A comparison of methods to quantify control of the spine.

Abstract:

:Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (SI) and local dynamic stability (LDS) are two methods of quantifying spine control. SI provides a detailed description of control but uses linearity assumptions, whereas LDS provides a "black box" non-linear assessment during dynamic movements. Therefore, the purpose of this project was to compare control outcomes of SI and LDS. 15 participants completed two tasks (SI and LDS) in a random order. For the SI task, participants were seated and ventrally perturbed at the 10th thoracic vertebrae. They were instructed to resist the perturbations (resist condition) or to relax the trunk (relax condition). Admittance was computed, and a neuromuscular control model quantified lumbar stiffness, damping and muscle spindle feedback gains. For the LDS task, participants completed three repetitive movement blocks consisting of flexion/extension, axial rotation, and complex movements. In each block, the maximum finite-time Lyapunov exponent (λmax) was estimated. A stepwise linear regression determined that λmax during the rotation task was best predicted by SI outcomes in the relax condition (adjusted R2 = 0.83). Many conditions demonstrated no relationship between λmax and SI outcomes. These findings outline the importance of a consistent framework for the assessment of spine control. This could clarify research comparisons and the understanding of the cause/effect role of LBP on spine control.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Bourdon E,Graham RB,van Diëen J

doi

10.1016/j.jbiomech.2019.109344

subject

Has Abstract

pub_date

2019-11-11 00:00:00

pages

109344

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30566-4

journal_volume

96

pub_type

杂志文章
  • Reproducibility of energy parameters in the pole vault.

    abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.027

    authors: Schade F,Arampatzis A,Brüggemann GP

    更新日期:2006-01-01 00:00:00

  • Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth's centre of resistance.

    abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.043

    authors: Schmidt F,Lapatki BG

    更新日期:2019-09-20 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • An activatable molecular spring reduces muscle tearing during extreme stretching.

    abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.016

    authors: Leonard TR,Joumaa V,Herzog W

    更新日期:2010-11-16 00:00:00

  • Influence of erythrocyte aggregation on radial migration of platelet-sized spherical particles in shear flow.

    abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.044

    authors: Guilbert C,Chayer B,Allard L,Yu FTH,Cloutier G

    更新日期:2017-08-16 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

    abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.002

    authors: Miyata S,Numano T,Homma K,Tateishi T,Ushida T

    更新日期:2007-01-01 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • Comparison of three methods to estimate the center of mass during balance assessment.

    abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/S0021-9290(03)00251-3

    authors: Lafond D,Duarte M,Prince F

    更新日期:2004-09-01 00:00:00

  • Construction of healthy arteries using computed tomography and virtual histology intravascular ultrasound.

    abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.003

    authors: Ryou HS,Kim S,Kim SW,Cho SW

    更新日期:2012-06-01 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • Three-dimensional osseo-ligamentous model of the thorax representing initiation of scoliosis by asymmetric growth.

    abstract::A biomechanical model of the human thorax was constructed to investigate how asymmetric growth of the thorax might initiate spinal lateral curvature and axial rotation as seen in scoliosis deformities. Geometric data specifying nodal points of the model were taken from stereo-radiographs of an adolescent subject. An i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90051-4

    authors: Stokes IA,Laible JP

    更新日期:1990-01-01 00:00:00

  • Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.

    abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.004

    authors: Haider IT,Speirs AD,Frei H

    更新日期:2013-09-03 00:00:00

  • Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study.

    abstract::Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.10.047

    authors: Berg P,Iosif C,Ponsonnard S,Yardin C,Janiga G,Mounayer C

    更新日期:2016-01-04 00:00:00

  • Long-term implant fixation and stress-shielding in total hip replacement.

    abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.12.021

    authors: Sumner DR

    更新日期:2015-03-18 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • Dynamic tensile properties of bovine periodontal ligament: A nonlinear viscoelastic model.

    abstract::As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.020

    authors: Oskui IZ,Hashemi A

    更新日期:2016-03-21 00:00:00

  • Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

    abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109603

    authors: Breen A,Breen A

    更新日期:2020-03-26 00:00:00

  • Towards mechanical characterization of intact endarterectomy samples of carotid arteries during inflation using Echo-CT.

    abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.016

    authors: Boekhoven RW,Rutten MC,van Sambeek MR,van de Vosse FN,Lopata RG

    更新日期:2014-03-03 00:00:00

  • Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction.

    abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.012

    authors: Tanaka E,Iwabuchi Y,Rego EB,Koolstra JH,Yamano E,Hasegawa T,Kawazoe A,Kawai N,Tanne K

    更新日期:2008-01-01 00:00:00

  • Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension.

    abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.009

    authors: Lyons M,Winter DC,Simms CK

    更新日期:2014-06-03 00:00:00

  • Velocity profiles in annular perfusion chamber measured by laser-Doppler velocimetry.

    abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90081-2

    authors: Aarts PA,van Broek JA,Kuiken GD,Sixma JJ,Heethaar RM

    更新日期:1984-01-01 00:00:00

  • Experimental determination of sarcomere force-length relationship in type-I human skeletal muscle fibers.

    abstract::The objectives of this study were to measure the active and passive force-length (F-L) relationships in type-I human single muscle fibers and to compare the results to predictions from the sliding filament model (the "standard model"). We measured isometric forces in chemically skinned fibers at different sarcomere le...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.013

    authors: Gollapudi SK,Lin DC

    更新日期:2009-09-18 00:00:00

  • Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

    abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109525

    authors: Nazouri M,Seifzadeh A,Masaeli E

    更新日期:2020-01-23 00:00:00

  • A new in vivo technique for determination of 3D kinematics and contact areas of the patello-femoral and tibio-femoral joint.

    abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.034

    authors: von Eisenhart-Rothe R,Siebert M,Bringmann C,Vogl T,Englmeier KH,Graichen H

    更新日期:2004-06-01 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • The effect of tendon viscoelastic stiffness on the dynamic performance of isometric muscle.

    abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90355-q

    authors: Baratta R,Solomonow M

    更新日期:1991-01-01 00:00:00

  • The effect of step-wise increased stretching on rat calvarial osteoblast collagen production.

    abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00237-9

    authors: Tang LL,Wang YL,Pan J,Cai SX

    更新日期:2004-01-01 00:00:00

  • Time-frequency changes in electromyographic signals after hamstring lengthening surgery in children with cerebral palsy.

    abstract::Increased knee flexion during stance is a common gait deviation in the child with cerebral palsy (CP), with distal hamstring lengthening surgeries being an accepted course of treatment. Post-operatively, improvements in gait kinematics have been reported, however little change is noted in the patterns of muscle activi...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.01.001

    authors: Lauer RT,Smith BT,Shewokis PA,McCarthy JJ,Tucker CA

    更新日期:2007-01-01 00:00:00

  • Alteration Young's moduli by protein 4.1 phosphorylation play a potential role in the deformability development of vertebrate erythrocytes.

    abstract::The mechanical properties of vertebrate erythrocytes depend on their cytoskeletal protein networks. Membrane skeleton proteins spectrin and protein 4.1 (4.1R) cross-link with actin to maintain membrane stability under mechanical stress. Phosphorylation of 4.1R alters the affinity of 4.1R for spectrin-actin binding and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.022

    authors: Tang F,Lei X,Xiong Y,Wang R,Mao J,Wang X

    更新日期:2014-10-17 00:00:00