The effect of ankle foot orthosis alignment on walking in individuals treated for traumatic lower extremity injuries.

Abstract:

:Limb salvage surgeries are performed to treat a variety of lower limb pathologies and traumatic injuries. Individuals who have undergone limb salvage surgeries may require an ankle foot orthosis (AFO) to compensate for limb impairments and restore walking ability. Understanding the effects of AFO design parameters on gait biomechanics is important to refine AFO prescription criteria. In this study sagittal plane kinematic and kinetic data, muscle activity and alignment preference were examined as individuals treated for traumatic lower extremity injuries (N=12) walked over level ground with Plantarflexed (PF), Neutral, and Dorsiflexed (DF) aligned AFOs. A PF alignment resulted in earlier center of pressure progression (p<0.007) and a resulting decrease in both internal knee extensor moment (p<0.001) and quadriceps and soleus muscle activity (p<0.014) compared to the Neutral and DF alignments without affecting the lower limb support moment. A clear alignment preference was observed, with eight participants preferring the PF over the Neutral and DF alignments. The increase in internal knee extensor moment between the PF and DF alignments in the present study is consistent with previous investigations in other patient populations, suggesting a more DF aligned AFO may affect the knee joint moment similarly across patient populations. The results of this study suggest AFO alignment is an important design parameter that affects ankle and knee joint moments and muscle activity and should be carefully considered during AFO design and clinical fitting.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Brown SE,Russell Esposito E,Wilken JM

doi

10.1016/j.jbiomech.2017.06.037

subject

Has Abstract

pub_date

2017-08-16 00:00:00

pages

51-57

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(17)30347-0

journal_volume

61

pub_type

杂志文章
  • Aerodynamic study of different cyclist positions: CFD analysis and full-scale wind-tunnel tests.

    abstract::Three different cyclist positions were evaluated with Computational Fluid Dynamics (CFD) and wind-tunnel experiments were used to provide reliable data to evaluate the accuracy of the CFD simulations. Specific features of this study are: (1) both steady Reynolds-averaged Navier-Stokes (RANS) and unsteady flow modellin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.025

    authors: Defraeye T,Blocken B,Koninckx E,Hespel P,Carmeliet J

    更新日期:2010-05-07 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • Changes in stationary upright standing and proprioceptive reflex control of foot muscles after fatiguing static foot inversion.

    abstract::We searched for the consequences of a maximal static foot inversion sustained until exhaustion on the post-exercise stationary upright standing and the proprioceptive control of the foot muscles. Twelve healthy subjects executed an unilateral maximal static foot inversion during which continuous power spectrum analyse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.005

    authors: Vie B,Gomez N,Brerro-Saby C,Weber JP,Jammes Y

    更新日期:2013-06-21 00:00:00

  • Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth's centre of resistance.

    abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.043

    authors: Schmidt F,Lapatki BG

    更新日期:2019-09-20 00:00:00

  • Adversarial autoencoder for visualization and classification of human activity: Application to a low-cost commercial force plate.

    abstract::The ability to visualize and interpret high dimensional time-series data will be critical as wearable and other sensors are adopted in rehabilitation protocols. This study proposes a latent space representation of high dimensional time-series data for data visualization. For that purpose, a deep learning model called ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109684

    authors: Hernandez V,Kulić D,Venture G

    更新日期:2020-04-16 00:00:00

  • Three-dimensional mathematical model analysis of the patellofemoral joint.

    abstract::This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90331-g

    authors: Hirokawa S

    更新日期:1991-01-01 00:00:00

  • Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study.

    abstract::Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.006

    authors: Completo A,Fonseca F,Simões JA

    更新日期:2008-01-01 00:00:00

  • Inter- and intra-rater reliability of 3D kinematics during maximum mouth opening of asymptomatic subjects.

    abstract::Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (S...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.038

    authors: Calixtre LB,Nakagawa TH,Alburquerque-Sendín F,da Silva Grüninger BL,de Sena Rosa LR,Oliveira AB

    更新日期:2017-11-07 00:00:00

  • Hamstring muscle-tendon unit lengthening and activation in instep and cut-off kicking.

    abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109482

    authors: Zhang L,Li H,Garrett WE,Liu H,Yu B

    更新日期:2020-01-23 00:00:00

  • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force.

    abstract::As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.010

    authors: Davis SP,Landis BJ,Adams ZH,Allen MG,Prausnitz MR

    更新日期:2004-08-01 00:00:00

  • Development of linear and nonlinear hand-arm vibration models using optimization and linearization techniques.

    abstract::Hand-arm vibration (HAV) models serve as an effective tool to assess the vibration characteristics of the hand-tool system and to evaluate the attenuation performance of vibration isolation mechanisms. This paper describes a methodology to identify the parameters of HAV models, whether linear or nonlinear, using mecha...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90073-n

    authors: Rakheja S,Gurram R,Gouw GJ

    更新日期:1993-10-01 00:00:00

  • Analysis of a femoral hip prosthesis designed to reduce stress shielding.

    abstract::The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the ch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00110-x

    authors: Joshi MG,Advani SG,Miller F,Santare MH

    更新日期:2000-12-01 00:00:00

  • Accuracy of a video strain measurement system.

    abstract::The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00131-x

    authors: Smutz WP,Drexler M,Berglund LJ,Growney E,An KN

    更新日期:1996-06-01 00:00:00

  • Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises.

