The effect of walking speed on local dynamic stability is sensitive to calculation methods.

Abstract:

:Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been reported. This might pertain to methodological differences in calculating λS. Therefore, the aim was to test if different calculation methods would induce different effects of walking speed on local dynamic stability. Ten young healthy participants walked on a treadmill at five speeds (60%, 80%, 100%, 120% and 140% of preferred walking speed) for 3min each, while upper body accelerations in three directions were sampled. From these time-series, λS was calculated by three different methods using: (a) a fixed time interval and expressed as logarithmic divergence per stride-time (λS-a), (b) a fixed number of strides and expressed as logarithmic divergence per time (λS-b) and (c) a fixed number of strides and expressed as logarithmic divergence per stride-time (λS-c). Mean preferred walking speed was 1.16±0.09m/s. There was only a minor effect of walking speed on λS-a. λS-b increased with increasing walking speed indicating decreased local dynamic stability at faster walking speeds, whereas λS-c decreased with increasing walking speed indicating increased local dynamic stability at faster walking speeds. Thus, the effect of walking speed on calculated local dynamic stability was significantly different between methods used to calculate local dynamic stability. Therefore, inferences and comparisons of studies employing λS should be made with careful consideration of the calculation method.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Stenum J,Bruijn SM,Jensen BR

doi

10.1016/j.jbiomech.2014.09.020

subject

Has Abstract

pub_date

2014-11-28 00:00:00

pages

3776-9

issue

15

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00486-2

journal_volume

47

pub_type

杂志文章
  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00

  • Velocity profiles in annular perfusion chamber measured by laser-Doppler velocimetry.

    abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90081-2

    authors: Aarts PA,van Broek JA,Kuiken GD,Sixma JJ,Heethaar RM

    更新日期:1984-01-01 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • Evidence of isometric function of the flexor hallucis longus muscle in normal gait.

    abstract::Studying mechanics of the muscles spanning multiple joints provides insights into intersegmental dynamics and movement coordination. Multiarticular muscles are thought to function at "near-isometric" lengths to transfer mechanical energy between the adjacent body segments. Flexor hallucis longus (FHL) is a multiarticu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.040

    authors: Kirane YM,Michelson JD,Sharkey NA

    更新日期:2008-01-01 00:00:00

  • Effects of patella alta and patella infera on patellofemoral contact forces.

    abstract::The relationship between patella alta and patellar subluxation may, in part, reflect the relationship between the height of the patella above the tibiofemoral joint line and the patellofemoral contact force. This study reports on the direct in vitro measurement of the patellofemoral contact force, and its point of app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90222-4

    authors: Singerman R,Davy DT,Goldberg VM

    更新日期:1994-08-01 00:00:00

  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes.

    abstract::How small do pressure transducers need to be in order to faithfully measure the plantar pressure profiles (PPPs) under normal and diabetic feet? In this study, pressures were collected from five diabetic and six non-diabetic subjects using a commercial measurement system with 25 mm2 transducers. Discrete Fourier Trans...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00116-6

    authors: Davis BL,Cothren RM,Quesada P,Hanson SB,Perry JE

    更新日期:1996-07-01 00:00:00

  • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee.

    abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90378-g

    authors: Pennock GR,Clark KJ

    更新日期:1990-01-01 00:00:00

  • Development of an RSA calibration system with improved accuracy and precision.

    abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.012

    authors: Cai R,Yuan X,Rorabeck C,Bourne RB,Holdsworth DW

    更新日期:2008-01-01 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • Microdamage evaluation in human trabecular bone based on nonlinear ultrasound vibro-modulation (NUVM).

    abstract::The primary aim of this work is to investigate the potential of nonlinear ultrasound for microdamage detection in human bone. Microdamage evaluation in human bone is of great importance, because it is considered a significant parameter for characterizing fracture risk. Experiments employing nonlinear acoustic vibro-mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.12.018

    authors: Zacharias K,Balabanidou E,Hatzokos I,Rekanos IT,Trochidis A

    更新日期:2009-03-26 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials.

    abstract::Plastic deformation of sutures creates an irreversible extension during load. To test our hypothesis that such plastic deformation causes gap formation after tendon repair, we determined the plasticity of five different suture materials commonly used in tendon surgery. Prolene, Polydioxanone (PDS), Ethibond, Vicryl, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.023

    authors: Jordan MC,Boelch S,Jansen H,Meffert RH,Hoelscher-Doht S

    更新日期:2016-09-06 00:00:00

  • Ligamentous versus physeal failure in murine medial collateral ligament biomechanical testing.

    abstract::This study examines the age at which a femoral physeal failure ceased to occur in a mouse model of medial collateral ligament (MCL) testing. Biomechanical testing of the MCL with load to failure can result in physeal failure rather than MCL failure in skeletally immature animals. Failure mode depended significantly on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.014

    authors: El-Zawawy HB,Silva MJ,Sandell LJ,Wright RW

    更新日期:2005-04-01 00:00:00

  • Nuclear mechanotransduction: response of the lamina to extracellular stress with implications in aging.

