anthropometric model. As a full body linked segment model is an overdetermined system of equations, four equations could be formed to test the summed effect of SIP errors on the inverse dynamic analysis. The overall performance in terms of coefficients of correlation was better for the geometric model as compared to the proportional model. When a back lifting movement was performed, the equations indicated systematic errors in the proportional model. However, when a leg lifting movement was performed, the equations indicated systematic errors in the geometric model. Therefore, analyzing only one kind of movement does not suffice to draw conclusions with respect to the reliability of an anthropometric model.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kingma I,Toussaint HM,De Looze MP,Van Dieen JH

doi

10.1016/0021-9290(95)00086-0

subject

Has Abstract

pub_date

1996-05-01 00:00:00

pages

693-704

issue

5

eissn

0021-9290

issn

1873-2380

pii

0021929095000860

journal_volume

29

pub_type

杂志文章
  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • In vivo biomechanical behavior of the human heel pad during the stance phase of gait.

    abstract::A technique is introduced for simultaneous measurements of the heel pad tissue deformation and the heel-ground contact stresses developing during the stance phase of gait. Subjects walked upon a gait platform integrating the contact pressure display optical method for plantar pressure measurements and a digital radiog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00143-9

    authors: Gefen A,Megido-Ravid M,Itzchak Y

    更新日期:2001-12-01 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Development of an RSA calibration system with improved accuracy and precision.

    abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.012

    authors: Cai R,Yuan X,Rorabeck C,Bourne RB,Holdsworth DW

    更新日期:2008-01-01 00:00:00

  • Intravoxel bone micromechanics for microCT-based finite element simulations.

    abstract::While micro-FE simulations have become a standard tool in computational biomechanics, the choice of appropriate material properties is still a relevant topic, typically involving empirical grey value-to-elastic modulus relations. We here derive the voxel-specific volume fractions of mineral, collagen, and water, from ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.036

    authors: Blanchard R,Dejaco A,Bongaers E,Hellmich C

    更新日期:2013-10-18 00:00:00

  • The development of an improved physical surrogate model of the human spinal cord--tension and transverse compression.

    abstract::To prevent spinal cord injury, optimize treatments for it, and better understand spinal cord pathologies such as spondylotic myelopathy, the interaction between the spinal column and the spinal cord during injury and pathology must be understood. The spinal cord is a complex and very soft tissue that changes propertie...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.036

    authors: Kroeker SG,Morley PL,Jones CF,Bilston LE,Cripton PA

    更新日期:2009-05-11 00:00:00

  • No consensus on causality of spine postures or physical exposure and low back pain: A systematic review of systematic reviews.

    abstract::Specific spinal postures and physical activities have been linked to low back pain (LBP) but previous reviews have produced contrasting outcomes. This umbrella review examined (1) what relationship, if any, is evident between specific spinal postures or physical activities and LBP; (2) the quality of existing systemat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2019.08.006

    authors: Swain CTV,Pan F,Owen PJ,Schmidt H,Belavy DL

    更新日期:2020-03-26 00:00:00

  • Modeling the mechanical properties of liver fibrosis in rats.

    abstract::The progression of liver fibrosis changes the biomechanical properties of liver tissue. This study characterized and compared different liver fibrosis stages in rats in terms of viscoelasticity. Three viscoelastic models, the Voigt, Maxwell, and Zener models, were applied to experimental data from rheometer tests and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.013

    authors: Zhu Y,Chen X,Zhang X,Chen S,Shen Y,Song L

    更新日期:2016-06-14 00:00:00

  • T2 relaxation time measurements in tibiotalar cartilage after barefoot running and its relationship to ankle biomechanics.

    abstract::The influence of ankle kinematics and plantar pressure from mid-range barefoot running on T2 relaxation times of tibiotalar cartilage is unknown. This study aimed to quantitatively evaluate the T2 relaxation time of tibiotalar cartilage and ankle biomechanics following 5 km barefoot running. Twenty healthy runners (wh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.046

    authors: Kyung Kim H,Fernandez J,Logan C,Tarr GP,Doyle A,Mirjalili SA

    更新日期:2019-06-11 00:00:00

  • The flexural rigidity of the aortic valve leaflet in the commissural region.

    abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.026

    authors: Mirnajafi A,Raymer JM,McClure LR,Sacks MS

    更新日期:2006-01-01 00:00:00

  • Dynamic mechanical response of bovine gray matter and white matter brain tissues under compression.

