Non-linear rotation-free shell finite-element models for aortic heart valves.

Abstract:

:Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY) material models have been considered and compared. Uniaxial tests for those constitutive equations were performed to verify the formulation and implementation of the models. The issue of leaflets interactions during the closing of the heart valve at the end of systole is considered. The critical role of using non-linear anisotropic model for proper dynamic response of the heart valve especially during the closing phase is demonstrated quantitatively. This work contributes an efficient FE framework for simulating biological tissues and paves the way for high-fidelity flow structure interaction simulations of native and bioprosthetic aortic heart valves.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Gilmanov A,Stolarski H,Sotiropoulos F

doi

10.1016/j.jbiomech.2016.11.031

subject

Has Abstract

pub_date

2017-01-04 00:00:00

pages

56-62

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)31205-2

journal_volume

50

pub_type

杂志文章
  • In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament.

    abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109996

    authors: Connizzo BK,Naveh GRS

    更新日期:2020-10-09 00:00:00

  • Human pendulum approach to simulate and quantify locomotor impact loading.

    abstract::The understanding of impact mechanics during locomotion is important for research within the fields of injury prevention and footwear design. Instrumented missiles offer a worthy solution to the lack of control inherent in in vivo activities and to the isolated nature of tissue studies. However, missiles cannot mimic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00002-y

    authors: Lafortune MA,Lake MJ

    更新日期:1995-09-01 00:00:00

  • Are mineralized tissues open crystal foams reinforced by crosslinked collagen? Some energy arguments.

    abstract::Which of the elementary components (hydroxyapatite (HA) crystals, collagen, non-collagenous organic matter, water) do significantly contribute to the ultrastructural elastic stiffness magnitude and anisotropy of mineralized tissues; and how, i.e. through which shapes and assemblages (which micromechanical morphology)?...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00080-5

    authors: Hellmich Ch,Ulm FJ

    更新日期:2002-09-01 00:00:00

  • Stiffness versus prestress relationship at subcellular length scale.

    abstract::Local intracellular variations of cell mechanical properties, which are essential for vital cellular functions, have not been well characterized and are poorly understood. Here, we used results from our previous biomechanical imaging study to obtain relationships between intracellular shear modulus and prestress. We f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.004

    authors: Canović EP,Seidl DT,Barbone PE,Smith ML,Stamenović D

    更新日期:2014-09-22 00:00:00

  • A critical comparison of different residence time measures in aneurysms.

    abstract::Flow stagnation and residence time (RT) are important features of diseased arterial flows that influence biochemical transport processes and thrombosis. RT calculation methods are classified into Eulerian and Lagrangian approaches where several measures have been proposed to quantify RT. Each of these methods has a di...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.028

    authors: Reza MMS,Arzani A

    更新日期:2019-05-09 00:00:00

  • Microscale frictional response of bovine articular cartilage from atomic force microscopy.

    abstract::The objective of this study was to compare micro- and macroscale friction coefficients of bovine articular cartilage. Microscale measurements were performed using standard atomic force microscopy (AFM) techniques, using a 5 microm spherical probe tip. Twenty-four cylindrical osteochondral plugs were harvested in pairs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.017

    authors: Park S,Costa KD,Ateshian GA

    更新日期:2004-11-01 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • Interlimb coordination in body-weight supported locomotion: A pilot study.

    abstract::Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.042

    authors: Seiterle S,Susko T,Artemiadis PK,Riener R,Igo Krebs H

    更新日期:2015-08-20 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Application of a mechanobiological simulation technique to stents used clinically.

    abstract::Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.014

    authors: Boyle CJ,Lennon AB,Prendergast PJ

    更新日期:2013-03-15 00:00:00

  • Three-dimensional tissue deformation in subcutaneous tissues overlying bony prominences may help to explain external load transfer to the interstitium.

    abstract::Anesthetized, carefully positioned, female, weanling, white-haired pigs were used to test the hypothesis that (1) interface pressure, the pressure between the skin and an external load, can be used to predict the interstitial fluid pressure over the wings of ilia and the last dorsal spinous process and (2) three-dimen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90322-e

    authors: Dodd KT,Gross DR

    更新日期:1991-01-01 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

    abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.046

    authors: Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

    更新日期:2015-04-13 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • A new method for the early diagnosis of brain edema/brain swelling. An experimental study in rabbits.

