Modeling movement disorders--CRPS-related dystonia explained by abnormal proprioceptive reflexes.

Abstract:

:Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dynamics and neural control was developed to test hypotheses on fixed dystonia. Dystonia entails sustained muscle contractions resulting in abnormal postures. Lack of inhibition is often hypothesized to result in hyperreflexia (exaggerated reflexes), which may cause fixed dystonia. In this study the model-simulated behavior in case of several abnormal reflex settings was compared to the clinical features of dystonia: abnormal posture, sustained muscle contraction, increased stiffness, diminished voluntary control and activity-aggravation. The simulation results were rated to criteria based on characteristic features of dystonia. Three abnormal reflex scenarios were tested: (1) increased reflex sensitivity-increased sensitivity of both the agonistic and antagonistic reflex pathways; (2) imbalanced reflex offset-a static offset to the reflex pathways on the agonistic side only; and (3) imbalanced reflex sensitivity-increased sensitivity of only the agonistic reflex pathways. Increased reflex sensitivity did not fully account for the features of dystonia, despite distinct motor dysfunction, since no abnormal postures occurred. Although imbalanced reflex offset did result in an abnormal posture, it could not satisfy other criteria. Nevertheless, imbalanced reflex sensitivity with unstable force feedback in one of the antagonists closely resembled all features of dystonia. The developed neuromuscular model is an effective tool to test hypotheses on the underlying pathophysiology of movement disorders.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Mugge W,Munts AG,Schouten AC,van der Helm FC

doi

10.1016/j.jbiomech.2011.09.024

subject

Has Abstract

pub_date

2012-01-03 00:00:00

pages

90-8

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(11)00663-4

journal_volume

45

pub_type

杂志文章
  • Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

    abstract::The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00103-9

    authors: Dunning CE,Duck TR,King GJ,Johnson JA

    更新日期:2003-08-01 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • Energy-conserving impact algorithm for the heel-strike phase of gait.

    abstract::Significant ground reaction forces exceeding body weight occur during the heel-strike phase of gait. The standard methods of analytical dynamics used to solve the impact problem do not accommodate well the heel-strike collision due to the persistent contact at the front foot and presence of contact at the back foot. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00006-3

    authors: Kaplan ML,Heegaard JH

    更新日期:2000-06-01 00:00:00

  • In situ fibril stretch and sliding is location-dependent in mouse supraspinatus tendons.

    abstract::Tendons are able to transmit high loads efficiently due to their finely optimized hierarchical collagen structure. Two mechanisms by which tendons respond to load are collagen fibril sliding and deformation (stretch). Although many studies have demonstrated that regional variations in tendon structure, composition, an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.029

    authors: Connizzo BK,Sarver JJ,Han L,Soslowsky LJ

    更新日期:2014-12-18 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • Cellular force signal integration through vector logic gates.

    abstract::The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.047

    authors: Steward RL Jr,Tan C,Cheng CM,LeDuc PR

    更新日期:2015-02-26 00:00:00

  • An evaluation of anatomical and functional knee axis definition in the context of side-cutting.

    abstract::Side-cutting is commonly used to evaluate knee joint kinematics and kinetics in the context of anterior cruciate ligament injury risk. Many existing side-cutting studies fail to clearly define the orientation of the femoral frame and the knee axis, making comparisons between studies difficult. A femoral frame construc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.017

    authors: Robinson MA,Vanrenterghem J

    更新日期:2012-07-26 00:00:00

  • A passive dynamic walking robot that has a deterministic nonlinear gait.

    abstract::There is a growing body of evidence that the step-to-step variations present in human walking are related to the biomechanics of the locomotive system. However, we still have limited understanding of what biomechanical variables influence the observed nonlinear gait variations. It is necessary to develop reliable mode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.007

    authors: Kurz MJ,Judkins TN,Arellano C,Scott-Pandorf M

    更新日期:2008-01-01 00:00:00

  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • Continuum modeling of deformation and aggregation of red blood cells.

    abstract::In order to gain better understanding for rheology of an isolated red blood cell (RBC) and a group of multiple RBCs, new continuum models for describing mechanical properties of cellular structures of an RBC and inter-cellular interactions among multiple RBCs are developed. The viscous property of an RBC membrane, whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.027

    authors: Yoon D,You D

    更新日期:2016-07-26 00:00:00

  • Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA).

    abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.010

    authors: Norman TL,Shultz T,Noble G,Gruen TA,Blaha JD

    更新日期:2013-03-15 00:00:00

  • Biomechanical analyses of stair-climbing while dual-tasking.

    abstract::Stair-climbing while doing a concurrent task like talking or holding an object is a common activity of daily living which poses high risk for falls. While biomechanical analyses of overground walking during dual-tasking have been studied extensively, little is known on the biomechanics of stair-climbing while dual-tas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.024

    authors: Vallabhajosula S,Tan CW,Mukherjee M,Davidson AJ,Stergiou N

    更新日期:2015-04-13 00:00:00

  • Validity and reliability of a new in vivo ankle stiffness measurement device.

