A passive dynamic walking robot that has a deterministic nonlinear gait.

Abstract:

:There is a growing body of evidence that the step-to-step variations present in human walking are related to the biomechanics of the locomotive system. However, we still have limited understanding of what biomechanical variables influence the observed nonlinear gait variations. It is necessary to develop reliable models that closely resemble the nonlinear gait dynamics in order to advance our knowledge in this scientific field. Previously, Goswami et al. [1998. A study of the passive gait of a compass-like biped robot: symmetry and chaos. International Journal of Robotic Research 17(12)] and Garcia et al. [1998. The simplest walking model: stability, complexity, and scaling. Journal of Biomechanical Engineering 120(2), 281-288] have demonstrated that passive dynamic walking computer models can exhibit a cascade of bifurcations in their gait pattern that lead to a deterministic nonlinear gait pattern. These computer models suggest that the intrinsic mechanical dynamics may be at least partially responsible for the deterministic nonlinear gait pattern; however, this has not been shown for a physical walking robot. Here we use the largest Laypunov exponent and a surrogation analysis method to confirm and extend Garcia et al.'s and Goswami et al.'s original results to a physical passive dynamic walking robot. Experimental outcomes from our walking robot further support the notion that the deterministic nonlinear step-to-step variations present in gait may be partly governed by the intrinsic mechanical dynamics of the locomotive system. Furthermore the nonlinear analysis techniques used in this investigation offer novel methods for quantifying the nature of the step-to-step variations found in human and robotic gait.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kurz MJ,Judkins TN,Arellano C,Scott-Pandorf M

doi

10.1016/j.jbiomech.2008.01.007

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

1310-6

issue

6

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(08)00009-2

journal_volume

41

pub_type

杂志文章
  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.

    abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00045-2

    authors: Hansson S

    更新日期:2000-10-01 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • A mathematical model to investigate the effects of intravenous fluid administration and fluid loss.

    abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.002

    authors: Rosalina TT,Bouwman RA,van Sambeek MRHM,van de Vosse FN,Bovendeerd PHM

    更新日期:2019-05-09 00:00:00

  • Establishing reference values for cervical spine range of motion in pre-pubescent children.

    abstract::Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.021

    authors: Lynch-Caris T,Majeske KD,Brelin-Fornari J,Nashi S

    更新日期:2008-08-28 00:00:00

  • Shear strength and toughness of trabecular bone are more sensitive to density than damage.

    abstract::Microdamage occurs in trabecular bone under normal loading, which impairs the mechanical properties. Architectural degradation associated with osteoporosis increases damage susceptibility, resulting in a cumulative negative effect on the mechanical properties. Treatments for osteoporosis could be targeted toward incre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.002

    authors: Garrison JG,Gargac JA,Niebur GL

    更新日期:2011-11-10 00:00:00

  • Compressive strain rate sensitivity of ballistic gelatin.

    abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.008

    authors: Kwon J,Subhash G

    更新日期:2010-02-10 00:00:00

  • A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator.

    abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00034-7

    authors: Bigsby RJ,Auger DD,Jin ZM,Dowson D,Hardaker CS,Fisher J

    更新日期:1998-04-01 00:00:00

  • Is a joint moment-based cost function associated with preferred cycling cadence?

    abstract::Eight experienced male cyclists (C), eight well-trained male runners (R), and eight less-trained male noncyclists (LT) were tested under multiple cadence and power output conditions to determine: (1) if the cadence at which lower extremity net joint moments are minimized (cost function cadence) was associated with pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00155-4

    authors: Marsh AP,Martin PE,Sanderson DJ

    更新日期:2000-02-01 00:00:00

  • Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

    abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.025

    authors: Zioupos P,Hansen U,Currey JD

    更新日期:2008-10-20 00:00:00

  • Muscle activities of the lower limb during level and uphill running.

    abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.028

    authors: Yokozawa T,Fujii N,Ae M

    更新日期:2007-01-01 00:00:00

  • On the importance of blood rheology for bulk flow in hemodynamic models of the carotid bifurcation.

