On precision limits for derivatives numerically calculated from noisy data.

Abstract:

:This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified that differentiation by Fourier series expansion gives noise exceeding the minimum value according to the error formula. (2) An index called the "Relative Noise Amplification" (RNA) is introduced. For an arbitrary differentiating filter it is defined as the noise transmission of the filter divided by the minimal noise transmission according to the above mentioned error formula. When the filter produces unbiased estimates the value of the RNA always exceeds one. The RNA can be used as a quality index for differentiating filters. The filter with the smallest value on the RNA also has the smallest amount of noise superimposed on the calculated derivatives provided the input noise is white and additive. (3) The bandwidth and the Relative Noise Amplification of differentiating filters obtained by local least squares polynomial fitting are presented. The 0th, 1st and 2nd order derivatives have been investigated for polynomials up to 8th order. These results can be used for the determination of suitable filter parameters in various applications.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lanshammar H

doi

10.1016/0021-9290(82)90082-3

subject

Has Abstract

pub_date

1982-01-01 00:00:00

pages

459-70

issue

6

eissn

0021-9290

issn

1873-2380

pii

0021-9290(82)90082-3

journal_volume

15

pub_type

杂志文章
  • Prediction of distal radius fracture in children, using a biomechanical impact model and case-control data on playground free falls.

    abstract:OBJECTIVES:To assess the ability of a biomechanical impact model to predict the likelihood of distal radius fracture in children using data gathered for a previous epidemiological case-control study of falls from playground equipment. METHODOLOGY:Factor of Risk (FR) values were generated for each of selected subjects ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.028

    authors: Davidson PL,Chalmers DJ,Stephenson SC

    更新日期:2006-01-01 00:00:00

  • In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament.

    abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109996

    authors: Connizzo BK,Naveh GRS

    更新日期:2020-10-09 00:00:00

  • A stereophotogrammetric method for determining in situ contact areas in diarthrodial joints, and a comparison with other methods.

    abstract::Determination of contact areas in diarthrodial joints is necessary for understanding the state of stress within the articular cartilage layers and the supporting bony structures. The present study describes the use of a stereophotogrammetry (SPG) system [Huiskes et al., J. Biomechanics 18, 559-570 (1985) and Ateshian ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90038-8

    authors: Ateshian GA,Kwak SD,Soslowsky LJ,Mow VC

    更新日期:1994-01-01 00:00:00

  • Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

    abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.030

    authors: Ngai V,Wimmer MA

    更新日期:2009-10-16 00:00:00

  • Human crawling performance and technique revealed by inertial measurement units.

    abstract::Human crawling performance and technique are of broad interest to roboticists, biomechanists, and military personnel. This study explores the variables that define crawling performance in the context of an outdoor obstacle course used by military organizations worldwide to evaluate the effects of load and personal equ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.030

    authors: Vitali RV,Cain SM,Davidson SP,Perkins NC

    更新日期:2019-02-14 00:00:00

  • Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison.

    abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.035

    authors: Gijsbertse K,Sprengers A,Naghibi Beidokhti H,Nillesen M,de Korte C,Verdonschot N

    更新日期:2018-05-17 00:00:00

  • Evaluation of cross-sectional geometry and mass density distributions of humans and laboratory animals using computerized tomography.

    abstract::The purpose of this study was to determine the cross-sectional geometry and mass density distribution of a young porcine subject using the X-ray computerized tomographic (CT) method and to perform a comparative study of anatomical features of this subject and a 3 yr old female child specimen. The cross-sectional CT sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90006-4

    authors: Huang HK,Suarez FR

    更新日期:1983-01-01 00:00:00

  • The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

    abstract::Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.021

    authors: Defrate LE,van der Ven A,Boyer PJ,Gill TJ,Li G

    更新日期:2006-01-01 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • Are mineralized tissues open crystal foams reinforced by crosslinked collagen? Some energy arguments.

    abstract::Which of the elementary components (hydroxyapatite (HA) crystals, collagen, non-collagenous organic matter, water) do significantly contribute to the ultrastructural elastic stiffness magnitude and anisotropy of mineralized tissues; and how, i.e. through which shapes and assemblages (which micromechanical morphology)?...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00080-5

    authors: Hellmich Ch,Ulm FJ

    更新日期:2002-09-01 00:00:00

  • Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle.

    abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.005

    authors: Chi SW,Hodgson J,Chen JS,Reggie Edgerton V,Shin DD,Roiz RA,Sinha S

    更新日期:2010-05-07 00:00:00

  • Biomechanists can revolutionize the STEM pipeline by engaging youth athletes in sports-science based STEM outreach.

    abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109511

    authors: Drazan JF

    更新日期:2020-01-23 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • β-Tricalcium phosphate for bone replacement: stability and integration in sheep.

    abstract::Implants of microporous β-tricalcium phosphate (β-TCP) were developed for primarily stable supply of bone defects. A consistent stability over the healing period should be retained in sheep. β-TCP cylindrical shaped implants, with 7 mm diameter, 25 mm length, medium pore diameter 5 μm and 40% porosity were developed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.040

    authors: Mayr HO,Suedkamp NP,Hammer T,Hein W,Hube R,Roth PV,Bernstein A

    更新日期:2015-04-13 00:00:00

  • Quantifying the history dependency of muscle recovery from a fatiguing intermittent task.

    abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.061

    authors: Rashedi E,Nussbaum MA

    更新日期:2017-01-25 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods.

    abstract::Many clinical studies suggest that local blood flow patterns are involved in the location and development of atherosclerosis. In coronary diseases, this assumption should be corroborated by quantitative information on local hemodynamic parameters such as pressure, velocity or wall shear stress. Nowadays, computational...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00179-3

    authors: Berthier B,Bouzerar R,Legallais C

    更新日期:2002-10-01 00:00:00

  • The knee joint center of rotation is predominantly on the lateral side during normal walking.

    abstract::The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees duri...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.013

    authors: Koo S,Andriacchi TP

    更新日期:2008-01-01 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA).

    abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.010

    authors: Norman TL,Shultz T,Noble G,Gruen TA,Blaha JD

    更新日期:2013-03-15 00:00:00

  • Explaining Parkinsonian postural sway variabilities using intermittent control theory.

    abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109791

    authors: Dash R,Shah VV,Palanthandalam-Madapusi HJ

    更新日期:2020-05-22 00:00:00

  • Study on modelling of PMMA bone cement polymerisation.

    abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.021

    authors: Stańczyk M

    更新日期:2005-07-01 00:00:00

  • Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

    abstract::The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.10.031

    authors: Dong RG,Dong JH,Wu JZ,Rakheja S

    更新日期:2007-01-01 00:00:00

  • An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle.

    abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.031

    authors: Chen WM,Phyau-Wui Shim V,Park SB,Lee T

    更新日期:2011-06-03 00:00:00

  • Bone strain sensation via transmembrane potential changes in surface osteoblasts: loading rate and microstructural implications.

    abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90048-j

    authors: Harrigan TP,Hamilton JJ

    更新日期:1993-02-01 00:00:00

  • Glenohumeral joint cartilage contact in the healthy adult during scapular plane elevation depression with external humeral rotation.

    abstract::The shoulder (glenohumeral) joint has the greatest range of motion of all human joints; as a result, it is particularly vulnerable to dislocation and injury. The ability to non-invasively quantify in-vivo articular cartilage contact patterns of joints has been and remains a difficult biomechanics problem. As a result,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.034

    authors: Massimini DF,Warner JJ,Li G

    更新日期:2014-09-22 00:00:00