Ligamentous versus physeal failure in murine medial collateral ligament biomechanical testing.

Abstract:

:This study examines the age at which a femoral physeal failure ceased to occur in a mouse model of medial collateral ligament (MCL) testing. Biomechanical testing of the MCL with load to failure can result in physeal failure rather than MCL failure in skeletally immature animals. Failure mode depended significantly on age (p<0.05). Sixty percent of the knees tested at 4 months failed at the physis rather than at the ligament, whereas, only ten percent of the knees tested at 5 and 6 months failed at the physis. The mean ultimate force to failure for the specimens in which the failure occurred at the ligament was 8.1 N with a higher values for the right side versus the left (p<0.05). For the specimens in which the failure occurred at the physis, the mean ultimate force to failure was 11.2 N. We now consider that 5 month old mice are functionally skeletally mature and old enough to be tested biomechanically with few failures at the physis.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

El-Zawawy HB,Silva MJ,Sandell LJ,Wright RW

doi

10.1016/j.jbiomech.2004.05.014

keywords:

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

703-6

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021929004002520

journal_volume

38

pub_type

杂志文章
  • An activatable molecular spring reduces muscle tearing during extreme stretching.

    abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.016

    authors: Leonard TR,Joumaa V,Herzog W

    更新日期:2010-11-16 00:00:00

  • Rotational kinematics of pelvis and upper trunk at butterfly stroke: Can fins affect the dynamics of the system?

    abstract::The purpose of the present study was to investigate the rotational kinematics pattern of the upper trunk and the pelvis and the complexity-variability of their movement, during the sprint butterfly stroke between male and female swimmers with long fins (18-26 cm) and without fins. Two pairs of 3D accelerometers and gy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.004

    authors: Averianova A,Nikodelis T,Konstantakos V,Kollias I

    更新日期:2016-02-08 00:00:00

  • Comparison of tendon tensions estimated from two biomechanical models of the thumb.

    abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.052

    authors: Vigouroux L,Domalain M,Berton E

    更新日期:2009-08-07 00:00:00

  • Regional load bearing of the feline acetabulum.

    abstract:OBJECTIVE:To test if the caudal acetabulum of the cat is unloaded at mid-stance as has been asserted. MATERIALS AND METHODS:A kinematic study of five healthy cats was performed to ascertain the mid-stance angle of the hip joint, and the orientation of the pelvis and femur. Femora and pelves from 10 feline cadavers wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.035

    authors: Beck AL,Pead MJ,Draper E

    更新日期:2005-03-01 00:00:00

  • Characterisation of vortex shedding in vascular anastomosis models using pulsed Doppler ultrasound.

    abstract::Vortex shedding at vascular anastomoses were investigated in vitro using a 20 MHz pulsed-wave Doppler velocimeter. Centreline velocity measurements were made at various axial distances in simplified polyurethane models of proximal and distal end-to-side anastomoses of angles 15, 30, 45, 60 and 80 degrees using pulsati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00056-1

    authors: Gaupp S,Wang Y,How TV,Fish PJ

    更新日期:1999-07-01 00:00:00

  • Wall shear stress distribution in the human carotid siphon during pulsatile flow.

    abstract::Wall shear stress distribution in the carotid siphon, which is a multiple curved segment of the internal carotid artery, is investigated numerically under physiological flow conditions. The computer simulation of flow through the model segment is based on the time-dependent, three-dimensional Navier-Stokes equations, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90203-5

    authors: Perktold K,Florian H,Hilbert D,Peter R

    更新日期:1988-01-01 00:00:00

  • Structural and mechanical properties of the human Achilles tendon: Sex and strength effects.

    abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.009

    authors: Morrison SM,Dick TJ,Wakeling JM

    更新日期:2015-09-18 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

    abstract::Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.030

    authors: Ikeda J,Zhao C,Chen Q,Thoreson AR,An KN,Amadio PC

    更新日期:2011-06-03 00:00:00

  • Turbulence model choice for the calculation of drag forces when using the CFD method.

    abstract::The aim of this work is to specify which model of turbulence is the most adapted in order to predict the drag forces that a swimmer encounters during his movement in the fluid environment. For this, a Computational Fluid Dynamics (CFD) analysis has been undertaken with a commercial CFD code (Fluent). The problem was m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.010

    authors: Zaïdi H,Fohanno S,Taïar R,Polidori G

    更新日期:2010-02-10 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • The effects of groove height and substrate stiffness on C. elegans locomotion.

    abstract::The physical environment surrounding an animal has a significant impact on its behavior. The nematode Caenorhabditis elegans (C. elegans) has proved to be an excellent choice for understanding the adaptability of organisms crawling on soft surfaces. In this work, we investigate the modulation of C. elegans' behavioral...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.02.015

    authors: Parida L,Ghosh UU,Padmanabhan V

    更新日期:2017-04-11 00:00:00

  • Reliability of medial-longitudinal-arch measures for skin-markers based kinematic analysis.

    abstract::The medial-longitudinal arch (MLA) is perhaps the most important feature characterizing foot morphology. While current skin-markers based models of the MLA angle used in stereophotogrammetry allow to estimate foot arch shape and deformation, these do not always appear consistent with foot anatomy and with standard cli...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.017

    authors: Caravaggi P,Matias AB,Taddei UT,Ortolani M,Leardini A,Sacco ICN

    更新日期:2019-05-09 00:00:00

  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • The mechanical effects of different levels of cement penetration at the cement-bone interface.

    abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.033

    authors: Waanders D,Janssen D,Mann KA,Verdonschot N

    更新日期:2010-04-19 00:00:00

  • Straining of the intact and fractured proximal humerus under physiological-like loading.