    abstract::Here we present a study on the impact of assumptions on image-based hemodynamic simulations of healthy carotid bifurcations. In particular, we evaluate to which extent assumptions on blood rheology influence bulk flow features, driven by the fact that few studies have provided adequate insights into the influence of a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.028

    authors: Morbiducci U,Gallo D,Massai D,Ponzini R,Deriu MA,Antiga L,Redaelli A,Montevecchi FM

    更新日期:2011-09-02 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Simultaneous positive and negative external mechanical work in human walking.

    abstract::In human walking, the center of mass motion is similar to an inverted pendulum. Viewing double support as a transition from one inverted pendulum to the next, we hypothesized that the leading leg performs negative work to redirect the center of mass velocity, while simultaneously, the trailing leg performs positive wo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00169-5

    authors: Donelan JM,Kram R,Kuo AD

    更新日期:2002-01-01 00:00:00

  • Reconstruction of proximal humeral fractures without screws using a reinforced bone substitute.

    abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110138

    authors: Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra E

    更新日期:2021-01-22 00:00:00

  • Development of an RSA calibration system with improved accuracy and precision.

    abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.012

    authors: Cai R,Yuan X,Rorabeck C,Bourne RB,Holdsworth DW

    更新日期:2008-01-01 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • Electrical conductivity and ion diffusion in porcine meniscus: effects of strain, anisotropy, and tissue region.

    abstract::The purpose of the present study was to investigate the effects of mechanical strain, anisotropy, and tissue region on electrical conductivity and ion diffusivity in meniscus fibrocartilage. A one-dimensional, 4-wire conductivity experiment was employed to measure the electrical conductivity in porcine meniscus tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.011

    authors: Kleinhans KL,McMahan JB,Jackson AR

    更新日期:2016-09-06 00:00:00

  • Accuracy of a video strain measurement system.

    abstract::The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00131-x

    authors: Smutz WP,Drexler M,Berglund LJ,Growney E,An KN

    更新日期:1996-06-01 00:00:00

  • Comparative left-right mechanical testing of cancellous bone from normal femoral heads.

    abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00061-9

    authors: Banse X,Delloye C,Cornu O,Bourgois R

    更新日期:1996-10-01 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods.

    abstract::Many clinical studies suggest that local blood flow patterns are involved in the location and development of atherosclerosis. In coronary diseases, this assumption should be corroborated by quantitative information on local hemodynamic parameters such as pressure, velocity or wall shear stress. Nowadays, computational...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00179-3

    authors: Berthier B,Bouzerar R,Legallais C

    更新日期:2002-10-01 00:00:00

  • Aerodynamic study of different cyclist positions: CFD analysis and full-scale wind-tunnel tests.

    abstract::Three different cyclist positions were evaluated with Computational Fluid Dynamics (CFD) and wind-tunnel experiments were used to provide reliable data to evaluate the accuracy of the CFD simulations. Specific features of this study are: (1) both steady Reynolds-averaged Navier-Stokes (RANS) and unsteady flow modellin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.025

    authors: Defraeye T,Blocken B,Koninckx E,Hespel P,Carmeliet J

    更新日期:2010-05-07 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • A new method for the early diagnosis of brain edema/brain swelling. An experimental study in rabbits.

    abstract::The aim of the present work is to develop a non-destructive, non-invasive technique for the early diagnosis of an oncoming brain edema based on the variation of vibration characteristics of the head system (i.e. eigenfrequency spectrum and modal damping). Besides the theoretical model that supports the basic principle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.001

    authors: Kostopoulos V,Douzinas EE,Kypriades EM,Pappas YZ

    更新日期:2006-01-01 00:00:00

  • Evaluation of limb compartments with increased interstitial pressure. An improved noninvasive method for determining quantitative hardness.

    abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.030

    authors: Steinberg BD

    更新日期:2005-08-01 00:00:00

  • In-vivo 6 degrees-of-freedom kinematics of metal-on-polyethylene total hip arthroplasty during gait.

    abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.012

    authors: Tsai TY,Li JS,Wang S,Scarborough D,Kwon YM

    更新日期:2014-05-07 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00