An algorithm for determining gravity line location from posturographic recordings.

Abstract:

:In posturographic recordings, the center of pressure (COP) displacement does not accurately reflect migration of the gravity line (GL), the vertical line passing through the body's center of gravity, COG. Since the horizontal ground reaction force, Fx, is proportional to the horizontal acceleration of the COG its second integral does represent the horizontal position of the gravity line (GLP). However, the initial constants of integration, initial velocity and position, are not known. In this note, a technique for estimating these integration constants is suggested: zero-point-to-zero-point integration. This method is based on a postulation that when Fx = 0, the GLP and COP coincide. By integrating Fx from one zero point to another zero point, both the instantaneous GLP and its velocity are determined. A validation of the suggested algorithm was performed using optical methods to determine the GLP during a one legged standing tasks. Cross-correlation values of GLP determined via videography and the suggested algorithm ranged from 0.79 to 0.96. These results suggest that the zero-point-to-zero-point-integration is an acceptable technique for determining GLP from posturographic recordings.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Zatsiorsky VM,King DL

doi

10.1016/s0021-9290(97)00116-4

subject

Has Abstract

pub_date

1998-02-01 00:00:00

pages

161-4

issue

2

eissn

0021-9290

issn

1873-2380

pii

S0021929097001164

journal_volume

31

pub_type

杂志文章
  • Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

    abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.002

    authors: Miyata S,Numano T,Homma K,Tateishi T,Ushida T

    更新日期:2007-01-01 00:00:00

  • Representative 3D shape of the distal femur, modes of variation and relationship with abnormality of the trochlear region.

    abstract::The anatomy of the distal femur has a predominant influence on the mechanics of both patello- and tibio-femoral joints. Especially, the morphological degeneration of the trochlear region dramatically affects the overall knee biomechanics and, from a clinical point of view, the staging of such a degeneration is fundame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.008

    authors: Cerveri P,Belfatto A,Manzotti A

    更新日期:2019-09-20 00:00:00

  • Factors in the propagation of aortic dissections in canine thoracic aortas.

    abstract::Factors were examined which altered the propagation of aortic dissections in canine aortas. Thoracic aortas were removed from sacrificed dogs from the distal end of the arch to the diaphragm. An intimal tear was created at the proximal end of the aorta. The dissection was propagated using a pulsatile pressure system w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90268-5

    authors: van Baardwijk C,Roach MR

    更新日期:1987-01-01 00:00:00

  • Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.009

    authors: Osis ST,Hettinga BA,Leitch J,Ferber R

    更新日期:2014-08-22 00:00:00

  • Nonuniform swelling-induced residual strains in articular cartilage.

    abstract::Swelling effects in cartilage originate from an interstitial osmotic pressure generated by the presence of negatively charged proteoglycans in the tissue. This swelling pressure gives rise to a non-zero residual strain in the cartilage solid matrix in the absence of externally applied loads. Previous studies have quan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00184-5

    authors: Narmoneva DA,Wang JY,Setton LA

    更新日期:1999-04-01 00:00:00

  • Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials.

    abstract::Plastic deformation of sutures creates an irreversible extension during load. To test our hypothesis that such plastic deformation causes gap formation after tendon repair, we determined the plasticity of five different suture materials commonly used in tendon surgery. Prolene, Polydioxanone (PDS), Ethibond, Vicryl, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.023

    authors: Jordan MC,Boelch S,Jansen H,Meffert RH,Hoelscher-Doht S

    更新日期:2016-09-06 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Non-linear rotation-free shell finite-element models for aortic heart valves.

    abstract::Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.031

    authors: Gilmanov A,Stolarski H,Sotiropoulos F

    更新日期:2017-01-04 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Mechanical characterization of stomach tissue under uniaxial tensile action.

    abstract::In this article, the tensile properties of gastric wall were investigated by using biomechanical test and theoretical analysis. The samples of porcine stomach strips from smaller and greater curvature of the stomach were cut in longitudinal and circumferential direction, respectively. The loading-unloading, stress rel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.048

    authors: Jia ZG,Li W,Zhou ZR

    更新日期:2015-02-26 00:00:00

  • Body segments decoupling in sitting: control of body posture from automatic chair adjustments.

    abstract:BACKGROUND:Individuals who cannot functionally reposition themselves adopt a passive body posture and suffer from physical discomfort in long-term sitting. To regulate body load and to prevent sitting related mobility problems, proper posture control is important. The inability to reposition underlines the importance f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.017

    authors: van Geffen P,Molier BI,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-12-05 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    abstract::In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.030

    authors: Masum MA,Pickering MR,Lambert AJ,Scarvell JM,Smith PN

    更新日期:2017-09-06 00:00:00

  • An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.

