Abstract:
:Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (SI) and local dynamic stability (LDS) are two methods of quantifying spine control. SI provides a detailed description of control but uses linearity assumptions, whereas LDS provides a "black box" non-linear assessment during dynamic movements. Therefore, the purpose of this project was to compare control outcomes of SI and LDS. 15 participants completed two tasks (SI and LDS) in a random order. For the SI task, participants were seated and ventrally perturbed at the 10th thoracic vertebrae. They were instructed to resist the perturbations (resist condition) or to relax the trunk (relax condition). Admittance was computed, and a neuromuscular control model quantified lumbar stiffness, damping and muscle spindle feedback gains. For the LDS task, participants completed three repetitive movement blocks consisting of flexion/extension, axial rotation, and complex movements. In each block, the maximum finite-time Lyapunov exponent (λmax) was estimated. A stepwise linear regression determined that λmax during the rotation task was best predicted by SI outcomes in the relax condition (adjusted R2 = 0.83). Many conditions demonstrated no relationship between λmax and SI outcomes. These findings outline the importance of a consistent framework for the assessment of spine control. This could clarify research comparisons and the understanding of the cause/effect role of LBP on spine control.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Bourdon E,Graham RB,van Diëen Jdoi
10.1016/j.jbiomech.2019.109344subject
Has Abstractpub_date
2019-11-11 00:00:00pages
109344eissn
0021-9290issn
1873-2380pii
S0021-9290(19)30566-4journal_volume
96pub_type
杂志文章abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.03.027
更新日期:2006-01-01 00:00:00
abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.07.043
更新日期:2019-09-20 00:00:00
abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.12.008
更新日期:2010-04-19 00:00:00
abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.016
更新日期:2010-11-16 00:00:00
abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.044
更新日期:2017-08-16 00:00:00
abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109939
更新日期:2020-08-26 00:00:00
abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.02.002
更新日期:2007-01-01 00:00:00
abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90220-5
更新日期:1988-01-01 00:00:00
abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/S0021-9290(03)00251-3
更新日期:2004-09-01 00:00:00
abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.003
更新日期:2012-06-01 00:00:00
abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90108-2
更新日期:1983-01-01 00:00:00
abstract::A biomechanical model of the human thorax was constructed to investigate how asymmetric growth of the thorax might initiate spinal lateral curvature and axial rotation as seen in scoliosis deformities. Geometric data specifying nodal points of the model were taken from stereo-radiographs of an adolescent subject. An i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90051-4
更新日期:1990-01-01 00:00:00
abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.07.004
更新日期:2013-09-03 00:00:00
abstract::Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.10.047
更新日期:2016-01-04 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.02.005
更新日期:2007-01-01 00:00:00
abstract::As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.020
更新日期:2016-03-21 00:00:00
abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109603
更新日期:2020-03-26 00:00:00
abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.016
更新日期:2014-03-03 00:00:00
abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.12.012
更新日期:2008-01-01 00:00:00
abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.009
更新日期:2014-06-03 00:00:00
abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(84)90081-2
更新日期:1984-01-01 00:00:00
abstract::The objectives of this study were to measure the active and passive force-length (F-L) relationships in type-I human single muscle fibers and to compare the results to predictions from the sliding filament model (the "standard model"). We measured isometric forces in chemically skinned fibers at different sarcomere le...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.013
更新日期:2009-09-18 00:00:00
abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109525
更新日期:2020-01-23 00:00:00
abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.034
更新日期:2004-06-01 00:00:00
abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.049
更新日期:2019-02-14 00:00:00
abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90355-q
更新日期:1991-01-01 00:00:00
abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00237-9
更新日期:2004-01-01 00:00:00
abstract::Increased knee flexion during stance is a common gait deviation in the child with cerebral palsy (CP), with distal hamstring lengthening surgeries being an accepted course of treatment. Post-operatively, improvements in gait kinematics have been reported, however little change is noted in the patterns of muscle activi...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2007.01.001
更新日期:2007-01-01 00:00:00
abstract::The mechanical properties of vertebrate erythrocytes depend on their cytoskeletal protein networks. Membrane skeleton proteins spectrin and protein 4.1 (4.1R) cross-link with actin to maintain membrane stability under mechanical stress. Phosphorylation of 4.1R alters the affinity of 4.1R for spectrin-actin binding and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.07.022
更新日期:2014-10-17 00:00:00