Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique.

Abstract:

:The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material properties of the constituent tissues it is necessary to measure cross-sectional area (CSA). Problems associated with this include damage to the structure, inaccurate values for non-uniform shapes, labour intensive techniques or requirement of expensive equipment. We describe a non-destructive technique for measurement of tendon and ligament CSA based on that of Race and Amis (J. Biomech. 29 (1996) 1207). The modified technique uses aqueous rapid curing alginate dental impression paste, digital photography and computerised image analysis. This technique is quick and simple to carry out and provides accurate values (within 0.8%) for CSA which are reproducible (coefficient of variation = 1.42%). The technique is non-destructive and can be used on specimens with an irregular shape.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Goodship AE,Birch HL

doi

10.1016/j.jbiomech.2004.05.003

keywords:

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

605-8

issue

3

eissn

0021-9290

issn

1873-2380

pii

S0021929004002222

journal_volume

38

pub_type

杂志文章
  • Mechanical and metabolic requirements for active lateral stabilization in human walking.

    abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.06.002

    authors: Donelan JM,Shipman DW,Kram R,Kuo AD

    更新日期:2004-06-01 00:00:00

  • Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison.

    abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.035

    authors: Gijsbertse K,Sprengers A,Naghibi Beidokhti H,Nillesen M,de Korte C,Verdonschot N

    更新日期:2018-05-17 00:00:00

  • Normalization of joint moments during gait: a comparison of two techniques.

    abstract::Joint moments are commonly used to characterize gait. Factors like height and weight influence these moments. This study determined which of two commonly used normalization methods, body mass or body weight times height, most reduced the effects of height and weight on peak hip, knee, and ankle external moments during...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00433-5

    authors: Moisio KC,Sumner DR,Shott S,Hurwitz DE

    更新日期:2003-04-01 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Flat medial-lateral conformity in total knee replacements does not minimize contact stresses.

    abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00172-5

    authors: Rawlinson JJ,Bartel DL

    更新日期:2002-01-01 00:00:00

  • A state-space analysis of mechanical energy generation, absorption, and transfer during pedaling.

    abstract::Seated ergometer pedaling is a motor task ideal for studying basic mechanisms of human bipedal coordination because, in contrast to standing and walking, fewer degrees of freedom are being controlled and upright balance is not a factor. As a step toward understanding how individual muscles coordinate pedaling, we inve...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00011-9

    authors: Fregly BJ,Zajac FE

    更新日期:1996-01-01 00:00:00

  • Prediction of closed-chain human arm dynamics in a crank-rotation task.

    abstract::This paper deals with the analysis of human arm movement in a crank-rotation task that is an example of environmentally constrained movements. Opening a door, rotating a steering wheel, and pushing a carriage are other typical examples of movements where the physical constraints, imposed on the hand position/orientati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.034

    authors: Davoudabadi Farahani S,Svinin M,Andersen MS,de Zee M,Rasmussen J

    更新日期:2016-09-06 00:00:00

  • Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics.

    abstract::To date, the diagnosis of whiplash injuries has been very difficult and largely based on subjective, clinical assessment. The work by Winters and Peles Multiple Muscle Systems--Biomechanics and Movement Organization. Springer, New York (1990) suggests that the use of finite helical axes (FHAs) in the neck may provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90192-9

    authors: Woltring HJ,Long K,Osterbauer PJ,Fuhr AW

    更新日期:1994-12-01 00:00:00

  • Maximum isometric arm forces in the horizontal plane.

    abstract::In this paper, we measured the maximum isometric force at the hand in eight directions in the horizontal plane and at five positions in the workplace. These endpoint forces were the result of shoulder horizontal adduction/abduction and elbow flexion/extension torques. We found that the normalized maximum forces of all...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2005.01.004

    authors: Jan Nijhof E,Gabriel DA

    更新日期:2006-01-01 00:00:00

  • Studies of human locomotion: past, present and future.

    abstract::The study of human locomotion and its applications are examined from a historical viewpoint. Several critical steps in the advancement of the discipline are considered in the context of addressing a particular need to answer fundamental questions regarding the process of human locomotion. In addition, changes in the m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(00)00061-0

    authors: Andriacchi TP,Alexander EJ

    更新日期:2000-10-01 00:00:00

  • Effects of age and sex on trunk motor control.

    abstract::The goal of the present study was to assess the effects of age and sex on trunk motor control. Fifty healthy adults (aged between 19 and 67 years, 28 males) participated in this study. Trunk motor control was assessed using force-controlled perturbations directly applied to the trunk. Admittance (inverse of lumped int...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109607

    authors: Griffioen M,van Dieën JH

    更新日期:2020-03-26 00:00:00

  • Three-dimensional mathematical model analysis of the patellofemoral joint.

    abstract::This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90331-g

    authors: Hirokawa S

    更新日期:1991-01-01 00:00:00

  • Biomechanical effect of rapid mucoperiosteal palatal tissue expansion with the use of osmotic expanders.

