Establishing reference values for cervical spine range of motion in pre-pubescent children.

Abstract:

:Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to no data exists for subjects under the age of 14. This study utilized the cervical range of motion device, referenced with respect to the Frankfort Plane, to measure the active cervical spine range of motion in all three cardinal planes of the human body, for 106 subjects whose ages ranged from 8 to 10 years. The active range of motion for flexion, extension, lateral extension, and rotation was calculated as 66+/-13 degrees , 85+/-14 degrees , 58+/-8 degrees , and 77+/-7 degrees , respectively, using linear statistics. The observed data significantly differed from the published American Medical Association guidelines for adults but fell within the range of the reference values for 10 year olds. Stratifying and analyzing the range of motion data with respect to gender yielded no significant effect. Appendix A analyzes the data using angular statistics, and produces virtually identical results as those from linear statistics.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lynch-Caris T,Majeske KD,Brelin-Fornari J,Nashi S

doi

10.1016/j.jbiomech.2008.06.021

subject

Has Abstract

pub_date

2008-08-28 00:00:00

pages

2714-9

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(08)00305-9

journal_volume

41

pub_type

杂志文章
  • The effect of chemically defined medium on spontaneous calcium signaling of in situ chondrocytes during long-term culture.

    abstract::Chemically defined serum-free medium has been shown to better maintain the mechanical integrity of articular cartilage explants than serum-supplemented medium during long-term in vitro culture, but little is known about its effect on cellular mechanisms. We hypothesized that the chemically defined culture medium could...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.005

    authors: Zhou Y,Park M,Cheung E,Wang L,Lu XL

    更新日期:2015-04-13 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00

  • An algorithm for determining gravity line location from posturographic recordings.

    abstract::In posturographic recordings, the center of pressure (COP) displacement does not accurately reflect migration of the gravity line (GL), the vertical line passing through the body's center of gravity, COG. Since the horizontal ground reaction force, Fx, is proportional to the horizontal acceleration of the COG its seco...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00116-4

    authors: Zatsiorsky VM,King DL

    更新日期:1998-02-01 00:00:00

  • Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.038

    authors: Bryan R,Nair PB,Taylor M

    更新日期:2009-09-18 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.010

    authors: Clément J,Raison M,Rouleau DM

    更新日期:2018-02-08 00:00:00

  • A force transducer to measure individual finger loads during activities of daily living.

    abstract::A new six-degree-of-freedom force transducer has been manufactured, with the sensitivity to measure forces in the range +/-100 N and moments of up to +/-5 Nm. The transducer incorporates two mechanical components: shear forces and bending moments are measured via a strain-gauged tubular section whilst axial forces are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00054-8

    authors: Fowler NK,Nicol AC

    更新日期:1999-07-01 00:00:00

  • Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

    abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.025

    authors: Zioupos P,Hansen U,Currey JD

    更新日期:2008-10-20 00:00:00

  • Three-dimensional measurement of proximal radioulnar space during active forearm pronation.

    abstract::Distal biceps tendon ruptures have been reported to be associated with narrowing of the proximal radioulnar space. There have been no studies that three-dimensionally measured the distance between the bicipital tuberosity and the proximal ulna during active motion. The purpose of this study was to three-dimensionally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110120

    authors: Matsuki K,Sugaya H,Takahashi N,Tokai M,Ueda Y,Hoshika S,Hamada H,Banks SA

    更新日期:2020-12-02 00:00:00

  • Gait variability magnitude but not structure is altered in essential tremor.

    abstract::Essential tremor (ET) is a common tremor disorder affecting postural/action tremor of the upper extremities and midline. Recent research revealed a cerebellar-like deficit during tandem gait in persons with ET, though spatiotemporal variability during normal gait in ET has been relatively ignored. The first purpose of...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.07.039

    authors: Roemmich RT,Zeilman PR,Vaillancourt DE,Okun MS,Hass CJ

    更新日期:2013-10-18 00:00:00

  • Photogrammetric technique applied to anthropometric study of hands.

    abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90039-x

    authors: Ghosh SK,Poirier F

    更新日期:1987-01-01 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • The influence of lower leg configurations on muscle force variability.

    abstract::The maintenance of steady contractions is required in many daily tasks. However, there is little understanding of how various lower limb configurations influence the ability to maintain force. The purpose of the current investigation was to examine the influence of joint angle on various lower-limb constant force cont...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.032

    authors: Ofori E,Shim J,Sosnoff JJ

    更新日期:2018-04-11 00:00:00

  • Mechanical properties vary for different regions of the finger extensor apparatus.

    abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.035

    authors: Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

    更新日期:2014-09-22 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

    abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.003

    authors: Han HC,Marita S,Ku DN

    更新日期:2006-01-01 00:00:00

  • Large scale simulation of red blood cell aggregation in shear flows.

    abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.010

    authors: Xu D,Kaliviotis E,Munjiza A,Avital E,Ji C,Williams J

    更新日期:2013-07-26 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00

  • Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

    abstract::This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses pa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.011

    authors: Meirson T,Orion E,Avrahami I

    更新日期:2015-07-16 00:00:00

  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Analyzing valve interstitial cell mechanics and geometry with spatial statistics.

    abstract::Understanding cell geometric and mechanical properties is crucial to understanding how cells sense and respond to their local environment. Moreover, changes to cell mechanical properties under varied micro-environmental conditions can both influence and indicate fundamental changes to cell behavior. Atomic Force Micro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.06.028

    authors: Lejeune E,Sacks MS

    更新日期:2019-08-27 00:00:00

  • The effect of isolated valgus moments on ACL strain during single-leg landing: a simulation study.

    abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.031

    authors: Shin CS,Chaudhari AM,Andriacchi TP

    更新日期:2009-02-09 00:00:00

  • On precision limits for derivatives numerically calculated from noisy data.

    abstract::This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified tha...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90082-3

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • Physical properties of cross-linked polyethylene foam (Plastazote) under clinical conditions.

    abstract::Cross-linked polyethylene foam (Plastazote) has been used in the management of painful foot disorders occurring in a number of disease processes. A series of mechanical tests have been performed under varying clinically encountered conditions to show a relationship between the deformation of the material and the load ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90101-5

    authors: Minns RJ,Craxford AD

    更新日期:1984-01-01 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Kinematic performance of a six degree-of-freedom hand model (6DHand) for use in occupational biomechanics.

    abstract::Upper extremity musculoskeletal disorders represent an important health issue across all industry sectors; as such, the need exists to develop models of the hand that provide comprehensive biomechanics during occupational tasks. Previous optical motion capture studies used a single marker on the dorsal aspect of finge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.003

    authors: Buczek FL,Sinsel EW,Gloekler DS,Wimer BM,Warren CM,Wu JZ

    更新日期:2011-06-03 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • An energy 'sources' and 'fractions' approach to the mechanical energy expenditure problem--IV. Criticism of the concept of 'energy transfers within and between links'.

    abstract::The methods of evaluation of mechanical energy economy during human movement based on the calculation of three different values of work (Wwb, Ww, Wn), corresponding to three hypothetical types of energy exchange, are subject to criticism. Only the value of work, Wwb, calculated under the assumption of energy transfers...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90006-0

    authors: Aleshinsky SY

    更新日期:1986-01-01 00:00:00