    abstract::Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.009

    authors: Chardonnens J,Favre J,Aminian K

    更新日期:2012-08-31 00:00:00

  • EMG and force production of some human shoulder muscles during isometric abduction.

    abstract::Surface EMG was recorded in four subjects on three different occasions from the three parts of the deltoid, the clavicular part of the pectoralis major and from the infraspinatus muscles at different angles of abduction, in the frontal and scapular plane. The integrated EMG was related to the maximum values found for ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90037-5

    authors: Ringelberg JA

    更新日期:1985-01-01 00:00:00

  • A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear.

    abstract::Brainstem trauma occurs frequently in severe head injury, often resulting in fatal lesions due to importance of brainstem in crucial neural functions. Structurally, the brainstem is composed of bundles of axonal fibers distinctly oriented in a longitudinal direction surrounded by an extracellular matrix. We hypothesiz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00042-1

    authors: Arbogast KB,Margulies SS

    更新日期:1999-08-01 00:00:00

  • A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve.

    abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00448-7

    authors: De Hart J,Baaijens FP,Peters GW,Schreurs PJ

    更新日期:2003-05-01 00:00:00

  • Numerical errors and uncertainties in finite-element modeling of trabecular bone.

    abstract::Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00108-0

    authors: Ladd AJ,Kinney JH

    更新日期:1998-10-01 00:00:00

  • Robotic simulation of identical athletic-task kinematics on cadaveric limbs exhibits a lack of differences in knee mechanics between contralateral pairs.

    abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.019

    authors: Bates NA,McPherson AL,Nesbitt RJ,Shearn JT,Myer GD,Hewett TE

    更新日期:2017-02-28 00:00:00

  • The effect of hip flexion angle on muscle elongation of the hip adductor muscles during stretching.

    abstract::In order to perform effective static stretching of the hip adductor muscles, it is necessary to clarify the position where the muscles are most stretched. However, the effective flexion angle in stretching for each adductor muscle remains unclear. The goal of this study was to investigate the effect of hip flexion ang...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109649

    authors: Ogawa T,Saeki J,Ichihashi N

    更新日期:2020-03-05 00:00:00

  • Quantifying the history dependency of muscle recovery from a fatiguing intermittent task.

    abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.061

    authors: Rashedi E,Nussbaum MA

    更新日期:2017-01-25 00:00:00

  • Application of a mechanobiological simulation technique to stents used clinically.

    abstract::Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.014

    authors: Boyle CJ,Lennon AB,Prendergast PJ

    更新日期:2013-03-15 00:00:00

  • Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    abstract::The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine kne...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.043

    authors: Liu A,Jennings LM,Ingham E,Fisher J

    更新日期:2015-09-18 00:00:00

  • Computational and clinical investigation on the role of mechanical vibration on orthodontic tooth movement.

    abstract::The aim of this study is to investigate the biomechanics for orthodontic tooth movement (OTM) subjected to concurrent single-tooth vibration (50Hz) with conventional orthodontic force application, via a clinical study and computational simulation. Thirteen patients were recruited in the clinical study, which involved ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.012

    authors: Liao Z,Elekdag-Turk S,Turk T,Grove J,Dalci O,Chen J,Zheng K,Ali Darendeliler M,Swain M,Li Q

    更新日期:2017-07-26 00:00:00

  • Upper body accelerations during planned gait termination in young and older women.

    abstract::Transitory tasks, such as gait termination, involve interactions between neural and biomechanical factors that challenge postural stability and head stabilization patterns in older adults. The aim of the study was to compare upper body patterns of acceleration during planned gait termination at different speeds betwee...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.019

    authors: Rum L,Laudani L,Macaluso A,Vannozzi G

    更新日期:2017-12-08 00:00:00

  • Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

    abstract::The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00065-c

    authors: Cholewicki J,McGill SM,Norman RW

    更新日期:1995-03-01 00:00:00

  • Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

    abstract::The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.027

    authors: Arampatzis A,Morey-Klapsing G,Karamanidis K,DeMonte G,Stafilidis S,Brüggemann GP

    更新日期:2005-04-01 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

    abstract::Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surface...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.003

    authors: Dvinskikh NA,Blankevoort L,Foumani M,Spaan JA,Streekstra GJ

    更新日期:2010-03-22 00:00:00

  • Mechanical heterogeneities in the subendothelial matrix develop with age and decrease with exercise.

    abstract::Arterial stiffening occurs with age and is associated with lack of exercise. Notably both age and lack of exercise are major cardiovascular risk factors. While it is well established that bulk arterial stiffness increases with age, more recent data suggest that the intima, the innermost arterial layer, also stiffens d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.016

    authors: Kohn JC,Chen A,Cheng S,Kowal DR,King MR,Reinhart-King CA

    更新日期:2016-06-14 00:00:00