    abstract::The aim of the present work is to develop a non-destructive, non-invasive technique for the early diagnosis of an oncoming brain edema based on the variation of vibration characteristics of the head system (i.e. eigenfrequency spectrum and modal damping). Besides the theoretical model that supports the basic principle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.001

    authors: Kostopoulos V,Douzinas EE,Kypriades EM,Pappas YZ

    更新日期:2006-01-01 00:00:00

  • A laser-aligned method for anthropometry of hands.

    abstract::We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00121-0

    authors: Highton J,Davidson P,Markham V

    更新日期:2003-09-01 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • Study of cradle and pendulum motion for applications to health care.

    abstract::Hammocks and cradles have long been appreciated, but in a very limited way. Aside from being emotionally soothing the devices affect the skin and all deep body components. While structurally simple they are functionally quite sophisticated and could very well affect the pattern of health care across the board--acute, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90089-7

    authors: Frisina W

    更新日期:1984-01-01 00:00:00

  • Model-based inverse estimation for active contraction stresses of tongue muscles using 3D surface shape in speech production.

    abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.008

    authors: Koike N,Ii S,Yoshinaga T,Nozaki K,Wada S

    更新日期:2017-11-07 00:00:00

  • Probabilistic finite element prediction of knee wear simulator mechanics.

    abstract::Computational models have recently been developed to replicate experimental conditions present in the Stanmore knee wear simulator. These finite element (FE) models, which provide a virtual platform to evaluate total knee replacement (TKR) mechanics, were validated through comparisons with experimental data for a spec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.029

    authors: Laz PJ,Pal S,Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2006-01-01 00:00:00

  • Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation.

    abstract::Accurate location of the hip joint center is essential for computation of hip kinematics and kinetics as well as for determination of the moment arms of muscles crossing the hip. The functional method of hip joint center location involves fitting a pelvis-fixed sphere to the path traced by a thigh-fixed point while a ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00052-5

    authors: Piazza SJ,Okita N,Cavanagh PR

    更新日期:2001-07-01 00:00:00

  • Mechanical properties of human atherosclerotic intima tissue.

    abstract::Progression and rupture of atherosclerotic plaques in coronary and carotid arteries are the key processes underlying myocardial infarctions and strokes. Biomechanical stress analyses to compute mechanical stresses in a plaque can potentially be used to assess plaque vulnerability. The stress analyses strongly rely on ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.01.019

    authors: Akyildiz AC,Speelman L,Gijsen FJ

    更新日期:2014-03-03 00:00:00

  • The range of axial rotation of the glenohumeral joint.

    abstract::There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.007

    authors: Southgate DF,Hill AM,Alexander S,Wallace AL,Hansen UN,Bull AM

    更新日期:2009-06-19 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing.

    abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.026

    authors: Knothe UR,Dolejs S,Matthew Miller R,Knothe Tate ML

    更新日期:2010-10-19 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • A numerical simulation of mechanical heart valve closure fluid dynamics.

    abstract::A computational fluid dynamics model for the analysis of the bileaflet mechanical heart valve closure process is presented. The objective of the study is to demonstrate the ability of the numerical model to simulate the leaflet motion during the closing phase in order to investigate the closure fluid dynamics and to e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00056-8

    authors: Lai YG,Chandran KB,Lemmon J

    更新日期:2002-07-01 00:00:00

  • Modification of spastic gait through mechanical damping.

    abstract::The effect of dissipative mechanical loads on spastic gait has been studied, to evaluate the feasibility of using mechanically damped orthoses to effect functional improvements in the gait of spastic patients. This concept is based on a hypothesis citing uninhibited, velocity-dependent stretch reflexes as a possible c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90278-7

    authors: Maki BE,Rosen MJ,Simon SR

    更新日期:1985-01-01 00:00:00

  • The effect of chemically defined medium on spontaneous calcium signaling of in situ chondrocytes during long-term culture.

    abstract::Chemically defined serum-free medium has been shown to better maintain the mechanical integrity of articular cartilage explants than serum-supplemented medium during long-term in vitro culture, but little is known about its effect on cellular mechanisms. We hypothesized that the chemically defined culture medium could...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.005

    authors: Zhou Y,Park M,Cheung E,Wang L,Lu XL

    更新日期:2015-04-13 00:00:00

  • Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

    abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109525

    authors: Nazouri M,Seifzadeh A,Masaeli E

    更新日期:2020-01-23 00:00:00