Abstract:
:Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic method; (2) the zero-point-to-zero-point double integration technique (GLP) and (3) the COP low-pass filter method (LPF). The COP and COM time series have been determined using an experimental setup with a force plate and a 3D kinematic system on six healthy young adult subjects during four different 30 s standing tasks: (a) quiet standing; (b) one leg standing; (c) voluntary oscillation about the ankles and (d) voluntary oscillation about the ankles and hips. To test the difference between the COM trajectories, the root mean square (RMS) differences between each method (three comparisons) were calculated. The RMS differences between kinematic-LPF and GLP-LPF are significantly larger than kinematic-GLP. Our results show that the GLP method is comparable to the kinematic method. Both agree with the unified theory of balance during upright stance. The GLP method is attractive in the clinical perspective because it requires only a force plate to determine the COP-COM variable, which has been demonstrated to have a high reliability.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Lafond D,Duarte M,Prince Fdoi
10.1016/S0021-9290(03)00251-3keywords:
subject
Has Abstractpub_date
2004-09-01 00:00:00pages
1421-6issue
9eissn
0021-9290issn
1873-2380pii
S0021929003002513journal_volume
37pub_type
临床试验,杂志文章abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.039
更新日期:2017-08-16 00:00:00
abstract::Nonconformity between the polyethylene liner and the metal shell may exist in modular acetabular components by design, due to manufacturing tolerances, or from locking mechanisms that attach the polyethylene liner to the metal shell. Relative motion at the liner/shell interface has been associated with backside wear, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00030-x
更新日期:1998-05-01 00:00:00
abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.049
更新日期:2015-05-01 00:00:00
abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109467
更新日期:2020-01-02 00:00:00
abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.025
更新日期:2010-08-26 00:00:00
abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.033
更新日期:2010-04-19 00:00:00
abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.06.009
更新日期:2015-09-18 00:00:00
abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.06.008
更新日期:2011-09-02 00:00:00
abstract::In this study we investigated the time course of length and velocity of muscle fascicles and tendinous tissues (TT) during isometric twitch contraction, and examined how their interaction relates to the time course of external torque and muscle fascicle force generation. From seven males, supra-maximal twitch contract...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.03.023
更新日期:2007-01-01 00:00:00
abstract::Previous studies of compensatory stepping, in response to postural perturbation, have focussed on forward or backward stepping; however, the ability to step in other directions is of equal functional importance, since the perturbations encountered in daily life may often include a lateral component. The primary object...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00053-4
更新日期:1996-03-01 00:00:00
abstract::Structural properties of articular cartilage such as proteoglycan content, collagen content and collagen alignment are known to vary over length scales as small as a few microns (Bullough and Goodfellow, 1968; Bi et al., 2006). Characterizing the resulting variation in mechanical properties is critical for understandi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.012
更新日期:2010-03-03 00:00:00
abstract::Fall prevention has an indispensable role in enhancing life expectancy and quality of life among older adults. The first step to prevent falls is to devise reliable methods to identify individuals at high fall risk. The purpose of the current study was to assess alterations in local postural muscle and central sensory...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2018.01.027
更新日期:2018-04-11 00:00:00
abstract::A dry-land rowing system was developed to provide the coach and/or athlete with quantitative information about the athlete's kinetics and kinematics while the athlete trains. This system consists of a Concept II rowing ergometer instrumented with a force transducer and potentiometer, four electrogoniometers attached t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00139-6
更新日期:2000-02-01 00:00:00
abstract::Dentin, the mineralized tissue forming the bulk of the tooth, lies between the enamel and the pulp chamber. It is a rich source of inspiration for designing novel synthetic materials due to its unique microstructure. Most of the previous studies investigating the fracture toughness of dentin have used linear-elastic f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.01.015
更新日期:2008-01-01 00:00:00
abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.016
更新日期:2019-01-23 00:00:00
abstract::Implants of microporous β-tricalcium phosphate (β-TCP) were developed for primarily stable supply of bone defects. A consistent stability over the healing period should be retained in sheep. β-TCP cylindrical shaped implants, with 7 mm diameter, 25 mm length, medium pore diameter 5 μm and 40% porosity were developed. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.040
更新日期:2015-04-13 00:00:00
abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.051
更新日期:2019-01-23 00:00:00
abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.035
更新日期:2014-09-22 00:00:00
abstract::Many research groups have studied fall impact mechanics to understand how fall severity can be reduced to prevent hip fractures. Yet, direct impact force measurements with force plates are restricted to a very limited repertoire of experimental falls. The purpose of this study was to develop a generic model for estima...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.01.033
更新日期:2017-03-21 00:00:00
abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00040-9
更新日期:2001-07-01 00:00:00
abstract::Mechanical forces play an important role in the rupture of vulnerable plaques. This process is often associated with cardiovascular syndromes, such as heart attack and stroke. In this study, magnetic resonance imaging (MRI)-based models were used to investigate the association between plaque wall stress (PWS) and coro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.11.007
更新日期:2014-01-22 00:00:00
abstract::Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been reported. This might pert...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.020
更新日期:2014-11-28 00:00:00
abstract::Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.02.010
更新日期:2013-04-26 00:00:00
abstract::In order to perform effective static stretching of the hip adductor muscles, it is necessary to clarify the position where the muscles are most stretched. However, the effective flexion angle in stretching for each adductor muscle remains unclear. The goal of this study was to investigate the effect of hip flexion ang...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109649
更新日期:2020-03-05 00:00:00
abstract::Limb salvage surgeries are performed to treat a variety of lower limb pathologies and traumatic injuries. Individuals who have undergone limb salvage surgeries may require an ankle foot orthosis (AFO) to compensate for limb impairments and restore walking ability. Understanding the effects of AFO design parameters on ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.037
更新日期:2017-08-16 00:00:00
abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109763
更新日期:2020-05-07 00:00:00
abstract::Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.013
更新日期:2016-05-03 00:00:00
abstract::Subject-specific musculoskeletal models require accurate values of muscle moment arms. The aim of this study was to compare moment arms of wrist tendons obtained from non-invasive magnetic resonance imaging (MRI) to those obtained from an in vitro experimental approach. MRI was performed on ten upper limb cadaveric sp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.024
更新日期:2018-02-08 00:00:00
abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.12.019
更新日期:2017-02-28 00:00:00
abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00057-x
更新日期:2002-07-01 00:00:00