Alteration Young's moduli by protein 4.1 phosphorylation play a potential role in the deformability development of vertebrate erythrocytes.

Abstract:

:The mechanical properties of vertebrate erythrocytes depend on their cytoskeletal protein networks. Membrane skeleton proteins spectrin and protein 4.1 (4.1R) cross-link with actin to maintain membrane stability under mechanical stress. Phosphorylation of 4.1R alters the affinity of 4.1R for spectrin-actin binding and this modulates the mechanical properties of human erythrocytes. In this study, phorbol 12-myristate-13-acetate (PMA)-induced phosphorylation of 4.1R was tested, erythrocyte deformability was determined and the erythrocyte elastic modulus was detected in human, chick, frog and fish. Furthermore, amino acid sequences of the functionally important domains of 4.1R were analyzed. Results showed that PMA-induced phosphorylation of 4.1R decreased erythrocyte deformability and this property was stable after 1h. The values of Young's modulus alteration gradually decreased from human to fish (0.388 ± 0.035 kPa, 0.219 ± 0.022 kPa, 0.191 ± 0.036 kPa and 0.141 ± 0.007 kPa). Ser-312 and Ser-331 are located within the consensus sequence recognized by protein kinase C (PKC); however, Ser-331 in zebrafish was replaced by Ala-331. The sequence of the 8 aa motif from vertebrate 4.1R showed only one amino acid mutation in frog and numerous substitutions in fish. Analyses of Young's modulus suggested that the interaction between 4.1R with the spectrin-actin binding domain may have a special relationship with the development of erythrocyte deformability. In addition, amino acid mutations in 4.1R further supported this relationship. Thus, we hypothesize that alteration of membrane skeleton protein binding affinity may play a potential role in the development of erythrocyte deformability, and alteration of Young's modulus values may provide a method for determining the deformability development of vertebrate erythrocytes.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Tang F,Lei X,Xiong Y,Wang R,Mao J,Wang X

doi

10.1016/j.jbiomech.2014.07.022

subject

Has Abstract

pub_date

2014-10-17 00:00:00

pages

3400-7

issue

13

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00403-5

journal_volume

47

pub_type

杂志文章
  • In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament.

    abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109996

    authors: Connizzo BK,Naveh GRS

    更新日期:2020-10-09 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Skewness angle of interfibrillar proteoglycans increases with applied load on mitral valve chordae tendineae.

    abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.011

    authors: Liao J,Vesely I

    更新日期:2007-01-01 00:00:00

  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00

  • Theoretical study of intracellular stress fiber orientation under cyclic deformation.

    abstract::We studied stress fiber orientation under a wide range of uniaxial cyclic deformations. We devised and validated a hypothesis consisting of two parts, as follows: (1) a stress fiber aligns to avoid a mechanical stimulus in the fiber direction under cyclic deformation. This means that, among all allowable directions, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00114-7

    authors: Yamada H,Takemasa T,Yamaguchi T

    更新日期:2000-11-01 00:00:00

  • Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

    abstract::Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.033

    authors: Lerner ZF,Browning RC

    更新日期:2016-06-14 00:00:00

  • An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.

    abstract::Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.009

    authors: Chardonnens J,Favre J,Aminian K

    更新日期:2012-08-31 00:00:00

  • Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

    abstract::A truss structure was recently introduced as an interbody fusion cage. As a truss system, some of the connected elements may be in a state of compression and others in tension. This study aimed to quantify both the mean and variance of strut strains in such an implant when loaded in a simulated fusion condition with v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.051

    authors: Caffrey JP,Cory E,Wong VW,Masuda K,Chen AC,Hunt JP,Ganey TM,Sah RL

    更新日期:2016-12-08 00:00:00

  • Runners adjust leg stiffness for their first step on a new running surface.

    abstract::Human runners adjust the stiffness of their stance leg to accommodate surface stiffness during steady state running. This adjustment allows runners to maintain similar center of mass movement (e.g., ground contact time and stride frequency) regardless of surface stiffness. When runners encounter abrupt transitions in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(99)00078-0

    authors: Ferris DP,Liang K,Farley CT

    更新日期:1999-08-01 00:00:00

  • Comparison of three local frame definitions for the kinematic analysis of the fingers and the wrist.

    abstract::Because the hand is a complex poly-articular limb, numerous methods have been proposed to investigate its kinematics therefore complicating the comparison between studies and the methodological choices. With the objective of overcoming such issues, the present study compared the effect of three local frame definitions...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.025

    authors: Goislard de Monsabert B,Visser JM,Vigouroux L,Van der Helm FC,Veeger HE

    更新日期:2014-08-22 00:00:00

  • Lumbar back muscle activity of helicopter pilots and whole-body vibration.

    abstract::Several studies have attributed the prevalence of low back pain (LBP) in helicopter pilots mainly to poor posture in-flight and whole-body vibration, with the latter hypothesis particularly related to a cyclic response of the erector spine (ES) muscle to vibration. This work aims to determine if helicopter vibration a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00090-2

    authors: de Oliveira CG,Simpson DM,Nadal J

    更新日期:2001-10-01 00:00:00

  • Compact bone: numerical simulation of mechanical characteristics.

