Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

Abstract:

:Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected during treadmill walking at 1ms(-1) in 10 obese and 10 healthy-weight 8-12 year-olds. We estimated body composition, segment masses, lower-extremity alignment, and femoral neck angle via radiographic images, created personalized musculoskeletal models in OpenSim, and computed muscle forces and hip joint contact forces. Hip extension at mid-stance was 9° less, on average, in the obese children (p<0.001). Hip abduction, knee flexion, and body-weight normalized peak hip moments were similar between groups. Normalized to body-weight, peak contact forces were similar at the first peak and slightly lower at the second peak between the obese and healthy-weight participants. Total body mass explained a greater proportion of contact force variance compared to lean body mass in the compressive (r(2)=0.89) and vertical shear (perpendicular to the physis acting superior-to-inferior) (r(2)=0.84) directions; lean body mass explained a greater proportion in the posterior shear direction (r(2)=0.54). Stance-average contact forces in the compressive and vertical shear directions increased by 41N and 48N, respectively, for every kilogram of body mass. Age explained less than 27% of the hip loading variance. No effect of sex was found. The proportionality between hip loads and body-weight may be implicated in an obese child׳s increased risk of hip pain and pathology.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lerner ZF,Browning RC

doi

10.1016/j.jbiomech.2016.03.033

subject

Has Abstract

pub_date

2016-06-14 00:00:00

pages

1547-1553

issue

9

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)30354-2

journal_volume

49

pub_type

杂志文章
  • Bone strain sensation via transmembrane potential changes in surface osteoblasts: loading rate and microstructural implications.

    abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90048-j

    authors: Harrigan TP,Hamilton JJ

    更新日期:1993-02-01 00:00:00

  • Representing and identifying alternative movement techniques for goal-directed manual tasks.

    abstract::Differences in motion patterns subserving the same movement goal can be identified qualitatively. These alternatives, which may characterize 'movement techniques' (e.g., the stoop and the squat lifting technique), may be associated with significantly different biomechanical constraints and physiological responses. Des...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.014

    authors: Park W,Martin BJ,Choe S,Chaffin DB,Reed MP

    更新日期:2005-03-01 00:00:00

  • Accuracy of WAAS-enabled GPS for the determination of position and speed over ground.

    abstract::The Global Positioning System (GPS) offers many advantages over conventional methods for the determination of subject speed during biomechanical studies. Recent advances in GPS technology, in particular the implementation of the Wide-Angle Augmentation System and European Geostationary Navigation Overlay Service (WAAS...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.07.028

    authors: Witte TH,Wilson AM

    更新日期:2005-08-01 00:00:00

  • The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

    abstract::The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the seg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109886

    authors: Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

    更新日期:2020-07-17 00:00:00

  • Dominant role of interface over knee angle for cushioning impact loading and regulating initial leg stiffness.

    abstract::For in vivo impact loadings administered under controlled initial conditions, it was hypothesized that larger initial knee angles (IKA) and softer impacting interfaces would reduce impact loading and initial leg stiffness. A human pendulum was used to deliver controlled impacts to the right foot of 21 subjects for thr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Lafortune MA,Hennig EM,Lake MJ

    更新日期:1996-12-01 00:00:00

  • A two-dimensional fluid-structure interaction model of the aortic valve [correction of value].

    abstract::Failure of synthetic heart valves is usually caused by tearing and calcification of the leaflets. Leaflet fiber-reinforcement increases the durability of these valves by unloading the delicate parts of the leaflets, maintaining their physiological functioning. The interaction of the valve with the surrounding fluid is...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00068-3

    authors: De Hart J,Peters GW,Schreurs PJ,Baaijens FP

    更新日期:2000-09-01 00:00:00

  • Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.

    abstract::High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.10.002

    authors: Bourne BC,van der Meulen MC

    更新日期:2004-05-01 00:00:00

  • Prediction of closed-chain human arm dynamics in a crank-rotation task.

    abstract::This paper deals with the analysis of human arm movement in a crank-rotation task that is an example of environmentally constrained movements. Opening a door, rotating a steering wheel, and pushing a carriage are other typical examples of movements where the physical constraints, imposed on the hand position/orientati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.034

    authors: Davoudabadi Farahani S,Svinin M,Andersen MS,de Zee M,Rasmussen J

    更新日期:2016-09-06 00:00:00

  • Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    abstract::This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.020

    authors: Enders LR,Seo NJ

    更新日期:2011-05-17 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Soft tissue artifact compensation by linear 3D interpolation and approximation methods.

    abstract::Several compensation methods estimate bone pose from a cluster of skin-mounted makers, each influenced by soft tissue artifact (STA). In this study, linear 3D interpolation and approximation methods (affine mapping, Kriging and radial basis function (RBF)) and the conventional singular value decomposition (SVD) method...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.006

    authors: Dumas R,Cheze L

    更新日期:2009-09-18 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • Influence of intramuscular fiber orientation on the Achilles tendon curvature using three-dimensional finite element modeling of contracting skeletal muscle.

