Abstract:
:Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting surface. While previous research has explored attachment mechanisms of the tarsi, little is known about the relation between the mechanical function and the structural design and material properties of the ant. This study focuses on the neck--the single joint that withstands the full load capacity. We combine mechanical testing, computed tomography (CT), scanning electron microscopy (SEM), and computational modeling to better understand the mechanical structure-function relation of the neck joint of the ant species Formica exsectoides (Allegheny mound ant). Our mechanical testing results show that the soft tissue forming the neck joint of F. exsectoides exhibits an elastic modulus of 230±140 MPa and can withstand ~5000 times the ant's weight. We developed a 3-dimensional (3D) model of the structural components of the neck joint for simulation of mechanical behavior. Finite element (FE) simulations reveal the neck-to-head transition where the soft membrane material meets the hard exoskeleton as the critical point for failure of the neck joint, which is consistent with our experiments. Our results further indicate that the neck joint structure exhibits anisotropic mechanical behavior with the highest stiffness occurring when the load path is aligned with the axis of the neck.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Nguyen V,Lilly B,Castro Cdoi
10.1016/j.jbiomech.2013.10.053subject
Has Abstractpub_date
2014-01-22 00:00:00pages
497-504issue
2eissn
0021-9290issn
1873-2380pii
S0021-9290(13)00545-9journal_volume
47pub_type
杂志文章abstract::Following active muscle lengthening, steady-state isometric force is elevated compared with an isometric contraction without prior lengthening for the same muscle length and activation level. This property of muscle contraction is known as residual force enhancement (RFE). Here, we aimed to determine whether neural fa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.019
更新日期:2018-09-10 00:00:00
abstract::In this review of patellofemoral joint forces as they might apply to implant design, methodologies for estimating forces on the patella and estimates of the forces, as reported in the literature, are summarized. Two methodologies exist for studying joint loads; one that measures kinematics in-vivo and uses analysis to...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2008.04.039
更新日期:2008-08-07 00:00:00
abstract::Nonconformity between the polyethylene liner and the metal shell may exist in modular acetabular components by design, due to manufacturing tolerances, or from locking mechanisms that attach the polyethylene liner to the metal shell. Relative motion at the liner/shell interface has been associated with backside wear, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00030-x
更新日期:1998-05-01 00:00:00
abstract::When running, energy is lost during stance to redirect the center of mass of the body (COM) from downwards to upwards. The present study uses a collision-based approach to analyze how these energy losses change with slope and speed. Therefore, we evaluate separately the average collision angle, i.e. the angle of devia...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.024
更新日期:2019-01-23 00:00:00
abstract::Implants of microporous β-tricalcium phosphate (β-TCP) were developed for primarily stable supply of bone defects. A consistent stability over the healing period should be retained in sheep. β-TCP cylindrical shaped implants, with 7 mm diameter, 25 mm length, medium pore diameter 5 μm and 40% porosity were developed. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.040
更新日期:2015-04-13 00:00:00
abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00038-3
更新日期:1996-10-01 00:00:00
abstract::Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogene...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.030
更新日期:2015-04-13 00:00:00
abstract::Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Efficient computer models present an effective way of evaluating these characteristics. Predicted contact stress and area due to articulations at the tibio-femoral and patello-femoral interfaces indicate potenti...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.02.046
更新日期:2005-02-01 00:00:00
abstract::A method is presented for quantitative determination of skin movement over the underlying skeletal structures during normal locomotion of the horse. The principle of the method is simultaneous visualization of the position of the skin and the underlying bony structures, by marking the bones with implanted light-emitti...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90138-7
更新日期:1986-01-01 00:00:00
abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.040
更新日期:2014-11-28 00:00:00
abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2019.06.009
更新日期:2019-08-27 00:00:00
abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.11.003
更新日期:2009-02-09 00:00:00
abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.026
更新日期:2006-01-01 00:00:00
abstract::The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions du...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.017
更新日期:2016-07-05 00:00:00
abstract::In Part II of this two paper sequence, pulsatile flow development past a tilting disc valve in a model human aorta has been studied using quantitative laser Doppler techniques. The valve was mounted in three different orientations with respect to the aortic root in this study. Under pulsatile flow, the region of flow ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90052-1
更新日期:1985-01-01 00:00:00
abstract::As plaque develops in arteries two types of remodeling can occur; positive and negative remodeling. Positive remodeling is an outward compensatory remodeling in which the arterial wall grows outward in an attempt to maintain a constant lumen diameter, while negative remodeling is defined as a local shrinkage of vessel...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.02.012
更新日期:2013-04-26 00:00:00
abstract::When recovering balance from a lateral perturbation, younger adults tend to stabilize balance with a single lateral sidestep while older adults often take multistep responses. Using multiple steps to recover balance is consistently associated with increased fall risk, altered body center of mass (CoM) control and inst...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110161
更新日期:2021-01-04 00:00:00
abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.015
更新日期:2011-09-23 00:00:00
abstract::The aim of this study was to analyze changes in gait variability and symmetry in distance runners. Fourteen competitive athletes ran on an instrumented treadmill for 10,000 m at speeds equivalent to 103% of their season's best time. Spatiotemporal and ground reaction force data were recorded at 1500, 3000, 5000, 7500 ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.08.008
更新日期:2018-10-05 00:00:00
abstract::Accidentology data showed that liver is often injured in car crashes; three types of injuries occur: hematoma, laceration and vessel failure. This paper focuses on surface laceration, which involves liver capsule and hepatic parenchyma. Liver capsule behavior has been studied but its failure properties are still uncle...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.03.038
更新日期:2010-08-10 00:00:00
abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90360-f
更新日期:1990-01-01 00:00:00
abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.04.016
更新日期:2013-06-21 00:00:00
abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.025
更新日期:2009-11-13 00:00:00
abstract::In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00141-9
更新日期:1999-01-01 00:00:00
abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.061
更新日期:2015-06-25 00:00:00
abstract::Prosthetic heart valves deployed in the left heart (aortic and mitral) are subjected to harsh hemodynamical conditions. Most of the tissue engineered heart valves have been developed for the low pressure pulmonary position because of the difficulties in fabricating a mechanically strong valve, able to withstand the sy...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.018
更新日期:2018-09-10 00:00:00
abstract::Although arterio-venous grafts (AVGs) represent the second choice as permanent vascular access for hemodialysis, this solution is still affected by a relevant failure rate due to graft thrombosis, and development of neointimal hyperplasia (IH) at the distal vein. As a key role in these processes has been attributed to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109591
更新日期:2020-02-13 00:00:00
abstract::Patterns in cell adhesion molecule expression by endothelial cells may play a role in atherogenesis. Previous studies have shown dependence of intracellular adhesion molecule-1 (ICAM-1) expression in human umbilical vein endothelial cells (HUVEC) on shear stress and have indirectly linked ICAM-1 expression to spatial ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.02.002
更新日期:2006-01-01 00:00:00
abstract::Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.011
更新日期:2011-02-03 00:00:00
abstract::Human crawling performance and technique are of broad interest to roboticists, biomechanists, and military personnel. This study explores the variables that define crawling performance in the context of an outdoor obstacle course used by military organizations worldwide to evaluate the effects of load and personal equ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.030
更新日期:2019-02-14 00:00:00