    abstract::One of the main difficulties encountered in the numerical simulation of the anisotropic elastic characteristics of compact bone is to account for the Haversian microstructure when determining the overall macroscopic behavior. Engineering analyses of such problems are usually based on 'homogenized approximations'. Comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90031-9

    authors: Crolet JM,Aoubiza B,Meunier A

    更新日期:1993-06-01 00:00:00

  • Comparison of tendon tensions estimated from two biomechanical models of the thumb.

    abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.052

    authors: Vigouroux L,Domalain M,Berton E

    更新日期:2009-08-07 00:00:00

  • Toward quantification of athetotic movements by frequency spectrum analysis.

    abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90046-6

    authors: Niku S,Henderson JM

    更新日期:1985-01-01 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Calculation of impingement-free combined cup and stem alignments based on the patient-specific pelvic tilt.

    abstract::Proper cup alignment is crucial in total hip arthroplasty for reducing impingement risks, dislocations and wear. The Lewinnek "safe zone" is often used in clinical routine. This safe zone does not consider functional aspects and dislocation can occur even when the cup is oriented within the safe zone. Functional safe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.020

    authors: Hsu J,de la Fuente M,Radermacher K

    更新日期:2019-01-03 00:00:00

  • Interaction forces and interface properties of KIF1A kinesin-alphabeta tubulin complex assessed by molecular dynamics.

    abstract::Kinesin is a microtubule-based motor protein that generates motion involved in intracellular trafficking and cell division. Even if the force-generating and enzymatic properties of kinesin were extensively studied, the molecular basis of its interaction with the microtubule is still not well understood. The aim of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.014

    authors: Aprodu I,Soncini M,Redaelli A

    更新日期:2008-11-14 00:00:00

  • Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension.

    abstract::Incisional hernia development is a significant complication after laparoscopic abdominal surgery. Intra-abdominal pressure (IAP) is known to initiate the extrusion of intestines through the abdominal wall, but there is limited data on the mechanics of IAP generation and the structural properties of rectus sheath. This...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.009

    authors: Lyons M,Winter DC,Simms CK

    更新日期:2014-06-03 00:00:00

  • Microscale frictional response of bovine articular cartilage from atomic force microscopy.

    abstract::The objective of this study was to compare micro- and macroscale friction coefficients of bovine articular cartilage. Microscale measurements were performed using standard atomic force microscopy (AFM) techniques, using a 5 microm spherical probe tip. Twenty-four cylindrical osteochondral plugs were harvested in pairs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.017

    authors: Park S,Costa KD,Ateshian GA

    更新日期:2004-11-01 00:00:00

  • Anatomic variation in the elastic inhomogeneity and anisotropy of human femoral cortical bone tissue is consistent across multiple donors.

    abstract::Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.009

    authors: Rudy DJ,Deuerling JM,Espinoza Orías AA,Roeder RK

    更新日期:2011-06-03 00:00:00

  • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee.

    abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90378-g

    authors: Pennock GR,Clark KJ

    更新日期:1990-01-01 00:00:00

  • A model-based parametric study of impact force during running.

    abstract::This paper deals with the impact force during foot-ground impact activities such as the running. A previously developed model is used for this study. The model is a lumped-parameter one consisting of four masses connected to each other via linear springs and viscous dampers. A shoe-specific nonlinear function is used ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.09.016

    authors: Zadpoor AA,Nikooyan AA,Arshi AR

    更新日期:2007-01-01 00:00:00

  • Simulation of Low Density Lipoprotein (LDL) permeation into multilayer coronary arterial wall: Interactive effects of wall shear stress and fluid-structure interaction in hypertension.

    abstract::Due to increased atherosclerosis-caused mortality, identification of its genesis and development is of great importance. Although, key factors of the origin of the disease is still unknown, it is widely believed that cholesterol particle penetration and accumulation in arterial wall is mainly responsible for further w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.029

    authors: Roustaei M,Nikmaneshi MR,Firoozabadi B

    更新日期:2018-01-23 00:00:00

  • Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.

    abstract::The hemodynamic influence of vessel shape such as bifurcation angle is not fully understood with clinical and quantitative observations being equivocal. The aim of this study is to use computational modeling to study the hemodynamic effect of shape characteristics, in particular bifurcation angle (BA), for non-stented...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.038

    authors: Beier S,Ormiston J,Webster M,Cater J,Norris S,Medrano-Gracia P,Young A,Cowan B

    更新日期:2016-06-14 00:00:00

  • An equation to calculate individual muscle contributions to joint stability.

    abstract::The purpose of the current paper was to use the energy approach to develop a simplified equation for quantifying individual muscle contributions to mechanical stability about all three axes of a particular joint. Specific examples are provided for muscles acting about the lumbar spine's L4/L5 joint. The stability equa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.004

    authors: Potvin JR,Brown SH

    更新日期:2005-05-01 00:00:00

  • Changes in segment mass and mass distribution during pregnancy.

    abstract::The purpose of the study was to evaluate the rates of change in the estimated masses and principal moments of inertia of the body segments during the second and third trimesters of pregnancy. Fifteen subjects, on average 15.1 weeks pregnant, were tested monthly until term. The body was modelled as 16 segments consisti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00042-9

    authors: Jensen RK,Doucet S,Treitz T

    更新日期:1996-02-01 00:00:00

  • Novel isodamping dynamometer accurately measures plantar flexor function.

    abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110015

    authors: Drazan JF,Hullfish TJ,Baxter JR

    更新日期:2020-10-09 00:00:00