    abstract::Surgical treatment of proximal humeral fractures remains challenging in elderly patients, primarily due to insufficient implant fixation. Both bone quality and physiological-like loading conditions are commonly overlooked during pre-clinical in vitro evaluation. However, this knowledge is necessary in order to improve...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00212-4

    authors: Maldonado ZM,Seebeck J,Heller MO,Brandt D,Hepp P,Lill H,Duda GN

    更新日期:2003-12-01 00:00:00

  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Mitogen-activated protein kinase signaling in bovine articular chondrocytes in response to fluid flow does not require calcium mobilization.

    abstract::In the present study, the role of mitogen-activated protein kinases (MAPKs) in chondrocyte mechanotransduction was investigated. We hypothesized that MAPKs participate in fluid flow-induced chondrocyte mechanotransduction. To test our hypothesis, we studied cultured chondrocytes subjected to a well-defined mechanical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00176-1

    authors: Hung CT,Henshaw DR,Wang CC,Mauck RL,Raia F,Palmer G,Chao PH,Mow VC,Ratcliffe A,Valhmu WB

    更新日期:2000-01-01 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00

  • Vertebroplasty reduces progressive ׳creep' deformity of fractured vertebrae.

    abstract::Elderly vertebrae frequently develop an "anterior wedge" deformity as a result of fracture and creep mechanisms. Injecting cement into a damaged vertebral body (vertebroplasty) is known to help restore its shape and stiffness. We now hypothesise that vertebroplasty is also effective in reducing subsequent creep deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.006

    authors: Luo J,Pollintine P,Annesley-Williams DJ,Dolan P,Adams MA

    更新日期:2016-04-11 00:00:00

  • Static optimal estimation of joint accelerations for inverse dynamics problem solution.

    abstract::In inverse dynamics computations, the accuracy of the solution strongly depends on the accuracy of the input data. In particular, estimated joint moments are highly sensitive to uncertainties in acceleration data. The aim of the present work was to improve classical inverse dynamics computations by providing an accura...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00176-8

    authors: Cahouët V,Luc M,David A

    更新日期:2002-11-01 00:00:00

  • Stepping over an obstacle increases the motions and moments of the joints of the trailing limb in young adults.

    abstract::Tripping over obstacles is the most frequently mentioned causes of falls. Thus, this study was performed to test the hypotheses that when crossing obstacles, toe-obstacle clearance and the three-dimensional motions and moments at the hip, knee, and ankle of the trailing limb (limb crossing the obstacle last) increase ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00161-3

    authors: Chou LS,Draganich LF

    更新日期:1997-04-01 00:00:00

  • Upper limb joint kinetics during manual wheelchair propulsion in patients with different levels of spinal cord injury.

    abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.021

    authors: Gil-Agudo A,Del Ama-Espinosa A,Pérez-Rizo E,Pérez-Nombela S,Pablo Rodríguez-Rodríguez L

    更新日期:2010-09-17 00:00:00

  • Determination of the Poisson's ratio of the cell: recovery properties of chondrocytes after release from complete micropipette aspiration.

    abstract::Chondrocytes in articular cartilage are regularly subjected to compression and recovery due to dynamic loading of the joint. Previous studies have investigated the elastic and viscoelastic properties of chondrocytes using micropipette aspiration techniques, but in order to calculate cell properties, these studies have...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.006

    authors: Trickey WR,Baaijens FP,Laursen TA,Alexopoulos LG,Guilak F

    更新日期:2006-01-01 00:00:00

  • Mechanical and geometrical properties of the rat semimembranosus lateralis muscle during isometric contractions.

    abstract::The orientation of the line of pull and geometrical characteristics of rat semimembranosus lateralis muscle (SM1) were measured in a plane during isometric contractions at different muscle lengths. The orientation of the line of pull was always similar in our plane of analysis. It was always aligned with the external ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90051-5

    authors: Willems ME,Huijing PA

    更新日期:1994-09-01 00:00:00

  • Design of next generation total disk replacements.

    abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.017

    authors: van den Broek PR,Huyghe JM,Wilson W,Ito K

    更新日期:2012-01-03 00:00:00

  • Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty.

    abstract::Squeaking is reported for ceramic-on-ceramic hip arthroplasty, and risk factors leading to this phenomenon have been investigated empirically in the past, this way giving hints to when this phenomenon occurs. The aim of this study is to present an experimentally validated explanation for the dynamical mechanism underl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.025

    authors: Weiss C,Hothan A,Huber G,Morlock MM,Hoffmann NP

    更新日期:2012-01-10 00:00:00

  • Force-sharing between cat soleus and gastrocnemius muscles during walking: explanations based on electrical activity, properties, and kinematics.

    abstract::Studying force sharing between synergistic muscles can be useful for understanding the functional significance of musculoskeletal redundancy and the mechanisms underlying the control of synergistic muscles. The purpose of this study was to quantify and explain force sharing between cat soleus (SO) and gastrocnemius (G...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90276-3

    authors: Prilutsky BI,Herzog W,Allinger TL

    更新日期:1994-10-01 00:00:00

  • Hydro-mechanical coupling in the periodontal ligament: a porohyperelastic finite element model.

    abstract::Harmonic tension-compression tests at 0.1, 0.5 and 1 Hz on hydrated bovine periodontal ligament (PDL) were numerically simulated. The process was modeled by finite elements (FE) within the framework of poromechanics, with the objective of isolating the contributions of the solid- and fluid phases. The solid matrix was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.019

    authors: Bergomi M,Cugnoni J,Galli M,Botsis J,Belser UC,Wiskott HW

    更新日期:2011-01-04 00:00:00