    abstract::A subject, who had undergone surgery to replace one hip joint and the proximal half of the femur with an instrumented titanium implant, performed brief exercises whilst simultaneous measurements were made of compressive axial force in the implant using short-range wireless telemetry, ground reactions using a Kistler f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00043-7

    authors: Bassey EJ,Littlewood JJ,Taylor SJ

    更新日期:1997-03-01 00:00:00

  • A computer-controlled mechanical culture system for biological testing of articular cartilage explants.

    abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00040-7

    authors: Steinmeyer J

    更新日期:1997-08-01 00:00:00

  • Estimating the gravity induced three dimensional deformation of the breast.

    abstract::As human breast tissue is continuously deformed by gravity, it is difficult to identify the non-loaded neutral breast position from which to take measurements. To estimate the neutral nipple position, this study proposed a simple novel method to counteract the three dimensional effect of gravity on the breast using th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.012

    authors: Mills C,Sanchez A,Scurr J

    更新日期:2016-12-08 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: steady state simulations.

    abstract::This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.016

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2004-05-01 00:00:00

  • Calf muscle moment, work and efficiency in level walking; role of series elasticity.

    abstract::Moment and work of the human calf muscles in level walking were determined by means of an EMG to force processor, based on a muscle analogue (Hof and Van den Berg (1981) J. Biomechanics, 14, 747-758, 759-770, 771-785, 787-792). Nine subjects (four women, five men) walked on a level treadmill at speeds between 0.5 and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90067-2

    authors: Hof AL,Geelen BA,Van den Berg J

    更新日期:1983-01-01 00:00:00

  • Estimation of stride length in level walking using an inertial measurement unit attached to the foot: a validation of the zero velocity assumption during stance.

    abstract::In a variety of applications, inertial sensors are used to estimate spatial parameters by double integrating over time their coordinate acceleration components. In human movement applications, the drift inherent to the accelerometer signals is often reduced by exploiting the cyclical nature of gait and under the hypot...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.035

    authors: Peruzzi A,Della Croce U,Cereatti A

    更新日期:2011-07-07 00:00:00

  • Increased hip adduction during running is associated with patellofemoral pain and differs between males and females: A case-control study.

    abstract::Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.014

    authors: Neal BS,Barton CJ,Birn-Jeffery A,Morrissey D

    更新日期:2019-06-25 00:00:00

  • The effects of tensile-compressive loading mode and microarchitecture on microdamage in human vertebral cancellous bone.

    abstract::The amount of microdamage in bone tissue impairs mechanical performance and may act as a stimulus for bone remodeling. Here we determine how loading mode (tension vs. compression) and microstructure (trabecular microarchitecture, local trabecular thickness, and presence of resorption cavities) influence the number and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.011

    authors: Lambers FM,Bouman AR,Tkachenko EV,Keaveny TM,Hernandez CJ

    更新日期:2014-11-28 00:00:00

  • Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype?

    abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.011

    authors: Bonnechère B,Jansen B,Van Sint Jan S

    更新日期:2016-09-06 00:00:00

  • Geometric and kinematic modelling of a human costal slice.

    abstract::More and more powerful calculation methods are being used in the modelization of the human thorax, and considering the progress made in the domain of numerical analysis, this modelization is naturally being oriented toward the utilization of finite element methods. However, thoracic models are usually based on extreme...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90179-q

    authors: Minotti P,Lexcellent C

    更新日期:1991-01-01 00:00:00

  • Body segments decoupling in sitting: control of body posture from automatic chair adjustments.

    abstract:BACKGROUND:Individuals who cannot functionally reposition themselves adopt a passive body posture and suffer from physical discomfort in long-term sitting. To regulate body load and to prevent sitting related mobility problems, proper posture control is important. The inability to reposition underlines the importance f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.017

    authors: van Geffen P,Molier BI,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-12-05 00:00:00

  • Interlimb coordination in body-weight supported locomotion: A pilot study.

    abstract::Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.042

    authors: Seiterle S,Susko T,Artemiadis PK,Riener R,Igo Krebs H

    更新日期:2015-08-20 00:00:00

  • Runners adjust leg stiffness for their first step on a new running surface.

    abstract::Human runners adjust the stiffness of their stance leg to accommodate surface stiffness during steady state running. This adjustment allows runners to maintain similar center of mass movement (e.g., ground contact time and stride frequency) regardless of surface stiffness. When runners encounter abrupt transitions in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(99)00078-0

    authors: Ferris DP,Liang K,Farley CT

    更新日期:1999-08-01 00:00:00

  • Biofluids, cell mechanics and epigenetics: Flow-induced epigenetic mechanisms of endothelial gene expression.

    abstract::Epigenetics is the regulation of gene expression (transcription) in response to changes in the cell environment through genomic modifications that largely involve the non-coding fraction of the human genome and that cannot be attributed to modification of the primary DNA sequence. Epigenetics is dominant in establishi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.017

    authors: Davies PF,Manduchi E,Jiménez JM,Jiang YZ

    更新日期:2017-01-04 00:00:00

  • Bivariate optimization of pedalling rate and crank arm length in cycling.

    abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90016-4

    authors: Hull ML,Gonzalez H

    更新日期:1988-01-01 00:00:00

  • Measurement of whole-body vibration by double-pulsed holography.

    abstract::A technique for registering vibration and deformation patterns has been adapted for the measurement of whole-body vibration in humans. Double-exposure holographic interferometry produces three dimensional pictures of the body, allowing exact measurement of the subject's movement between the two pulses. In this study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90036-8

    authors: Wangenheim M,Holzmann P,Svensson LB

    更新日期:1984-01-01 00:00:00