    abstract::The comparative study was performed to investigate the biomechanical properties (maximum tangential stiffness, maximum tangential modulus and tensile strength) of expanded mucoperiosteal palatal tissue after rapid expansion regimen correlated with histological findings. Rabbit palatal model was used to correlate the n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.012

    authors: Wysocki M,Kobus K,Szotek S,Kobielarz M,Kuropka P,Będziński R

    更新日期:2011-04-29 00:00:00

  • Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    abstract::In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.030

    authors: Masum MA,Pickering MR,Lambert AJ,Scarvell JM,Smith PN

    更新日期:2017-09-06 00:00:00

  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • Characterising skeletal muscle under large strain using eccentric and Fourier Transform-rheology.

    abstract::Characterising the passive anisotropic properties of soft tissues has been largely limited to the linear viscoelastic regime and shear loading is rarely done in the large deformation regime, despite the physiological significance of such properties. This paper demonstrates the use of eccentric rheology, which allows t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.025

    authors: Tan K,Cheng S,Jugé L,Bilston LE

    更新日期:2015-11-05 00:00:00

  • Tissue and cellular morphological changes in growth plate explants under compression.

    abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.010

    authors: Amini S,Veilleux D,Villemure I

    更新日期:2010-09-17 00:00:00

  • Similarity in the fatigue behavior of trabecular bone across site and species.

    abstract::Within the context of improving knowledge of the structure-function relations for trabecular bone for cyclic loading, we hypothesized that the S-N curve for cyclic compressive loading of trabecular bone, after accounting for differences in monotonic strength behavior, does not depend on either site or species. Thirty-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00245-8

    authors: Haddock SM,Yeh OC,Mummaneni PV,Rosenberg WS,Keaveny TM

    更新日期:2004-02-01 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00

  • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force.

    abstract::As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.010

    authors: Davis SP,Landis BJ,Adams ZH,Allen MG,Prausnitz MR

    更新日期:2004-08-01 00:00:00

  • Efficiency as a predictor of human jaw design in the sagittal plane.

    abstract::The effects of changing the direction of the bite force and of the mandibular joint reaction have been studied with a mathematical model assisted by a computer using the technique of linear programming. We conclude the following: In the sagittal plane the long axes of lower molars are each tilted in the direction that...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90246-6

    authors: Baragar FA,Osborn JW

    更新日期:1987-01-01 00:00:00

  • A comparison of methods to quantify control of the spine.

    abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109344

    authors: Bourdon E,Graham RB,van Diëen J

    更新日期:2019-11-11 00:00:00

  • A thermodynamically consistent constitutive equation for the elastic force-length relation of soft biological materials.

    abstract::Starting from the laws of thermodynamics of reversible processes, a temperature-dependent constitutive equation is derived for the elastic force-length relation of soft biological tissues. These tissues are composed of a network of fibres (mainly collagen). The equation is based on a model which uses a simplified two-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90222-4

    authors: Maes M,Vanhuyse VJ,Decraemer WF,Raman ER

    更新日期:1989-01-01 00:00:00

  • Motion of the residual femur within the socket during gait is associated with patient-reported problems in transfemoral amputees.

    abstract::The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110050

    authors: Gale T,Yang S,McGough R,Fiedler G,Anderst W

    更新日期:2020-11-09 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

    abstract::The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.10.031

    authors: Dong RG,Dong JH,Wu JZ,Rakheja S

    更新日期:2007-01-01 00:00:00

  • Collagen fibril D-period may change as a function of strain and location in ligament.

    abstract::The purpose of this study was to determine if the characteristic banding pattern (D-period) of collagen fibrils from rabbit medial collateral ligaments changes as a function of gross ligament strain and, if so, whether the changes are location dependent (insertion versus midsubstance). Femur-medial collateral ligament...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00150-0

    authors: Kukreti U,Belkoff SM

    更新日期:2000-12-01 00:00:00

  • A numerical simulation of mechanical heart valve closure fluid dynamics.

    abstract::A computational fluid dynamics model for the analysis of the bileaflet mechanical heart valve closure process is presented. The objective of the study is to demonstrate the ability of the numerical model to simulate the leaflet motion during the closing phase in order to investigate the closure fluid dynamics and to e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00056-8

    authors: Lai YG,Chandran KB,Lemmon J

    更新日期:2002-07-01 00:00:00

  • A physiological approach to the simulation of bone remodeling as a self-organizational control process.

    abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90049-3

    authors: Mullender MG,Huiskes R,Weinans H

    更新日期:1994-11-01 00:00:00

  • Mechanical heterogeneities in the subendothelial matrix develop with age and decrease with exercise.

    abstract::Arterial stiffening occurs with age and is associated with lack of exercise. Notably both age and lack of exercise are major cardiovascular risk factors. While it is well established that bulk arterial stiffness increases with age, more recent data suggest that the intima, the innermost arterial layer, also stiffens d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.016

    authors: Kohn JC,Chen A,Cheng S,Kowal DR,King MR,Reinhart-King CA

    更新日期:2016-06-14 00:00:00