Abstract:
:Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Efficient computer models present an effective way of evaluating these characteristics. Predicted contact stress and area due to articulations at the tibio-femoral and patello-femoral interfaces indicate potential clinical performance. Previous finite element (FE) knee models have generally been used to predict contact stresses and/or areas during static or quasi-static loading conditions. Explicit dynamic FE analyses have recently been used to efficiently predict TKR kinematics and contact mechanics during dynamic loading conditions. The objective of this study was to develop and experimentally validate an explicit FE TKR model that incorporates tibio-femoral and patello-femoral articulations. For computational efficiency, we developed rigid body analyses that can reasonably reproduce the kinematics, contact pressure distribution, and contact area of a fully deformable system. Results from the deformable model showed that the patello-femoral and tibio-femoral kinematics were in good agreement with experimental knee simulator measurements. Kinematic results from the rigid body analyses were nearly identical to those from the fully deformable model, and the contact pressure and contact area correlation was acceptable given the great reduction in analysis time. Component mesh density studied had little effect on the predicted kinematics, particularly for the patellar component, and small effects on the predicted contact pressure and area. These analyses have shown that, at low computational cost, a force-control dynamic simulation of a gait cycle can yield useful and predictable results.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Halloran JP,Petrella AJ,Rullkoetter PJdoi
10.1016/j.jbiomech.2004.02.046keywords:
subject
Has Abstractpub_date
2005-02-01 00:00:00pages
323-31issue
2eissn
0021-9290issn
1873-2380pii
S0021929004000922journal_volume
38pub_type
杂志文章abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.11.030
更新日期:2014-01-22 00:00:00
abstract::Throughout life, bone is continuously turning over by the well-regulated processes of bone formation and resorption. Everyday activities damage bone, and this damage is normally repaired in a continuous remodelling process. When an imbalance in this remodelling process occurs, bones may become more susceptible to frac...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00215-3
更新日期:2001-04-01 00:00:00
abstract::Aging brings about challenges in the ability to recover balance through protective stepping, especially in the lateral direction. Previous work has suggested that lateral protective stepping during weight transfer may be affected by impaired muscle composition and performance of the hip abductors (AB) in older adults....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.10.040
更新日期:2019-01-03 00:00:00
abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90170-4
更新日期:1988-01-01 00:00:00
abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.012
更新日期:2011-02-03 00:00:00
abstract::High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.015
更新日期:2011-01-11 00:00:00
abstract::Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(96)00177-7
更新日期:1997-05-01 00:00:00
abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.06.009
更新日期:2018-08-22 00:00:00
abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.035
更新日期:2007-01-01 00:00:00
abstract::The tibia from six-week old chickens that develop idiopathic scoliosis were studied with stress relaxation experiments and torsional strength testing. Most parameters observed did not show any significant differences between tibias obtained from chickens with scoliosis and tibias from the control birds; however, the r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90046-5
更新日期:1983-01-01 00:00:00
abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.016
更新日期:2014-03-03 00:00:00
abstract::The longitudinal growth of long bones occurs in growth plates where chondrocytes synthesize cartilage that is subsequently ossified. Altered growth and subsequent deformity resulting from abnormal mechanical loading is often referred to as mechanical modulation of bone growth. This phenomenon has key implications in t...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2009.05.021
更新日期:2009-08-25 00:00:00
abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.001
更新日期:2010-03-22 00:00:00
abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.12.012
更新日期:2008-01-01 00:00:00
abstract::A challenging aspect of subject specific musculoskeletal modeling is the estimation of muscle parameters, especially optimal fiber length and tendon slack length. In this study, the method for scaling musculotendon parameters published by Winby et al. (2008), J. Biomech. 41, 1682-1688, has been reformulated, generaliz...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.11.006
更新日期:2016-01-25 00:00:00
abstract::The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the ch...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00110-x
更新日期:2000-12-01 00:00:00
abstract::Shorter generation time and the power of genetic manipulation make mice an ideal model system to study bone biology as well as bone diseases. However their small size presents a challenge to perform strength measurements, particularly of the weight-bearing cancellous bone in the murine long bones. We recently develope...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.040
更新日期:2016-05-03 00:00:00
abstract::This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00034-f
更新日期:1995-10-01 00:00:00
abstract::This paper describes a method for adjusting biomechanics platform measures of sway for loss of balance. Area and velocity measures of sway were determined in forty-seven elderly women, in double and single leg stance, first with their eyes open, then closed. Subjects were rarely able to complete 10 s trials during sin...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90025-x
更新日期:1990-01-01 00:00:00
abstract::Pedicle-screw-based motion preservation systems are often used to support a slightly degenerated disc. Such implants are intended to reduce intradiscal pressure and facet joints forces, while having a minimal effect on the motion patterns. In a probabilistic finite element study with subsequent sensitivity analysis, t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.018
更新日期:2010-11-16 00:00:00
abstract::Proper function of the female pelvic floor requires intact pelvic floor muscles (PFMs). The prevalence of pelvic floor disorders (PFDs) increases substantially with age, in part due to clinically identified deterioration of PFM function with age. However, the etiology of this decline remains largely unknown. We previo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109436
更新日期:2020-01-02 00:00:00
abstract::Individual differences in bone mass distribution at the proximal femur may be determined by daily weight-bearing physical activity (PA) since bone self-adapts according to the mechanical loads that is submitted. The aim of this study was to analyse computationally the effect of different weight-bearing PA types in the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.06.031
更新日期:2013-09-03 00:00:00
abstract::Limb salvage surgeries are performed to treat a variety of lower limb pathologies and traumatic injuries. Individuals who have undergone limb salvage surgeries may require an ankle foot orthosis (AFO) to compensate for limb impairments and restore walking ability. Understanding the effects of AFO design parameters on ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.037
更新日期:2017-08-16 00:00:00
abstract::The aim of the present study was to develop a Hill type muscle model that accounts for the effects of shortening history. For this purpose, a function was derived that relates force depression to starting length, shortening amplitude and contraction velocity. History parameters were determined from short-range isokine...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00048-7
更新日期:1998-06-01 00:00:00
abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90007-a
更新日期:1991-01-01 00:00:00
abstract::Local intracellular variations of cell mechanical properties, which are essential for vital cellular functions, have not been well characterized and are poorly understood. Here, we used results from our previous biomechanical imaging study to obtain relationships between intracellular shear modulus and prestress. We f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.08.004
更新日期:2014-09-22 00:00:00
abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.002
更新日期:2007-01-01 00:00:00
abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00196-8
更新日期:2002-02-01 00:00:00
abstract::This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimension...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00008-5
更新日期:1996-09-01 00:00:00
abstract::Aim was to develop an in vivo technique which allows determination of femoro-tibial and of femoro-patellar 3D-kinematics in TKA simultaneously. The knees of 20 healthy volunteers and of eight patients with TKA (PCR, rotating platform) were investigated. Kinematics analysis was performed in an open MR-system at differe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.03.020
更新日期:2007-01-01 00:00:00