Abstract:
:Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and females with and without patellofemoral pain during running. Lower limb 3D kinematics were assessed in 20 runners with patellofemoral pain (11 females, 9 males) and 20 asymptomatic runners (11 females, 9 males) during a 3 km treadmill run. Variables of interest included peak hip adduction, internal rotation and flexion angles; and peak knee flexion angle, given their previously reported association with patellofemoral pain. Age, height, mass, weekly run distance and step rate were not significantly different between groups. Mixed-sex runners with patellofemoral pain were found to run with a significantly greater peak hip adduction angle (mean difference = 4.9°, d = 0.91, 95% CI 1.4-8.2, p = 0.01) when compared to matched controls, but analyses for all other kinematic variables were non-significant. Females with patellofemoral pain ran with a significantly greater peak hip adduction angle compared to female controls (mean difference = 6.6°, p = 0.02, F = 3.41, 95% CI 0.4-12.8). Analyses for all other kinematic variables between groups (males and females with/without PFP) were non-significant. Differences in peak hip adduction between those with and without patellofemoral pain during running appear to be driven by females. This potentially highlights different kinematic treatment targets between males and females. Future research is encouraged to report lower limb kinematic variables in runners with patellofemoral pain separately for males and females.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Neal BS,Barton CJ,Birn-Jeffery A,Morrissey Ddoi
10.1016/j.jbiomech.2019.05.014subject
Has Abstractpub_date
2019-06-25 00:00:00pages
133-139eissn
0021-9290issn
1873-2380pii
S0021-9290(19)30346-Xjournal_volume
91pub_type
杂志文章abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00172-5
更新日期:2002-01-01 00:00:00
abstract::Vortex shedding at vascular anastomoses were investigated in vitro using a 20 MHz pulsed-wave Doppler velocimeter. Centreline velocity measurements were made at various axial distances in simplified polyurethane models of proximal and distal end-to-side anastomoses of angles 15, 30, 45, 60 and 80 degrees using pulsati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00056-1
更新日期:1999-07-01 00:00:00
abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.022
更新日期:2018-04-11 00:00:00
abstract::Human crawling performance and technique are of broad interest to roboticists, biomechanists, and military personnel. This study explores the variables that define crawling performance in the context of an outdoor obstacle course used by military organizations worldwide to evaluate the effects of load and personal equ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.030
更新日期:2019-02-14 00:00:00
abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.021
更新日期:2007-01-01 00:00:00
abstract::Hammocks and cradles have long been appreciated, but in a very limited way. Aside from being emotionally soothing the devices affect the skin and all deep body components. While structurally simple they are functionally quite sophisticated and could very well affect the pattern of health care across the board--acute, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(84)90089-7
更新日期:1984-01-01 00:00:00
abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/S0021-9290(03)00251-3
更新日期:2004-09-01 00:00:00
abstract::Chondrocytes in articular cartilage are regularly subjected to compression and recovery due to dynamic loading of the joint. Previous studies have investigated the elastic and viscoelastic properties of chondrocytes using micropipette aspiration techniques, but in order to calculate cell properties, these studies have...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.006
更新日期:2006-01-01 00:00:00
abstract::This study examines the age at which a femoral physeal failure ceased to occur in a mouse model of medial collateral ligament (MCL) testing. Biomechanical testing of the MCL with load to failure can result in physeal failure rather than MCL failure in skeletally immature animals. Failure mode depended significantly on...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.05.014
更新日期:2005-04-01 00:00:00
abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110122
更新日期:2020-12-02 00:00:00
abstract::The reverse shoulder prosthesis aims to restore the stability and function of pathological shoulders, but the biomechanical aspects of the geometrical changes induced by the implant are yet to be fully understood. Considering a large-scale musculoskeletal model of the upper limb, the aim of this study is to evaluate h...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.06.031
更新日期:2015-09-18 00:00:00
abstract::The tibia from six-week old chickens that develop idiopathic scoliosis were studied with stress relaxation experiments and torsional strength testing. Most parameters observed did not show any significant differences between tibias obtained from chickens with scoliosis and tibias from the control birds; however, the r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90046-5
更新日期:1983-01-01 00:00:00
abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109737
更新日期:2020-05-07 00:00:00
abstract::Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (S...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.038
更新日期:2017-11-07 00:00:00
abstract::A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00178-7
更新日期:2003-11-01 00:00:00
abstract::Stress relaxation experiments were performed on specimens from a human intervertebral disc. Specimens were made from the nucleus pulposus and from the external lamellae of the anulus fibrosus in two different orientations. Tests were run with varying moisture content so as to develop a relaxation master curve. A model...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90144-8
更新日期:1987-01-01 00:00:00
abstract::This work describes a dynamic model of the low back that incorporates extensive anatomical detail of the musculo-ligamentous-skeletal system to predict the load time histories of individual tissues. The dynamic reaction moment about L4/L5 was determined during lateral bending from a linked-segment model. This reaction...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90259-4
更新日期:1992-04-01 00:00:00
abstract::Patterns in cell adhesion molecule expression by endothelial cells may play a role in atherogenesis. Previous studies have shown dependence of intracellular adhesion molecule-1 (ICAM-1) expression in human umbilical vein endothelial cells (HUVEC) on shear stress and have indirectly linked ICAM-1 expression to spatial ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.02.002
更新日期:2006-01-01 00:00:00
abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.033
更新日期:2019-05-24 00:00:00
abstract::Multiscale models of cortical bone elasticity require a large number of parameters to describe the organization and composition of the tissue. We hypothesize that the macro-scale anisotropic elastic properties of different bones can be modeled retaining only two variable parameters, and setting the others to universal...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.03.006
更新日期:2011-05-17 00:00:00
abstract::In cementless total hip arthroplasty, osteoporosis may jeopardize the achievement of immediate stability and lead to migration of anatomically shaped femoral stems. Poor quality of proximal cancellous bone per se may also affect the rate of osseointegration. In a selected group of female total hip arthroplasty patient...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.012
更新日期:2011-01-11 00:00:00
abstract::Previous studies of compensatory stepping, in response to postural perturbation, have focussed on forward or backward stepping; however, the ability to step in other directions is of equal functional importance, since the perturbations encountered in daily life may often include a lateral component. The primary object...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00053-4
更新日期:1996-03-01 00:00:00
abstract::Radioembolization, which consist of the implantation of radioactive microspheres via intra-arterially placed microcatheter, is a safe and effective treatment for liver cancer. Nevertheless, radioembolization-related complications and side effects may arise, which are an active area of ongoing research. The catheter de...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.09.035
更新日期:2016-11-07 00:00:00
abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.045
更新日期:2012-02-02 00:00:00
abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90367-c
更新日期:1990-01-01 00:00:00
abstract::Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.036
更新日期:2014-05-07 00:00:00
abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.025
更新日期:2019-01-03 00:00:00
abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90046-6
更新日期:1985-01-01 00:00:00
abstract::Groups of rats were killed at 2, 6, 12, and 24 months of age. From dissected left and right mandibles in each rat, three pairs of transverse sections were cut at the incisal, middle, and basal regions of the incisor. One section in each pair was loaded until failure and a stress-strain curve for the periodontal ligame...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.11.013
更新日期:2004-07-01 00:00:00
abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.008
更新日期:2011-01-11 00:00:00