    abstract::This investigation was designed to test the validity and reliability of a new measure of inversion/eversion ankle stiffness on a unique medial/lateral swaying cradle device utilizing a test/retest with comparison to a known standard. Ankle stiffness is essential to maintaining joint stability. Most ankle injuries occu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.007

    authors: Zinder SM,Granata KP,Padua DA,Gansneder BM

    更新日期:2007-01-01 00:00:00

  • Effect of flow pulsatility on modeling the hemodynamics in the total cavopulmonary connection.

    abstract::Total cavopulmonary connection is the result of a series of palliative surgical repairs performed on patients with single ventricle heart defects. The resulting anatomy has complex and unsteady hemodynamics characterized by flow mixing and flow separation. Although varying degrees of flow pulsatility have been observe...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1016/j.jbiomech.2012.07.010

    authors: Khiabani RH,Restrepo M,Tang E,De Zélicourt D,Sotiropoulos F,Fogel M,Yoganathan AP

    更新日期:2012-09-21 00:00:00

  • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement.

    abstract::Nonconformity between the polyethylene liner and the metal shell may exist in modular acetabular components by design, due to manufacturing tolerances, or from locking mechanisms that attach the polyethylene liner to the metal shell. Relative motion at the liner/shell interface has been associated with backside wear, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00030-x

    authors: Kurtz SM,Ochoa JA,White CV,Srivastav S,Cournoyer J

    更新日期:1998-05-01 00:00:00

  • Musculoskeletal full-body models including a detailed thoracolumbar spine for children and adolescents aged 6-18 years.

    abstract::Currently available musculoskeletal inverse-dynamics thoracolumbar spine models are entirely based on data from adults and might therefore not be applicable for simulations in children and adolescents. In addition, these models lack lower extremities, which are required for comprehensive evaluations of functional acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.049

    authors: Schmid S,Burkhart KA,Allaire BT,Grindle D,Anderson DE

    更新日期:2020-03-26 00:00:00

  • Effect of foods on selected dynamic parameters of mandibular elevator muscles during symmetric incisal biting.

    abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109800

    authors: Stróżyk P,Jacek B

    更新日期:2020-06-09 00:00:00

  • Role of endplates in contributing to compression behaviors of motion segments and intervertebral discs.

    abstract::The purpose of this study was to gain an improved understanding of the mechanical behavior of the intervertebral disc in the presence and absence of the vertebral endplates. Mechanical behaviors of rat caudal motion segments, vertebrae and isolated disc explants under two different permeability conditions were investi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.013

    authors: MacLean JJ,Owen JP,Iatridis JC

    更新日期:2007-01-01 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Density and hydration of fresh and fixed human skeletal muscle.

    abstract::The maximum tetanic tension of skeletal muscle (P(0)) is often estimated based on calculation of physiological cross-sectional area (PCSA). PCSA depends on muscle volume, pennation angle, and fiber length. Studies documenting PCSA in fixed human muscles usually compute muscle volume by dividing muscle mass by density....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.10.001

    authors: Ward SR,Lieber RL

    更新日期:2005-11-01 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon.

    abstract::To test the hypothesis that stress deprivation induces over-expression of cytokines in the patellar tendon, 40 rats were divided into the following two groups. In the stress-shielded group, we slackened the patellar tendon in the right knee by drawing the patella toward the tibial tubercle with flexible wires. In the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.009

    authors: Uchida H,Tohyama H,Nagashima K,Ohba Y,Matsumoto H,Toyama Y,Yasuda K

    更新日期:2005-04-01 00:00:00

  • Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechano-sensitivity.

    abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.003

    authors: Khayyeri H,Checa S,Tägil M,Aspenberg P,Prendergast PJ

    更新日期:2011-04-07 00:00:00

  • A simulation study of vertical jumping from different starting postures.

    abstract::This paper addresses the question of whether maximal vertical jump height depends on initial jumping posture. A direct dynamics computer simulation approach was used to avoid subject preference and practice effects. The human body was modeled as four rigid segments connected by ideal hinge joints, with movement constr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00030-9

    authors: Selbie WS,Caldwell GE

    更新日期:1996-09-01 00:00:00

  • Muscle activity patterns altered during pedaling at different body orientations.

    abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00038-3

    authors: Brown DA,Kautz SA,Dairaghi CA

    更新日期:1996-10-01 00:00:00

  • Analysis of swimmers' velocity during the underwater gliding motion following grab start.

    abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.032

    authors: Elipot M,Hellard P,Taïar R,Boissière E,Rey JL,Lecat S,Houel N

    更新日期:2009-06-19 00:00:00

  • Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site.

    abstract::In the context of reconciling the mechanical properties of trabecular bone measured from in vitro mechanical testing with the true in situ behavior, recent attention has focused on the "side-artifact" which results from interruption of the trabecular network along the sides of machined specimens. The objective of this...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.008

    authors: Bevill G,Easley SK,Keaveny TM

    更新日期:2007-01-01 00:00:00