Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

Abstract:

:Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel was produced by freeze-thaw crosslinking method, and its mechanical properties such as viscoelastic and hyperplastic behavior, which cannot be obtained analytically, was investigated with a coupled finite element (FE)-optimization algorithm and stress relaxation experimental data. To obtain isotropic hyper-viscoelastic constitutive parameters of PVA scaffolds, the Mooney-Rivlin and Neo-Hooke strain energy functions, in which shear and bulk moduli varies with time, were applied. Results showed that predicted mechanical responses of scaffolds by the Mooney-Rivlin model better fitted stress-relaxation experiments than those obtained by Neo-Hooke one. Also, the properties obtained from the finite element model, such as the bulk and the shear moduli, showed that, after successful in vitro and in vivo experiments, PVA hydrogel may be introduced as a cartilage substitute for future tissue engineering therapies.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Nazouri M,Seifzadeh A,Masaeli E

doi

10.1016/j.jbiomech.2019.109525

subject

Has Abstract

pub_date

2020-01-23 00:00:00

pages

109525

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30779-1

journal_volume

99

pub_type

杂志文章
  • Regional contribution of proteoglycans to the fracture toughness of the dentin extracellular matrix.

    abstract::This study investigated the contribution of small leucine rich proteoglycans (SLRPs) to the fracture toughness of the dentin extracellular matrix (ECM) by enzymatically-assisted selective removal of glycosaminoglycan chains (GAGs) and proteoglycans (PGs) core protein. We adapted the Mode III trouser tear test to evalu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109633

    authors: Alania Y,Creighton J,Trevelin LT,Zamperini CA,Bedran-Russo AK

    更新日期:2020-03-05 00:00:00

  • The behavior of adaptive bone-remodeling simulation models.

    abstract::The process of adaptive bone remodeling can be described mathematically and simulated in a computer model, integrated with the finite element method. In the model discussed here, cortical and trabecular bone are described as continuous materials with variable density. The remodeling rule applied to simulate the remode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90056-7

    authors: Weinans H,Huiskes R,Grootenboer HJ

    更新日期:1992-12-01 00:00:00

  • Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.021

    authors: Lundberg HJ,Pedersen DR,Baer TE,Muste M,Callaghan JJ,Brown TD

    更新日期:2007-01-01 00:00:00

  • Human crawling performance and technique revealed by inertial measurement units.

    abstract::Human crawling performance and technique are of broad interest to roboticists, biomechanists, and military personnel. This study explores the variables that define crawling performance in the context of an outdoor obstacle course used by military organizations worldwide to evaluate the effects of load and personal equ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.030

    authors: Vitali RV,Cain SM,Davidson SP,Perkins NC

    更新日期:2019-02-14 00:00:00

  • Fibroblast-seeded collagen gels in response to dynamic equibiaxial mechanical stimuli: A biomechanical study.

    abstract::The remodeling of fibroblast-seeded collagen gels in response to dynamic mechanical stimuli was investigated by using a newly developed biaxial culture system capable of cyclically stretching planar soft tissues. Fibroblast-seeded collagen gels were subjected to three distinct dynamic mechanical conditions for six day...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.030

    authors: Lee PY,Liu YC,Wang MX,Hu JJ

    更新日期:2018-09-10 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique.

    abstract::The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.003

    authors: Goodship AE,Birch HL

    更新日期:2005-03-01 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • 3D kinematic and dynamic analysis of the front crawl tumble turn in elite male swimmers.

    abstract::The aim of this study was to identify kinematic and dynamic variables related to the best tumble turn times (3mRTT, the turn time from 3-m in to 3-m out, independent variable) in ten elite male swimmers using a three-dimensional (3D) underwater analysis protocol and the Lasso (least absolute shrinkage and selection op...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.043

    authors: Puel F,Morlier J,Avalos M,Mesnard M,Cid M,Hellard P

    更新日期:2012-02-02 00:00:00

  • An open source software tool to assign the material properties of bone for ABAQUS finite element simulations.

    abstract::A new software tool to assign the material properties of bone to an ABAQUS finite element mesh was created and compared with Bonemat, a similar tool originally designed to work with Ansys finite element models. Our software tool (py_bonemat_abaqus) was written in Python, which is the chosen scripting language for ABAQ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.037

    authors: Pegg EC,Gill HS

    更新日期:2016-09-06 00:00:00

  • Biaxial anisotropy of dog carotid artery: estimation of circumferential elastic modulus.

    abstract::Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90011-4

    authors: Dobrin PB

    更新日期:1986-01-01 00:00:00

  • Shank and rearfoot coordination and its variability during running in flatfoot.

    abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110119

    authors: Takabayashi T,Edama M,Inai T,Kubo M

    更新日期:2021-01-22 00:00:00

  • Assessment of wavelet analysis of gait in children with typical development and cerebral palsy.

    abstract::The objective of this study was to examine the use of the continuous wavelet transform (CWT) on surface electromyographic (sEMG) signals acquired from the lower extremity muscles during gait in children with typical development (TD) and cerebral palsy (CP). This was done to explore the possibility of developing a quan...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.002

    authors: Lauer RT,Stackhouse C,Shewokis PA,Smith BT,Orlin M,McCarthy JJ

    更新日期:2005-06-01 00:00:00

  • Measures of paraspinal muscle performance do not predict initial trunk kinematics after tripping.

    abstract::The ability to limit the trunk flexion associated with an anteriorly directed trip is a determinant of successful recovery of recovering postural stability and is subservient to rapidly detecting and correcting the imposed trunk flexion in the available time. This experiment tested the hypothesis that subjects demonst...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00142-5

    authors: Grabiner MD,Feuerbach JW,Jahnigen DW

    更新日期:1996-06-01 00:00:00

  • Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    abstract::Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utiliz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.011

    authors: Schiffman JM,Chelidze D,Adams A,Segala DB,Hasselquist L

    更新日期:2009-09-18 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload.

    abstract::Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). When COA coexists with AS, the left ventricle (LV) is facing a double hemodynamic load: a valvular load plus a vascular load. The objective of this study was to develop a lump...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.001

    authors: Keshavarz-Motamed Z,Garcia J,Pibarot P,Larose E,Kadem L

    更新日期:2011-11-10 00:00:00

  • Mechanical response of a simple finite element model of the intervertebral disc under complex loading.

    abstract::A simple axisymmetric finite element model of a human spine segment containing two adjacent vertebrae and the intervening intervertebral disc was constructed. The bodies and disc were modeled by three substructures; one to represent each of the vertebral bodies, the annulus fibrosus, and the nucleus pulposus. A semi-a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90128-3

    authors: Spilker RL,Daugirda DM,Schultz AB

    更新日期:1984-01-01 00:00:00

  • Computer simulation of blood flow in the human arm.

    abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90019-5

    authors: Balar SD,Rogge TR,Young DF

    更新日期:1989-01-01 00:00:00

  • Accuracy of an optical active-marker system to track the relative motion of rigid bodies.

    abstract::The measurement of relative motion between two moving bones is commonly accomplished for in vitro studies by attaching to each bone a series of either passive or active markers in a fixed orientation to create a rigid body (RB). This work determined the accuracy of motion between two RBs using an Optotrak optical moti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.01.017

    authors: Maletsky LP,Sun J,Morton NA

    更新日期:2007-01-01 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • Control of dynamic foot-ground interactions in male and female soccer athletes: females exhibit reduced dexterity and higher limb stiffness during landing.

    abstract::Controlling dynamic interactions between the lower limb and ground is important for skilled locomotion and may influence injury risk in athletes. It is well known that female athletes sustain anterior cruciate ligament (ACL) tears at higher rates than male athletes, and exhibit lower extremity biomechanics thought to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.038

    authors: Lyle MA,Valero-Cuevas FJ,Gregor RJ,Powers CM

    更新日期:2014-01-22 00:00:00

  • Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints.

    abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.024

    authors: Drewniak EI,Jay GD,Fleming BC,Crisco JJ

    更新日期:2009-08-25 00:00:00

  • A holistic approach to study the temporal variability in gait.

    abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.008

    authors: Federolf P,Tecante K,Nigg B

    更新日期:2012-04-30 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • The role of elastin and collagen in the softening behavior of the human thoracic aortic media.

    abstract::In a previous study we were able to accurately fit experimental data on arterial tissues at supra-physiological loads using a material model that accounts for softening/damage only in the portion of the model associated with the collagen fibers (Weisbecker et al., 2012). Naturally, this result leads to the hypothesis ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.025

    authors: Weisbecker H,Viertler C,Pierce DM,Holzapfel GA

    更新日期:2013-07-26 00:00:00

  • Similarity in the fatigue behavior of trabecular bone across site and species.

    abstract::Within the context of improving knowledge of the structure-function relations for trabecular bone for cyclic loading, we hypothesized that the S-N curve for cyclic compressive loading of trabecular bone, after accounting for differences in monotonic strength behavior, does not depend on either site or species. Thirty-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00245-8

    authors: Haddock SM,Yeh OC,Mummaneni PV,Rosenberg WS,Keaveny TM

    更新日期:2004-02-01 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

    abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.047

    authors: Janiga G,Rössl C,Skalej M,Thévenin D

    更新日期:2013-01-04 00:00:00