Abstract:
:Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and in-vivo approaches. The in-vitro validation utilized cadaveric hip specimens to compare the THA motion using the DFIS technique with those measured by a radiostereometric analysis (RSA). The differences between the DFIS technique and the RSA were within 0.33±0.81 mm (mean±SD) in translation and 0.45±0.65° in rotation during dynamic motion of the hips. In the in-vivo validation, the THA kinematics of two patients during a treadmill gait was assessed for the feasibility/repeatability of the DFIS technique in measurement of THA kinematics. The poses of the THAs during the treadmill gait was measured using the DFIS technique with the maximum standard deviation of 0.35 mm in translation and of 0.55° in rotation. This study demonstrated that the DFIS technique has comparable accuracy of the RSA and is highly repeatable for measurement of dynamic THA motion, suggesting that the DFIS is a promising tool in evaluating the in-vivo THA biomechanics during functional activities.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Tsai TY,Li JS,Wang S,Lin H,Malchau H,Li G,Rubash H,Kwon YMdoi
10.1016/j.jbiomech.2013.02.010subject
Has Abstractpub_date
2013-04-26 00:00:00pages
1300-4issue
7eissn
0021-9290issn
1873-2380pii
S0021-9290(13)00090-0journal_volume
46pub_type
杂志文章abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90289-y
更新日期:1991-01-01 00:00:00
abstract::The estimation of segment inertial parameters (SIPs) is an important source of error in inverse dynamic analysis. In most individual cases SIPs are derived from extrapolation of known SIPs of a certain population through regression equations (proportional models). Another well-known method is the use of mathematical a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00086-0
更新日期:1996-05-01 00:00:00
abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.026
更新日期:2014-06-03 00:00:00
abstract::This study explored transient characteristics of body sway during single-leg quiet stance in young ballet dancers (n = 41) and young healthy adults (n = 58). We compared the groups in terms of center of pressure (CoP) parameters (CoP velocity and amplitude, averaged across the duration of the 30-s trial), and the tran...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110195
更新日期:2021-01-22 00:00:00
abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.034
更新日期:2004-06-01 00:00:00
abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.03.031
更新日期:2010-07-20 00:00:00
abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.003
更新日期:2011-04-07 00:00:00
abstract::In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in ...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2013.02.004
更新日期:2013-04-26 00:00:00
abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.03.014
更新日期:2005-01-01 00:00:00
abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.05.036
更新日期:2019-07-19 00:00:00
abstract::Human responses are critical to understanding injury biomechanics in blunt ballistic impacts, which are defined as 20-200 g projectiles impacting at 20-250 m/s. 13 human cadavers were exposed to three distinct ballistic impacts of the chest to determine force-time, deflection-time and force-deflection responses. Compa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00238-0
更新日期:2004-01-01 00:00:00
abstract::While micro-FE simulations have become a standard tool in computational biomechanics, the choice of appropriate material properties is still a relevant topic, typically involving empirical grey value-to-elastic modulus relations. We here derive the voxel-specific volume fractions of mineral, collagen, and water, from ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.06.036
更新日期:2013-10-18 00:00:00
abstract::External perturbations during pushing tasks have been suggested to be a risk factor for low-back symptoms. An experiment was designed to investigate whether self-induced and externally induced sudden stops while pushing a high inertia cart influence trunk motions, and how flexor and extensor muscles counteract these p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.08.036
更新日期:2011-01-04 00:00:00
abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.07.043
更新日期:2019-09-20 00:00:00
abstract::The progression of liver fibrosis changes the biomechanical properties of liver tissue. This study characterized and compared different liver fibrosis stages in rats in terms of viscoelasticity. Three viscoelastic models, the Voigt, Maxwell, and Zener models, were applied to experimental data from rheometer tests and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.03.013
更新日期:2016-06-14 00:00:00
abstract::The study of human locomotion and its applications are examined from a historical viewpoint. Several critical steps in the advancement of the discipline are considered in the context of addressing a particular need to answer fundamental questions regarding the process of human locomotion. In addition, changes in the m...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/s0021-9290(00)00061-0
更新日期:2000-10-01 00:00:00
abstract::It has been suspected that the mechanical environment in which a particular joint functions has an effect on the initiation or progression of degenerative joint disease. The objective of this study is to define the mechanical environment of the ankle joint, specifically, the contact areas and pressure distributions, t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90132-x
更新日期:1983-01-01 00:00:00
abstract::Side-cutting is commonly used to evaluate knee joint kinematics and kinetics in the context of anterior cruciate ligament injury risk. Many existing side-cutting studies fail to clearly define the orientation of the femoral frame and the knee axis, making comparisons between studies difficult. A femoral frame construc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.05.017
更新日期:2012-07-26 00:00:00
abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90019-5
更新日期:1989-01-01 00:00:00
abstract::The medial-longitudinal arch (MLA) is perhaps the most important feature characterizing foot morphology. While current skin-markers based models of the MLA angle used in stereophotogrammetry allow to estimate foot arch shape and deformation, these do not always appear consistent with foot anatomy and with standard cli...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.03.017
更新日期:2019-05-09 00:00:00
abstract::Micro-Finite Element (micro-FE) analysis is now widely used in biomedical research as a tool to derive bone mechanical properties as they relate to its microstructure. With the development of in vivo high-resolution peripheral quantitative CT (HR-pQCT) scanners, it can now be applied to analyze bone in-vivo in the per...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.024
更新日期:2015-03-18 00:00:00
abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.014
更新日期:2005-10-01 00:00:00
abstract::The study was designed to examine the effects of partial fatigue on specific mechanical parameters which characterise human tendons in vitro. Specimens prepared from 12 intact Extensor digitorum longus tendons of the foot were subjected to partial fatigue, equivalent to 25% of the median fatigue life, by a cyclic squa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00177-4
更新日期:2002-03-01 00:00:00
abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.026
更新日期:2010-10-19 00:00:00
abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.005
更新日期:2016-12-08 00:00:00
abstract::This study investigated the plantar pressure distribution during gait on wooden surface with different slipperiness in the presence of contaminants. Fifteen Chinese males performed 10 walking trials on a 5-m wooden walkway wearing cloth shoe in four contaminated conditions (dry, sand, water, oil). A pressure insole sy...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.11.001
更新日期:2008-01-01 00:00:00
abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.021
更新日期:2007-01-01 00:00:00
abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00065-8
更新日期:1996-04-01 00:00:00
abstract::Abdominal aortic aneurysm (AAA) is a significant health problem. Current clinical rupture-risk relies primarily on the maximum diameter of the AAA and also growth rate. However, AAAs are a patient-specific problem and recently, numerical tools have been employed to estimate rupture-potential. Alternatively, experiment...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.05.004
更新日期:2012-06-26 00:00:00
abstract::The purpose of this study was to investigate the effects of a total-contact insole with and without subthreshold mechanical random noise on the balance control in diabetic patients with mild-to-moderate peripheral neuropathy. Twenty diabetic patients with mild-to-moderate neuropathy was recruited to this study. A tota...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109656
更新日期:2020-04-16 00:00:00