    abstract::Tendon curvature plays a key role in mechanical gain (amplifying the joint excursion relative to fiber length change) during joint motion, but the mechanism remains unresolved. A three-dimensional finite element (FE) model was used to investigate the influence of intramuscular fiber orientation upon the curvature patt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.014

    authors: Kinugasa R,Yamamura N,Sinha S,Takagi S

    更新日期:2016-10-03 00:00:00

  • Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

    abstract::A truss structure was recently introduced as an interbody fusion cage. As a truss system, some of the connected elements may be in a state of compression and others in tension. This study aimed to quantify both the mean and variance of strut strains in such an implant when loaded in a simulated fusion condition with v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.051

    authors: Caffrey JP,Cory E,Wong VW,Masuda K,Chen AC,Hunt JP,Ganey TM,Sah RL

    更新日期:2016-12-08 00:00:00

  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

    abstract::Improper activation of the quadriceps muscles vastus medialis (VM) and vastus lateralis (VL) has been implicated in the development of patellofemoral pain (PFP). This explanation of PFP assumes that VM and VL produce opposing mediolateral forces on the patella. Although studies have provided evidence for opposing acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.007

    authors: Sandercock TG,Wei Q,Dhaher YY,Pai DK,Tresch MC

    更新日期:2018-11-16 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Three-dimensional osseo-ligamentous model of the thorax representing initiation of scoliosis by asymmetric growth.

    abstract::A biomechanical model of the human thorax was constructed to investigate how asymmetric growth of the thorax might initiate spinal lateral curvature and axial rotation as seen in scoliosis deformities. Geometric data specifying nodal points of the model were taken from stereo-radiographs of an adolescent subject. An i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90051-4

    authors: Stokes IA,Laible JP

    更新日期:1990-01-01 00:00:00

  • Trunk stiffness and dynamics during active extension exertions.

    abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.014

    authors: Moorhouse KM,Granata KP

    更新日期:2005-10-01 00:00:00

  • An application of beam theory to determine the stress and deformation of long bones.

    abstract::We present a generalized beam theory in which deformation and load are determined simultaneously, in order to analyze statically indeterminant problems involving long bones. We regard a long bone as a beam curved in three dimensions for which the cross-sectional properties vary continuously along its length. The theor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90087-0

    authors: Salathe EP Jr,Arangio GA,Salathe EP

    更新日期:1989-01-01 00:00:00

  • Pressure distribution over the palm region during forward falls on the outstretched hands.

    abstract::Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.011

    authors: Choi WJ,Robinovitch SN

    更新日期:2011-02-03 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Preload substantially influences the intervertebral disc stiffness in loading-unloading cycles of compression.

    abstract::Disc hydration is controlled by fluid imbibition and exudation and hence by applied load magnitude and history, internal osmotic pressure and disc conditions. It affects both the internal load distribution and external load-bearing of a disc while variations therein give rise to the disc time-dependent characteristics...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.006

    authors: Schmidt H,Shirazi-Adl A,Schilling C,Dreischarf M

    更新日期:2016-06-14 00:00:00

  • Functional muscle synergies constrain force production during postural tasks.

    abstract::We recently demonstrated that a set of five functional muscle synergies were sufficient to characterize both hindlimb muscle activity and active forces during automatic postural responses in cats standing at multiple postural configurations. This characterization depended critically upon the assumption that the endpoi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.012

    authors: McKay JL,Ting LH

    更新日期:2008-01-01 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • Coupling between the spinal cord and cervical vertebral column under tensile loading.

    abstract::Current neck injury criteria are based on structural failure of the spinal (vertebral) column without consideration of injury to the spinal cord. Since one of the primary functions of the vertebral column is to protect the cord, it stands to reason that a more refined measure of neck injury threshold would be the onse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.012

    authors: Kroeker SG,Ching RP

    更新日期:2013-02-22 00:00:00

  • Compliance calibration for fracture testing of equine cortical bone.

    abstract::An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for cra...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00009-x

    authors: Malik CL,Gibeling JC,Martin RB,Stover SM

    更新日期:2002-05-01 00:00:00

  • Passive stress-strain relation for the right ventricle in diastole.

    abstract::Wall thickness and medial line radii of an in vitro canine heart are measured. These data are assumed to be characteristic of the in vivo ventricles subject to zero pressure, and in the absence of filling. The myocardium is taken to be homogeneous, isotropic, non-linearly elastic, and incompressible. The right ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90171-3

    authors: Moskowitz SE

    更新日期:1982-01-01 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • Effect of loss of balance on biomechanics platform measures of sway: influence of stance and a method for adjustment.

    abstract::This paper describes a method for adjusting biomechanics platform measures of sway for loss of balance. Area and velocity measures of sway were determined in forty-seven elderly women, in double and single leg stance, first with their eyes open, then closed. Subjects were rarely able to complete 10 s trials during sin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90025-x

    authors: Hasan SS,Lichtenstein MJ,Shiavi RG

    更新日期:1990-01-01 00:00:00