    abstract::Mechnotransduction, the phenomenon by which cells respond to applied force, is necessary for normal cell processes and is implicated in the pathology of several diseases including atherosclerosis. The exact mechanisms which govern how forces can affect gene expression have not been determined, but putative direct forc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.024

    authors: Philip JT,Dahl KN

    更新日期:2008-11-14 00:00:00

  • Three-dimensional measurement of proximal radioulnar space during active forearm pronation.

    abstract::Distal biceps tendon ruptures have been reported to be associated with narrowing of the proximal radioulnar space. There have been no studies that three-dimensionally measured the distance between the bicipital tuberosity and the proximal ulna during active motion. The purpose of this study was to three-dimensionally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110120

    authors: Matsuki K,Sugaya H,Takahashi N,Tokai M,Ueda Y,Hoshika S,Hamada H,Banks SA

    更新日期:2020-12-02 00:00:00

  • Spatial distribution and remodeling of elastic modulus of bone in micro-regime as prediction of early stage osteoporosis.

    abstract::We assessed the local distribution of bone mechanical properties on a micro-nano-scale and its correlation to strain distribution. Left tibia samples were obtained from 5-month old female Sprague Dawley rats, including baseline control (n=9) and hindlimb suspended (n=9) groups. Elastic modulus was measured by nanoinde...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.052

    authors: Grover K,Lin L,Hu M,Muir J,Qin YX

    更新日期:2016-01-25 00:00:00

  • Modeling movement disorders--CRPS-related dystonia explained by abnormal proprioceptive reflexes.

    abstract::Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dyna...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.024

    authors: Mugge W,Munts AG,Schouten AC,van der Helm FC

    更新日期:2012-01-03 00:00:00

  • Evaluation of limb compartments with increased interstitial pressure. An improved noninvasive method for determining quantitative hardness.

    abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.030

    authors: Steinberg BD

    更新日期:2005-08-01 00:00:00

  • Increased hip adduction during running is associated with patellofemoral pain and differs between males and females: A case-control study.

    abstract::Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.014

    authors: Neal BS,Barton CJ,Birn-Jeffery A,Morrissey D

    更新日期:2019-06-25 00:00:00

  • Fracture-toughening mechanisms responsible for differences in work to fracture of hydrated and dehydrated dentine.

    abstract::This study investigates the nature of deformation and differences in the mechanisms of fracture and properties of dentine where there has been a loss of moisture, as may occur with removal of the pulp in the endodontic treatment of teeth. Controlled fracture toughness testing was conducted on bovine teeth to determine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00327-5

    authors: Kahler B,Swain MV,Moule A

    更新日期:2003-02-01 00:00:00

  • The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

    abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.036

    authors: Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ

    更新日期:2019-07-19 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Stiffness versus prestress relationship at subcellular length scale.

    abstract::Local intracellular variations of cell mechanical properties, which are essential for vital cellular functions, have not been well characterized and are poorly understood. Here, we used results from our previous biomechanical imaging study to obtain relationships between intracellular shear modulus and prestress. We f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.004

    authors: Canović EP,Seidl DT,Barbone PE,Smith ML,Stamenović D

    更新日期:2014-09-22 00:00:00

  • Assessment of wavelet analysis of gait in children with typical development and cerebral palsy.

    abstract::The objective of this study was to examine the use of the continuous wavelet transform (CWT) on surface electromyographic (sEMG) signals acquired from the lower extremity muscles during gait in children with typical development (TD) and cerebral palsy (CP). This was done to explore the possibility of developing a quan...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.002

    authors: Lauer RT,Stackhouse C,Shewokis PA,Smith BT,Orlin M,McCarthy JJ

    更新日期:2005-06-01 00:00:00

  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • A general approach for modelling and mathematical investigation of the human upper limb.

    abstract::This paper is an attempt to systematize and solve the problems connected with biomechanical modelling and mathematical investigation of the upper limb, when all muscles acting on the shoulder, elbow and wrist joint are included. The basic problem is the assumption of a hypothesis for the unit vectors, collinear with m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90226-q

    authors: Raikova R

    更新日期:1992-08-01 00:00:00

  • Synergistic action of static stretching and BMP-2 stimulation in the osteoblast differentiation of C2C12 myoblasts.

    abstract::Static stretching is a major type of mechanical stimuli utilized during distraction osteogenesis (DO), a general surgical method for the lengthening of bone. The molecular signals that drive the regenerative process in DO include a variety of cytokines. Among these, bone morphogenic protein (BMP, -2 and -4) has been r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.006

    authors: Kim IS,Song YM,Cho TH,Kim JY,Weber FE,Hwang SJ

    更新日期:2009-12-11 00:00:00