    abstract::Dynamic responses of brain tissues are needed for predicting traumatic brain injury (TBI). We modified a dynamic experimental technique for characterizing high strain-rate mechanical behavior of brain tissues. Using the setup, the gray and white matters from bovine brains were characterized under compression to large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.023

    authors: Pervin F,Chen WW

    更新日期:2009-04-16 00:00:00

  • A new instrumentation system for training rowers.

    abstract::A dry-land rowing system was developed to provide the coach and/or athlete with quantitative information about the athlete's kinetics and kinematics while the athlete trains. This system consists of a Concept II rowing ergometer instrumented with a force transducer and potentiometer, four electrogoniometers attached t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00139-6

    authors: Hawkins D

    更新日期:2000-02-01 00:00:00

  • Mechanical properties vary for different regions of the finger extensor apparatus.

    abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.035

    authors: Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

    更新日期:2014-09-22 00:00:00

  • Instantaneous velocity estimation for the four swimming strokes using a 3-axis accelerometer: Validation on paralympic athletes.

    abstract::Inertial measurement unit systems (IMU) are increasingly used in sports. However, no algorithm evaluating the instantaneous swimming velocity has been validated on the four swimming strokes, or on dive start. Our objective is to develop and validate a new method to measure instantaneous swimming velocity on athletes p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110261

    authors: Clément J,Charbonneau M,Thompson M

    更新日期:2021-01-19 00:00:00

  • Wrist tendon moment arms: Quantification by imaging and experimental techniques.

    abstract::Subject-specific musculoskeletal models require accurate values of muscle moment arms. The aim of this study was to compare moment arms of wrist tendons obtained from non-invasive magnetic resonance imaging (MRI) to those obtained from an in vitro experimental approach. MRI was performed on ten upper limb cadaveric sp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.024

    authors: Garland AK,Shah DS,Kedgley AE

    更新日期:2018-02-08 00:00:00

  • Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

    abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.025

    authors: Kim DG,Shertok D,Ching Tee B,Yeni YN

    更新日期:2011-06-03 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • Hip contact forces and gait patterns from routine activities.

    abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00040-9

    authors: Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

    更新日期:2001-07-01 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Validation of a novel method for quantifying and comparing regional ACL elongations during uniaxial tensile loading.

    abstract::Given the complex three-dimensional (3D) knee joint loading associated with anterior cruciate ligament (ACL) injuries, accurate site- and bundle-specific strain measurements are critical. The purpose of this study was to quantify tensile load-induced migrations of radio-opaque markers injected directly into the ACL, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.016

    authors: Beaulieu ML,Haladik JA,Bey MJ,McLean SG

    更新日期:2012-10-11 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • A study of the viability of obtaining a generic animation of the foot while walking for the virtual testing of footwear using dorsal pressures.

    abstract::Establishing the appropriate pressure exerted by the shoe upper over the foot surface is fundamental for the design of specific footwear, although measuring the dorsal pressures can also provide important additional information. In previous works, a virtual simulator to perform studies of comfort and functionality in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.054

    authors: Rupérez MJ,Alemany S,Monserrat C,Olaso J,Alcañíz M,González JC

    更新日期:2009-09-18 00:00:00

  • Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.

    abstract::The hemodynamic influence of vessel shape such as bifurcation angle is not fully understood with clinical and quantitative observations being equivocal. The aim of this study is to use computational modeling to study the hemodynamic effect of shape characteristics, in particular bifurcation angle (BA), for non-stented...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.038

    authors: Beier S,Ormiston J,Webster M,Cater J,Norris S,Medrano-Gracia P,Young A,Cowan B

    更新日期:2016-06-14 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • Exploring the regional disc bulge response of the cervical porcine intervertebral disc under varying loads and posture.

    abstract::Nerve compression due to intervertebral disc (IVD) bulging is a known mechanism for low back pain and typically occurs in the posterior region of the disc. Most in vitro studies are limited in the ability to quantify the magnitude of bulging on the posterior aspect of the disc due to the boney structures that occlude ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109713

    authors: Fewster KM,Noguchi M,Gooyers CE,Wong A,Callaghan JP

    更新日期:2020-05-07 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • A parametric model for studying the aorta hemodynamics by means of the computational fluid dynamics.

    abstract::Perturbed aorta hemodynamics, as for the carotid and the coronary artery, has been identified as potential predicting factor for cardiovascular diseases. In this study, we propose a parametric study based on the computational fluid dynamics with the aim of providing information regarding aortic disease. In particular,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109691

    authors: Cilla M,Casales M,Peña E,Martínez MA,Malvè M

    更新日期:2020-04-16 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00