Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

Abstract:

:Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite element analysis. It was assumed that braided stents were manufactured using SMPU fibers. The mechanical behavior of SMPU fibers was modeled using a constitutive equation describing their one-dimensional thermal-induced shape memory behavior. Then, the braided stents were analyzed to investigate their mechanical behavior using finite element analysis software, in which the constitutive equation was implemented through a user material subroutine. The diameter of the SMPU fibers and braiding angle were chosen as the design parameters and their values were adjusted to ensure that the mechanical properties of the braided polymer stents match those of metallic stents. Finally, the deployment process of the braided stents inside narrowed vessels was simulated, showing that the SMPU stents can be comfortably implanted while minimizing the overpressure onto the vessel walls, due to their thermo-responsive shape memory behavior.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kim JH,Kang TJ,Yu WR

doi

10.1016/j.jbiomech.2009.10.032

subject

Has Abstract

pub_date

2010-03-03 00:00:00

pages

632-43

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00606-X

journal_volume

43

pub_type

杂志文章
  • The effects of groove height and substrate stiffness on C. elegans locomotion.

    abstract::The physical environment surrounding an animal has a significant impact on its behavior. The nematode Caenorhabditis elegans (C. elegans) has proved to be an excellent choice for understanding the adaptability of organisms crawling on soft surfaces. In this work, we investigate the modulation of C. elegans' behavioral...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.02.015

    authors: Parida L,Ghosh UU,Padmanabhan V

    更新日期:2017-04-11 00:00:00

  • The consistency of maximum running speed measurements in humans using a feedback-controlled treadmill, and a comparison with maximum attainable speed during overground locomotion.

    abstract::Consistent measurement of maximum running speed overground is problematic due to the difficulty in precise, continual measurement of speed, and the substantial workload in accelerating the body promoting the onset of fatigue. Treadmills remove the requirement for acceleration which enables more repeats. They also allo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.024

    authors: Bowtell MV,Tan H,Wilson AM

    更新日期:2009-11-13 00:00:00

  • Two strategies of transferring from sit-to-stand; the activation of monoarticular and biarticular muscles.

    abstract::In this study, two different strategies of rising from a chair were compared, using integrated biomechanical and electromyographic analyses. Nine healthy subjects were instructed to rise using two different strategies: natural sit-to-stand transfer (NSTS) and a sit-to-stand transfer with full flexion of the trunk (FST...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90039-6

    authors: Doorenbosch CA,Harlaar J,Roebroeck ME,Lankhorst GJ

    更新日期:1994-11-01 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • Take-off analysis of the Olympic ski jumping competition (HS-106m).

    abstract::The take-off phase (approximately 6m) of the jumps of all athletes participating in the individual HS-106m hill ski jumping competition at the Torino Olympics was filmed with two high-speed cameras. The high altitude of the Pragelato ski jumping venue (1600m) and slight tail wind in the final jumping round were expect...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.026

    authors: Virmavirta M,Isolehto J,Komi P,Schwameder H,Pigozzi F,Massazza G

    更新日期:2009-05-29 00:00:00

  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Mathematical modeling of the stress strain-strain rate behavior of bone using the Ramberg-Osgood equation.

    abstract::The Ramberg-Osgood equation is used to model the viscoplastic properties of compact bone. Because of the exponential nature of this equation a special optimization technique is used to curve fitting. Results are presented for the application of this equation to three sets of strain rate dependent stress-strain curves ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90076-3

    authors: Hight TK,Brandeau JF

    更新日期:1983-01-01 00:00:00

  • A model of surfactant-induced surface tension effects on the parenchymal tethering of pulmonary airways.

    abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.031

    authors: Fujioka H,Halpern D,Gaver DP 3rd

    更新日期:2013-01-18 00:00:00

  • The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading.

    abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.061

    authors: Barone WR,Amini R,Maiti S,Moalli PA,Abramowitch SD

    更新日期:2015-06-25 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Effects of lumbo-pelvic rhythm on trunk muscle forces and disc loads during forward flexion: A combined musculoskeletal and finite element simulation study.

    abstract::Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.009

    authors: Liu T,Khalaf K,Adeeb S,El-Rich M

    更新日期:2019-01-03 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00

  • Hysteresis measurements in intact human tendon.

    abstract::Mechanical hysteresis in tendons has traditionally been quantified from tensile testing of isolated specimens. Limitations associated with tendon displacement measurement and clamping, and uncertainties as to whether in vitro material represents intact tendon function necessitate measuring hysteresis under in vivo con...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00130-5

    authors: Maganaris CN,Paul JP

    更新日期:2000-12-01 00:00:00

  • Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.

    abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.140

    authors: Pawaskar SS,Grosland NM,Ingham E,Fisher J,Jin Z

    更新日期:2011-05-17 00:00:00

  • Experimental evaluation of local wave speed in the presence of reflected waves.

    abstract::Wave speed (also called pulse wave velocity) is the speed by which disturbance travels along the medium and it depends on the mechanical and geometrical properties of the vessel and on the density of the blood. Wave speed is a parameter of clinical relevance because it is an indicator of arterial stiffness and cardiov...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.007

    authors: Borlotti A,Li Y,Parker KH,Khir AW

    更新日期:2014-01-03 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Shear strength and toughness of trabecular bone are more sensitive to density than damage.

    abstract::Microdamage occurs in trabecular bone under normal loading, which impairs the mechanical properties. Architectural degradation associated with osteoporosis increases damage susceptibility, resulting in a cumulative negative effect on the mechanical properties. Treatments for osteoporosis could be targeted toward incre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.002

    authors: Garrison JG,Gargac JA,Niebur GL

    更新日期:2011-11-10 00:00:00

  • Nanomechanical properties of individual chondrocytes and their developing growth factor-stimulated pericellular matrix.

    abstract::The nanomechanical properties of individual cartilage cells (chondrocytes) and their aggrecan and collagen-rich pericellular matrix (PCM) were measured via atomic force microscope nanoindentation using probe tips of two length scales (nanosized and micron-sized). The properties of cells freshly isolated from cartilage...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.04.004

    authors: Ng L,Hung HH,Sprunt A,Chubinskaya S,Ortiz C,Grodzinsky A

    更新日期:2007-01-01 00:00:00

  • Modeling methodology for defining a priori the hydrodynamics of a dynamic suspension bioreactor. Application to human induced pluripotent stem cell culture.

    abstract::Three-dimensional dynamic suspension is becoming an effective cell culture method for a wide range of bioprocesses, with an increasing number of bioreactors proposed for this purpose. The complex hydrodynamics establishing within these devices affects bioprocess outcomes and efficiency, and usually expensive in vitro ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.021

    authors: Isu G,Morbiducci U,De Nisco G,Kropp C,Marsano A,Deriu MA,Zweigerdt R,Audenino A,Massai D

    更新日期:2019-09-20 00:00:00

  • High-resolution spatial mapping of shear properties in cartilage.

    abstract::Structural properties of articular cartilage such as proteoglycan content, collagen content and collagen alignment are known to vary over length scales as small as a few microns (Bullough and Goodfellow, 1968; Bi et al., 2006). Characterizing the resulting variation in mechanical properties is critical for understandi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.012

    authors: Buckley MR,Bergou AJ,Fouchard J,Bonassar LJ,Cohen I

    更新日期:2010-03-03 00:00:00

  • Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis.

    abstract::To evaluate the efficacy of implanting a tilting disc aortic valve prosthesis in an angulated (wedged) supra-annular position, an in vitro experimental study was performed. The aortic valve prosthesis was mounted in an axi-symmetric valve chamber in a wedged position and incorporated in a mock circulatory system. Meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90150-8

    authors: Chandran KB,Fatemi R,Hiratzka LF,Harris C

    更新日期:1986-01-01 00:00:00

  • Investigation of the kinetics of anaerobic metabolism by analysis of the performance of elite sprinters.

    abstract::The principal motivation for the present work was the study of the kinetics of anaerobic metabolism. A new mathematical model of the bioenergetics of sprinting, incorporating a three-equation representation of anaerobic metabolism, is developed. Results computed using the model are compared with measured data from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00035-x

    authors: Ward-Smith AJ,Radford PF

    更新日期:2000-08-01 00:00:00

  • Comparison of acoustic characteristics predicted by Biot's theory and the modified Biot-Attenborough model in cancellous bone.

    abstract::Biot's theory and the modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and on porosity in cancellous bone. The phase velocities and the attenuation coefficients predicted by both theories are compared with the experimental data of bovine cancellous ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.004

    authors: Lee KI,Yoon SW

    更新日期:2006-01-01 00:00:00

  • Effect of foods on selected dynamic parameters of mandibular elevator muscles during symmetric incisal biting.

    abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109800

    authors: Stróżyk P,Jacek B

    更新日期:2020-06-09 00:00:00

  • An in vitro model for the pathological degradation of articular cartilage in osteoarthritis.

    abstract::The objective of this study was to develop an in vitro cartilage degradation model that emulates the damage seen in early-stage osteoarthritis. To this end, cartilage explants were collagenase-treated to induce enzymatic degradation of collagen fibers and proteoglycans at the articular surface. To assess changes in me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.050

    authors: Grenier S,Bhargava MM,Torzilli PA

    更新日期:2014-02-07 00:00:00

  • Evaluation of the superficial characteristics of articular cartilage using evanescent waves in the friction tests with intermittent sliding and loading.

    abstract::Articular cartilage plays an important role in the lubrication of synovial joints because of its peculiar characteristics. In this work, the frictional and superficial characteristics of articular cartilage were evaluated simultaneously during intermittent sliding and loading. The apparatus used for the analysis of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.015

    authors: Naka MH,Hattori K,Ikeuchi K

    更新日期:2006-01-01 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Toward quantification of athetotic movements by frequency spectrum analysis.

    abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90046-6

    authors: Niku S,Henderson JM

    更新日期:1985-01-01 00:00:00